Eaton Electrical 34003991EN/EB Appendices, Tables of alarms and events, Table of alarms

Page 106

8 Appendices

8.1Tables of alarms and events

8.1.1 Table of alarms

List of time dated alarms

Alarm on

Battery fuse blown

No Battery

Battery temperature fault

Battery charger fault

Battery fault

MAX charger voltage fault

MIN charger voltage fault

Charger temperature fault

Rectifier fault

Chopper fault

Normal AC frequency out of tolerance Normal AC fuses blown

Normal AC module fault

Normal AC voltage out of tolerance Normal AC NOK

Site wiring fault

Bypass AC frequency out of tolerance Bypass AC phase out of tolerance Bypass AC voltage out of tolerance Automatic Bypass fault

Automatic Bypass overload Automatic Bypass overtemperature Automatic Bypass thermal overload Automatic Bypass switch (Q4S) open Normal AC switch (Q1) open Battery switch (QF1) open

Manual Bypass switch (Q3BP) closed UPS on manual bypass

Output switch (Q5N) open

Single wave load fault

Negative DC bus too high

Positive DC bus too high

Negative DC bus too low

Positive DC bus too low

Inverter limitation

Inverter fuses blown

Inverter fault

Alarm off

Battery fuse OK

Battery present

Battery temperature OK

Battery charger OK

Battery OK

Charger voltage OK

Charger voltage OK

Charger temperature OK

Rectifier OK

Chopper OK

Normal AC frequency OK

Normal AC fuses OK

Normal AC module OK

Normal AC voltage OK

Normal AC OK

Site wiring OK

Bypass AC frequency OK Bypass AC phase OK Bypass AC voltage OK Automatic Bypass OK Automatic Bypass load OK Automatic Bypass temperature OK Automatic Bypass load OK Automatic Bypass switch (Q4S) closed Normal AC switch (Q1) closed Battery switch (QF1) closed

Manual Bypass switch (Q3BP) open

Output switch (Q5N) closed

Load OK

Negative DC bus OK

Positive DC bus OK

Negative DC bus OK

Positive DC bus OK

Inverter end of limitation

Input fuses OK

Inverter OK

Network Management Card – User Manual

34003991EN/EB

Page 106/118

Image 106
Contents Network Management Card Contents Server Protection Configuration VIA RS232Industrial Network Management Card Inmc Option MGE MIB Jbus TableAppendices GlossaryEaton Network Solution General PresentationConnecting the UPS to the Ethernet network Protection of the computers/serversSupervision of the UPSs over the network ConnectionPresentation of the Network Management Card NMC How to connect UPS / agent / networkSetting up the protection Compatibility with UPSsSending text messages SMS Direct sending of E-mailEnvironment Sensor option Configuration Technical dataHardware characteristics EMC CompatibilityEnvironment sensor AdministrationNetwork List of ports usedMIB Management Information Base Default parameters BOOTP/DHCPUnpacking and check on contents InstallationIndications LED Installation in the UPSACT Sensor installation option Configure IP parameters ConfigurationEaton Network Management Card Your network is equipped with a Dhcp server Test after configuration Your network is not equipped with a Dhcp serverSupervision and administration by browser Optimising the performance of your browserUPS UPS propertiesUPS zone general information on the UPS 23/118 24/118 25/118 26/118 UPS status zone Essential information Viewing the modules 29/118 Viewing the alarms Alarm table for modular UPS Viewing the About your UPS window On-line help UPS control 35/118 36/118 UPS weekly schedule programming Shutdown parameters For the main outlet Master by default Measurements Event log System log Notification Email Notification44/118 Mail Message Settings 46/118 Configuration Network settings 49/118 System 51/118 Notified Applications 53/118 Central shutdown configuration Access control 55/118TLS Date and time 58/118 Firmware upload Characteristics Environment Sensor optionEnvironment Status Environment Settings Display in the list of current alarms 4 Log Set-up of the shutdown parameters Server protectionShutdown criteria managed by the Network Management Card Utility failure Start of the shutdown sequence Shutdown when backup time is less than Shutdown durationProtection of a server connected to a controlled outlet Controlled outletsLoad shedding or sequential shutdown Different server and UPS shutdown sequences Sequential startup70/118 Shutdown management with 2 NMC boards SettingsShutdown Duration Configuration via RS232 Choice 2 Network Configuration Choice 1 Restart / ResetChoice 1 Read Network settings Choice 2 Modify Network settings Choice 3 Set Ethernet speedChoice 3 Lost password / Set Login Password to Default Choice 4 Return to Default Configuration Presentation Industrial Network Management Card Inmc optionOverview Functions Technical characteristics JBUS/MODBUSInstallation 1 RS232 link configuration and connection2 RS485 link configuration and connection 2.1 RS485 connection81/118 2.2 RS485 link configuration for 2 wires connexion 83/118 2.3 RS485 link configuration for 4 wires connexion 85/118 Configuration of the JBUS/MODBUS communication parameters Choice 1 Display Jbus settings Choice 2 Modify Jbus settingsChoice 4 Reset Jbus diagnostics Choice 3 Display Jbus diagnosticsChoice 5 Return to Jbus Default Configuration Choice 6 Display Jbus frames Additional Web pages Data for Pulsar 700 / 1000 Jbus tableStatus table Measurements table Data for Pulsar M 2200 94/118 Data for Pulsar MX 4000 / 5000 / 10000 and EX 5 / 7 / 11 RT 96/118 Data for Pulsar MX frame 15 Modular fault table 99/118 100/118 101/118 Sensor data 5.1 Status table103/118 Read of the personalization table Other data Table of alarms Tables of alarms and eventsAppendices UPS OK If the UPS is modular UPS, for each module Table of UPS events 110/118 Table of system alarms Snmp objects MGE MIB113/118 1yes 2no 1,4,1 Table des Traps MIB Trap116/118 MIB Management Information Base GlossaryNetwork Management Proxy Snmp Simple Network Management Protocol NMS Network Management Station SnmpNSM Network Shutdown Module Smtp Simple Mail Transfer Protocol