Answer

Command that will answer the incoming call.

Default: ATA

Timeout

Define the time in seconds, For how long time the ED-20 will accept incoming calls from power-up. Normally not used, leave as is.

Allowed values: 0-9999

Default: 0

8.2.3 Network Settings

Login

The login username and password is used on the dial-in connection and when the ED-20 is configured with ED-Tool for ED-20 over a network connection.

Authentication

Select if authentication shall be used over the PPP link or not.

Authentication can be used with either the PAP (Password Authentication Protocol) or CHAP protocols (Challenge Handshake Authentication Protocol)

If a invalid Username or password is entered the ED-20 will disconnect the PPP link and cause the modem to disconnect.

Allowed values: NONE, PAP, CHAP

Default: NONE

Username

Allowed string length: 1 – 19 characters.

Allowed characters:‘0’ to ‘9’,‘a’ to ‘z’ lower case.

Default: ed20

Password

Allowed string length: 1 – 19 characters.

Allowed characters:‘0’ to ‘9’,‘a’ to ‘z’ lower case.

Default: ed20

6609-2221

27

Image 27
Contents 6609-2221 PPPContents Approvals SafetyBefore installation, maintenance or modification work InstallationDeclaration of Conformity Declaration of conformityIntroduction Specification Application ConfigurationIndicators LED Transient ProtectionMaintenance InstallationMounting /Removal Connections Out Transmitted DataReceived Data CH2 RS-232 Connections, DCE CH1 RS-232 Connections, DCETransmitted Data incoming serial data LED Indicators From left to rightPower ED-20 working modeFactory settings DIP Switch SettingsDIP Swiches is not used in this product, leave as it is Minimum Installation of ED-Tool for ED-20MAC address System RequirementsNetwork interfaces Application modeFunctional description About PPPFirewall function Configuration modePPP connection Brouter functionProgram Start ConfigurationConfiguration by ED-Tool for ED-20 Typical configuration proceduresSelects type of connection, Serial or over the Network ED-Tool for ED-20 commandsGeneral commands Serial Interface Channel 1 specific commandsModem Settings Modem Connect Dial Out Modem AT-Commands16 17 18 Modem Init Modem HangupPPP Network Interface Network SettingsLogin Password Set the login passwordBrouter Settings Brouter ModeBrouter Settings IP Address Firewall SettingsFirewall Mode Firewall SettingsAllowed values Default 57 600 bit/sAllowed values None, RTS/CTS Default RTS/CTS Allowed values LL, Pstn Default PstnDCD Control Allowed values NO,YES Default noDial IN/OUT Connect at PWR onDefault AT&F&D0S0=0&K3+MS=V34&W Default +++Default 2 seconds Allowed values, 0, 1 to Default 0 function disabledDefault ATH Default ConnectDefault Ring Username Default ATAAllowed values Default Allowed values NONE, PAP, Chap Default NoneSubnet Mask 0.0126.0.0.0 128.1.0.0 192.0.1.0 DefaultLocal IP Remote addressFirewall Settings IP Address Refer to .2.2 General Modem settings and Dial IN/OUTDefault Off Brouter Settings IP AddressLAN LAN Leased Line Example of application with IP address settingsApplication examples Remote connection LAN DialLAN LAN PSTN, Brouter, Firewall T03-03766609-222103.06 Mälartryck AB, Eskilstuna, Sweden

ED-20 PPP specifications

The Digicom ED-20 PPP is a sophisticated and versatile device designed to provide seamless communication solutions for both personal and professional use. As a cutting-edge platform for Point-to-Point Protocol (PPP), the ED-20 facilitates efficient data transmission over various communication networks, enhancing connectivity while ensuring security and reliability.

One of the main features of the Digicom ED-20 PPP is its robust support for multiple network technologies, including ISDN, dial-up, and broadband connections. This flexibility allows users to connect seamlessly to the internet or private networks, adapting to various scenarios and ensuring that they remain connected regardless of the circumstances. The ED-20's capability to support diverse communication methods makes it an ideal choice for businesses and individuals who require reliable data access.

The ED-20 excels in providing efficient data compression and error correction mechanisms. By employing advanced algorithms, it minimizes data payloads and enhances the speed of transmission. This feature is particularly beneficial for environments with limited bandwidth, as it allows users to optimize their data usage without sacrificing performance. The device’s ability to maintain high-speed communication even in challenging conditions highlights its technological prowess and adaptability.

Another hallmark of the Digicom ED-20 PPP is its easy-to-use interface and setup process. Designed with user experience in mind, the device requires minimal technical knowledge to configure and operate. This user-friendly approach ensures that even those unfamiliar with network technologies can benefit from its advanced features without a steep learning curve.

Security is paramount in today’s digital landscape, and the ED-20 PPP incorporates multiple security protocols to safeguard data transmission. By utilizing encryption and authentication techniques, the device ensures that sensitive information remains protected during transfer, making it an indispensable tool for organizations handling confidential data.

In terms of physical characteristics, the Digicom ED-20 PPP is compact and designed for portability, making it suitable for a variety of environments, including remote work settings and traveling professionals. Its durable construction guarantees longevity, while its lightweight design enhances mobility.

Overall, the Digicom ED-20 PPP stands out as a reliable and feature-rich solution for diverse communication needs, combining flexibility, efficiency, and security in a single device. Whether for business or personal use, the ED-20 effectively meets the demands of modern connectivity.