Lyngdorf Audio TDA 2200 owner manual c. Focus Measurement

Page 25
c. Focus Measurement

c. Focus Measurement

When the calibration is OK, press enter to start the measuring process and the following message will be displayed. Each measurement comprises four steps: a low and a high frequency measuring signal first in the left and then in the right channel. The length of each measurement depends on a combination of the measurement volume, set in the calibration process, and the background noise in your local environment. Typical measuring times for the low and high frequency measuring signals are 25 and 5 seconds, respectively. As mentioned, the measuring signals sound artificial and disharmonic due to the fact that they are made up of pure tones at different frequencies. It is advised that you do not to sit in the listening position during this measurement.

The measurement will stop prematurely if an error occurs during the measuring process. In this case, the error message is displayed. Press enter to continue and the following is displayed.

If the error needs correcting this should be done at this point (see RoomPerfect™ troubleshooting), thereafter press enter to retry the measurement. The measurement procedure will start again.

A measurement has ended successfully when the last measuring signal stops and the display shows a RoomKnowledge rating, as in the following.

Press enter to continue.

Do not sit in the listening position during focus measurements.

25

Image 25
Contents RoomPerfect Page Table of Contents RoomPerfect Advanced Menu i.Exclamation symbol a. Explanation of graphical symbolsii.Lightning symbol 1. WARNINGSb. Important safety instructions 2. Unpacking the TDA a. Accessoriesb. Operating Voltage 3.Product Registration4. Introduction a. Controls 5. Front PanelFig 1 TDA 2200 front panel b. Display Indicators Fig 2 TDA 2200 rear panel 6. Rear Panel7. Remote Control 8. Menu System b. Voicing a. RoomPerfectc. Crossover d. Delay f. Communication e. ADC Level - Otionalg. Trigger Set-up h. Remote Controli. Display j. Volume k. Advanced set-up 9. RoomPerfect a. The Guided Set-up- a Quick Guide Fig 3 Measurement of main listening position b. Setting the measurement volume levelPage c. Focus Measurement d. Room Measurements e.Adding more room measurements f.Calculation of Focus 1 and Global Filters a. Selected Position 10. RoomPerfect Advanced Menub. Adding a New Focus Position Press enter to continue c. Adding a New Room Position e. RoomCorrection Index d. RoomKnowledge Indexa. Global Listening 11.Daily Use of RoomPerfectb. Focus Listening b. Fault - No signal 12. RoomPerfect Troubleshootinga. No microphone connected d. Fault - Low signal c. Fault - Signal clipping13. Software Fig 5 Software Upgrade Toola. Mains Connector 14. Connectorsb. Loudspeaker Connectors c. Trigger connector 16. Cleaning and Maintenance15. Optional AD Converter Board a. Balanced inputsParameter 17. Technical Specifications a. AudioValue c. Mains b. Protectiond. Trigger e. Mechanicala. Support 18. Technical AssistanceLyngdorf Audio a. Menu Tree 19. AppendixSoft b. Voicing CurvesOpen Desharp1