Digicom ED-20 PPP Refer to .2.2 General Modem settings and Dial IN/OUT, Default Off

Page 29

8.2.4 Brouter settings

The brouter function will initiate outgoing connections. This function is only available in PSTN + Dial Out mode

(Refer to section 8.2.2 – General – Modem settings and Dial IN/OUT.)

When a IP packet sent to the ED-20 have a IP Address that match a IP Address in the entry list, the ED-20 will send the connect message to the attached modem.This will result in an connection to another location and establishment of a PPP link.

Note! Since the ED-20 and the attached modems need some time to establish a modem connection and a PPP link,The IP packets sent before the PPP link is ready may be lost depending of the application used.

Brouter Mode

Enable or disable the brouter function with the radio buttons.

Note! The brouter function can only be enabled when the ED-20 is allowed to act as a PPP client. (Refer to section 8.2.2 – General – Dial IN/OUT.)

Default: Off

Brouter Settings

IP Address

Allowed values: Should be in decimal dotted notation and in another Network ID than the Local IP Address of the ED-20.

(Refer to section 8.2.3 – Ethernet Interface – Local IP Address)

Connect Message

This message will establish the modem connection. Allowed values: Is decided by the attached modem.

Note! Refer to the user guide or installation manual to the attached modem.

8.2.5 Firewall settings

The firewall function will allow the network administrator to control the network access and limit the traffic on the PPP link. It’s possible to accomplish this in two modes.

-Pass,Will only allow traffic where the source and destination IP address is present in the entry list.

-Block,Will block traffic where either source or destination is present in the entry list. See application exampes on page 31.

Firewall Mode

Disables or enables the Firewall mode with the radio buttons.

And selects if the firewall shall work in Block or Pass mode.

Default: Off

Firewall Settings

IP Address

Allowed values: Should be in decimal dotted notation and in another Network ID than the Local IP Address of the ED-20.

(Refer to section 8.2.3 – Ethernet Interface – Local IP Address)

6609-2221

29

Image 29
Contents 6609-2221 PPPContents Before installation, maintenance or modification work SafetyInstallation ApprovalsDeclaration of Conformity Declaration of conformityIntroduction Specification Indicators LED ConfigurationTransient Protection ApplicationMounting /Removal MaintenanceInstallation Received Data ConnectionsOut Transmitted Data CH2 RS-232 Connections, DCE CH1 RS-232 Connections, DCEPower LED Indicators From left to rightED-20 working mode Transmitted Data incoming serial dataDIP Swiches is not used in this product, leave as it is Factory settingsDIP Switch Settings MAC address Installation of ED-Tool for ED-20System Requirements MinimumFunctional description Application modeAbout PPP Network interfacesPPP connection Configuration modeBrouter function Firewall functionConfiguration by ED-Tool for ED-20 ConfigurationTypical configuration procedures Program StartGeneral commands ED-Tool for ED-20 commandsSerial Interface Channel 1 specific commands Selects type of connection, Serial or over the NetworkModem Settings 16 17 18 Modem Init Modem AT-CommandsModem Hangup Modem Connect Dial OutLogin Network SettingsPassword Set the login password PPP Network InterfaceBrouter Settings Brouter SettingsBrouter Mode Firewall Mode Firewall SettingsFirewall Settings IP AddressAllowed values None, RTS/CTS Default RTS/CTS Default 57 600 bit/sAllowed values LL, Pstn Default Pstn Allowed valuesDial IN/OUT Allowed values NO,YES Default noConnect at PWR on DCD ControlDefault 2 seconds Default +++Allowed values, 0, 1 to Default 0 function disabled Default AT&F&D0S0=0&K3+MS=V34&WDefault Ring Default ATHDefault Connect Allowed values Default Default ATAAllowed values NONE, PAP, Chap Default None UsernameLocal IP 0.0126.0.0.0 128.1.0.0 192.0.1.0 DefaultRemote address Subnet MaskDefault Off Refer to .2.2 General Modem settings and Dial IN/OUTBrouter Settings IP Address Firewall Settings IP AddressApplication examples Example of application with IP address settingsRemote connection LAN Dial LAN LAN Leased LineLAN LAN PSTN, Brouter, Firewall T03-03766609-222103.06 Mälartryck AB, Eskilstuna, Sweden

ED-20 PPP specifications

The Digicom ED-20 PPP is a sophisticated and versatile device designed to provide seamless communication solutions for both personal and professional use. As a cutting-edge platform for Point-to-Point Protocol (PPP), the ED-20 facilitates efficient data transmission over various communication networks, enhancing connectivity while ensuring security and reliability.

One of the main features of the Digicom ED-20 PPP is its robust support for multiple network technologies, including ISDN, dial-up, and broadband connections. This flexibility allows users to connect seamlessly to the internet or private networks, adapting to various scenarios and ensuring that they remain connected regardless of the circumstances. The ED-20's capability to support diverse communication methods makes it an ideal choice for businesses and individuals who require reliable data access.

The ED-20 excels in providing efficient data compression and error correction mechanisms. By employing advanced algorithms, it minimizes data payloads and enhances the speed of transmission. This feature is particularly beneficial for environments with limited bandwidth, as it allows users to optimize their data usage without sacrificing performance. The device’s ability to maintain high-speed communication even in challenging conditions highlights its technological prowess and adaptability.

Another hallmark of the Digicom ED-20 PPP is its easy-to-use interface and setup process. Designed with user experience in mind, the device requires minimal technical knowledge to configure and operate. This user-friendly approach ensures that even those unfamiliar with network technologies can benefit from its advanced features without a steep learning curve.

Security is paramount in today’s digital landscape, and the ED-20 PPP incorporates multiple security protocols to safeguard data transmission. By utilizing encryption and authentication techniques, the device ensures that sensitive information remains protected during transfer, making it an indispensable tool for organizations handling confidential data.

In terms of physical characteristics, the Digicom ED-20 PPP is compact and designed for portability, making it suitable for a variety of environments, including remote work settings and traveling professionals. Its durable construction guarantees longevity, while its lightweight design enhances mobility.

Overall, the Digicom ED-20 PPP stands out as a reliable and feature-rich solution for diverse communication needs, combining flexibility, efficiency, and security in a single device. Whether for business or personal use, the ED-20 effectively meets the demands of modern connectivity.