Digicom ED-20 PPP Dial IN/OUT, Connect at PWR on, Allowed values NO,YES Default no, DCD Control

Page 24

Dial IN/OUT

Select the operating mode of the ED-20. -Dial IN,

The unit will act as an PPP Server and only accept incoming calls. Modem Connect (Dial OUT) and the Brouter function will be disabled. -Dial IN/OUT,

The unit will act both as an PPP Server and an PPP Client.

When an incoming call is detected then the PPP Client is disabled.

–Dial OUT,

The unit will act as an PPP Client and not accept incoming calls.

Modem Connect (Dial IN) and the function Connect at PWR on will be disabled.

Allowed values: Dial IN, Dial IN/OUT, Dial OUT

Default: Dial IN/OUT

Connect at PWR on

Selects if the ED-20 shall establish a connection at Power on or not.

In PSTN mode the ED-20 will dial up using the command string defined in Modem Connect (Dial OUT) and when the modem link is ready, Establish the PPP link.

In LL Mode the ED-20 will establish the PPP link. This function is disabled in Dial IN mode.

Allowed values: NO,YES

Default: NO

DCD Control

When the signal DCD is lost the ED-20 will close the PPP link and when PSTN mode is selected the AT commands for Modem hangup and Modem init will be sent to the modem.

This function requires a special cable.

Allowed values: NO,YES

Default: NO

TD-XX

ED-20

TD-XX

ED-20

With 9-pos. female

With 9-pos. female

With 25-pos. female

With 9-pos. female

DCE connection

DCE connection

DCE connection

DCE connection

 

 

 

 

 

 

 

 

 

 

 

2

 

 

3

 

 

3

 

 

3

 

 

 

 

 

 

3

 

 

2

 

 

2

 

 

2

 

 

 

 

 

 

8

 

 

7

 

 

5

 

 

7

 

 

 

 

 

 

7

 

 

8

 

 

4

 

 

8

 

 

 

 

 

 

4

 

 

6

 

 

20

 

 

6

 

 

 

 

 

 

5

 

 

5

 

 

7

 

 

5

 

 

 

 

 

 

1

 

 

4

 

 

8

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9-pos. female

9-pos. female

25-pos. female

9-pos. female

24

6609-2221

Image 24
Contents PPP 6609-2221Contents Safety Before installation, maintenance or modification workInstallation ApprovalsDeclaration of conformity Declaration of ConformityIntroduction Specification Configuration Indicators LEDTransient Protection ApplicationMaintenance InstallationMounting /Removal Connections Out Transmitted DataReceived Data CH1 RS-232 Connections, DCE CH2 RS-232 Connections, DCELED Indicators From left to right PowerED-20 working mode Transmitted Data incoming serial dataFactory settings DIP Switch SettingsDIP Swiches is not used in this product, leave as it is Installation of ED-Tool for ED-20 MAC addressSystem Requirements MinimumApplication mode Functional descriptionAbout PPP Network interfacesConfiguration mode PPP connectionBrouter function Firewall functionConfiguration Configuration by ED-Tool for ED-20Typical configuration procedures Program StartED-Tool for ED-20 commands General commandsSerial Interface Channel 1 specific commands Selects type of connection, Serial or over the NetworkModem Settings Modem AT-Commands 16 17 18 Modem InitModem Hangup Modem Connect Dial OutNetwork Settings LoginPassword Set the login password PPP Network InterfaceBrouter Settings Brouter ModeBrouter Settings Firewall Settings Firewall ModeFirewall Settings IP AddressDefault 57 600 bit/s Allowed values None, RTS/CTS Default RTS/CTSAllowed values LL, Pstn Default Pstn Allowed valuesAllowed values NO,YES Default no Dial IN/OUTConnect at PWR on DCD ControlDefault +++ Default 2 secondsAllowed values, 0, 1 to Default 0 function disabled Default AT&F&D0S0=0&K3+MS=V34&WDefault ATH Default ConnectDefault Ring Default ATA Allowed values DefaultAllowed values NONE, PAP, Chap Default None Username0.0126.0.0.0 128.1.0.0 192.0.1.0 Default Local IPRemote address Subnet MaskRefer to .2.2 General Modem settings and Dial IN/OUT Default OffBrouter Settings IP Address Firewall Settings IP AddressExample of application with IP address settings Application examplesRemote connection LAN Dial LAN LAN Leased LineLAN LAN PSTN, Brouter, Firewall T03-03766609-222103.06 Mälartryck AB, Eskilstuna, Sweden

ED-20 PPP specifications

The Digicom ED-20 PPP is a sophisticated and versatile device designed to provide seamless communication solutions for both personal and professional use. As a cutting-edge platform for Point-to-Point Protocol (PPP), the ED-20 facilitates efficient data transmission over various communication networks, enhancing connectivity while ensuring security and reliability.

One of the main features of the Digicom ED-20 PPP is its robust support for multiple network technologies, including ISDN, dial-up, and broadband connections. This flexibility allows users to connect seamlessly to the internet or private networks, adapting to various scenarios and ensuring that they remain connected regardless of the circumstances. The ED-20's capability to support diverse communication methods makes it an ideal choice for businesses and individuals who require reliable data access.

The ED-20 excels in providing efficient data compression and error correction mechanisms. By employing advanced algorithms, it minimizes data payloads and enhances the speed of transmission. This feature is particularly beneficial for environments with limited bandwidth, as it allows users to optimize their data usage without sacrificing performance. The device’s ability to maintain high-speed communication even in challenging conditions highlights its technological prowess and adaptability.

Another hallmark of the Digicom ED-20 PPP is its easy-to-use interface and setup process. Designed with user experience in mind, the device requires minimal technical knowledge to configure and operate. This user-friendly approach ensures that even those unfamiliar with network technologies can benefit from its advanced features without a steep learning curve.

Security is paramount in today’s digital landscape, and the ED-20 PPP incorporates multiple security protocols to safeguard data transmission. By utilizing encryption and authentication techniques, the device ensures that sensitive information remains protected during transfer, making it an indispensable tool for organizations handling confidential data.

In terms of physical characteristics, the Digicom ED-20 PPP is compact and designed for portability, making it suitable for a variety of environments, including remote work settings and traveling professionals. Its durable construction guarantees longevity, while its lightweight design enhances mobility.

Overall, the Digicom ED-20 PPP stands out as a reliable and feature-rich solution for diverse communication needs, combining flexibility, efficiency, and security in a single device. Whether for business or personal use, the ED-20 effectively meets the demands of modern connectivity.