Digicom ED-20 PPP PPP connection, Brouter function, Firewall function, Configuration mode

Page 15

7.1.2.2 PPP connection

The PPP connection can be established over PSTN, Leased Line or private lines.

ED-20 can act as a PPP Server, PPP Client or both.These functions is set on the ‘Modem settings’ tab in ED-Tool for ED-20. See application example on page 30.

Connections can be established in several ways depending on the application:

Standard PPP dial-up networking tool.

‘Connect’ command on CH2: or via TELNET

Using the ‘Brouter’ function.

7.1.2.3 Brouter function

The Brouter function will establish a dial-up connection when valid outbound IP address (Defined on the tab ‘Brouter Settings’ in ED-Tool for Ed-20) is sent to the ED-20.

See application example on page 31.

The connection will be open until one of following is true:

There is no traffic during and the ‘Idle Time’ parameter is set to a value greater than zero.

e.g. Idle Time is set to 600s and there is no traffic sent to the ED-20 for more than 10 minutes.

‘Close’ command on CH2: or via TELNET

Note! It may be wise to use the Firewall function while the Brouter function being used to reduce the traffic over the PPP link.

7.1.2.4 Firewall function

The Firewall function can be set-up to allow or block certain IP Addresses through the ED-20. See application example on page 31.

7.2 Configuration mode

Local or remote configuration is managed by ED-Tool for ED-20.

ED-Tool for ED-20 is a Windows based set-up programme which provides easy configuration.

Configuration is possible locally by using serial connection and remote using network (telnet) connection. Configuration mode will be entered automatically by ED-Tool for ED-20. ’Config ’ LED will lit when ED-20 is in configuration mode. (The unit is not in configuration mode until the ‘Write config’ button been pushed.)

The unit will be in configuration mode until a reboot is made.

First time configure: ED-20 is shipped with IP-address 169.254.100.100.

Please make sure that 169.254.100.100 is compliant to your network, before ED-20 is connected. Otherwise use serial interface to locally set a valid IP address compliant with the network in use and not chosen arbitrarily, ask your network administrator when in doubt.

6609-2221

15

Image 15
Contents 6609-2221 PPPContents Approvals SafetyBefore installation, maintenance or modification work InstallationDeclaration of Conformity Declaration of conformityIntroduction Specification Application ConfigurationIndicators LED Transient ProtectionMaintenance InstallationMounting /Removal Connections Out Transmitted DataReceived Data CH2 RS-232 Connections, DCE CH1 RS-232 Connections, DCETransmitted Data incoming serial data LED Indicators From left to rightPower ED-20 working modeFactory settings DIP Switch SettingsDIP Swiches is not used in this product, leave as it is Minimum Installation of ED-Tool for ED-20MAC address System RequirementsNetwork interfaces Application modeFunctional description About PPPFirewall function Configuration modePPP connection Brouter functionProgram Start ConfigurationConfiguration by ED-Tool for ED-20 Typical configuration proceduresSelects type of connection, Serial or over the Network ED-Tool for ED-20 commandsGeneral commands Serial Interface Channel 1 specific commandsModem Settings Modem Connect Dial Out Modem AT-Commands16 17 18 Modem Init Modem HangupPPP Network Interface Network SettingsLogin Password Set the login passwordBrouter Settings Brouter ModeBrouter Settings IP Address Firewall SettingsFirewall Mode Firewall SettingsAllowed values Default 57 600 bit/sAllowed values None, RTS/CTS Default RTS/CTS Allowed values LL, Pstn Default PstnDCD Control Allowed values NO,YES Default noDial IN/OUT Connect at PWR onDefault AT&F&D0S0=0&K3+MS=V34&W Default +++Default 2 seconds Allowed values, 0, 1 to Default 0 function disabledDefault ATH Default ConnectDefault Ring Username Default ATAAllowed values Default Allowed values NONE, PAP, Chap Default NoneSubnet Mask 0.0126.0.0.0 128.1.0.0 192.0.1.0 DefaultLocal IP Remote addressFirewall Settings IP Address Refer to .2.2 General Modem settings and Dial IN/OUTDefault Off Brouter Settings IP AddressLAN LAN Leased Line Example of application with IP address settingsApplication examples Remote connection LAN DialLAN LAN PSTN, Brouter, Firewall T03-03766609-222103.06 Mälartryck AB, Eskilstuna, Sweden

ED-20 PPP specifications

The Digicom ED-20 PPP is a sophisticated and versatile device designed to provide seamless communication solutions for both personal and professional use. As a cutting-edge platform for Point-to-Point Protocol (PPP), the ED-20 facilitates efficient data transmission over various communication networks, enhancing connectivity while ensuring security and reliability.

One of the main features of the Digicom ED-20 PPP is its robust support for multiple network technologies, including ISDN, dial-up, and broadband connections. This flexibility allows users to connect seamlessly to the internet or private networks, adapting to various scenarios and ensuring that they remain connected regardless of the circumstances. The ED-20's capability to support diverse communication methods makes it an ideal choice for businesses and individuals who require reliable data access.

The ED-20 excels in providing efficient data compression and error correction mechanisms. By employing advanced algorithms, it minimizes data payloads and enhances the speed of transmission. This feature is particularly beneficial for environments with limited bandwidth, as it allows users to optimize their data usage without sacrificing performance. The device’s ability to maintain high-speed communication even in challenging conditions highlights its technological prowess and adaptability.

Another hallmark of the Digicom ED-20 PPP is its easy-to-use interface and setup process. Designed with user experience in mind, the device requires minimal technical knowledge to configure and operate. This user-friendly approach ensures that even those unfamiliar with network technologies can benefit from its advanced features without a steep learning curve.

Security is paramount in today’s digital landscape, and the ED-20 PPP incorporates multiple security protocols to safeguard data transmission. By utilizing encryption and authentication techniques, the device ensures that sensitive information remains protected during transfer, making it an indispensable tool for organizations handling confidential data.

In terms of physical characteristics, the Digicom ED-20 PPP is compact and designed for portability, making it suitable for a variety of environments, including remote work settings and traveling professionals. Its durable construction guarantees longevity, while its lightweight design enhances mobility.

Overall, the Digicom ED-20 PPP stands out as a reliable and feature-rich solution for diverse communication needs, combining flexibility, efficiency, and security in a single device. Whether for business or personal use, the ED-20 effectively meets the demands of modern connectivity.