Lyngdorf Audio TDA 2200 Optional AD Converter Board, Cleaning and Maintenance, a. Balanced inputs

Page 38
15. Optional AD Converter Board

15. Optional AD Converter Board

The Optional AD Converter card for the TDA 2200 has input connectors for both balanced (XLR) and unbalanced (RCA) signals. The input impedance of the inputs are 10 kOhm.

a. Balanced inputs

The balanced XLR inputs are wired in accordance with IEC268:

Pin 1: Chassis and ground.

Pin 2: Hot (+).

Pin 3: Cold (-).

Shell: Chassis and ground.

b. Unbalanced inputs

The unbalanced RCA inputs are wired in accordance with normal practice:

Shell: Chassis and ground.

Pin: Hot (+).

c. Trigger connector

The TDA 2200 is equipped with a TRIGGER OUT 3.5mm mono jack connector. The Trigger signal is a 12V short circuit-protected output signal for powering up external equipment when the TDA 2200 is on, e.g. remotely connected SDA 2175 power amplifiers or active subwoofers.

16. Cleaning and Maintenance

Always unplug the unit from the electrical outlet before cleaning.

This unit does not require any regular maintenance except to keep its exterior clean. Simply wipe its exterior with a clean soft cloth. A small amount of non-abrasive cleaner may be used on the cloth to remove any excessive dirt or fingerprints. Do not use abrasive cleaners or cleaners containing liquid solvents.

38

Image 38
Contents RoomPerfect Page Table of Contents RoomPerfect Advanced Menu ii.Lightning symbol a. Explanation of graphical symbolsi.Exclamation symbol 1. WARNINGSb. Important safety instructions a. Accessories 2. Unpacking the TDA3.Product Registration b. Operating Voltage4. Introduction Fig 1 TDA 2200 front panel 5. Front Panela. Controls b. Display Indicators 6. Rear Panel Fig 2 TDA 2200 rear panel7. Remote Control 8. Menu System c. Crossover a. RoomPerfectb. Voicing d. Delay e. ADC Level - Otional f. Communicationi. Display h. Remote Controlg. Trigger Set-up j. Volume k. Advanced set-up 9. RoomPerfect a. The Guided Set-up- a Quick Guide b. Setting the measurement volume level Fig 3 Measurement of main listening positionPage c. Focus Measurement d. Room Measurements e.Adding more room measurements f.Calculation of Focus 1 and Global Filters b. Adding a New Focus Position 10. RoomPerfect Advanced Menua. Selected Position Press enter to continue c. Adding a New Room Position d. RoomKnowledge Index e. RoomCorrection Indexb. Focus Listening 11.Daily Use of RoomPerfecta. Global Listening a. No microphone connected 12. RoomPerfect Troubleshootingb. Fault - No signal c. Fault - Signal clipping d. Fault - Low signalFig 5 Software Upgrade Tool 13. Softwareb. Loudspeaker Connectors 14. Connectorsa. Mains Connector 15. Optional AD Converter Board 16. Cleaning and Maintenancec. Trigger connector a. Balanced inputsValue 17. Technical Specifications a. AudioParameter d. Trigger b. Protectionc. Mains e. MechanicalLyngdorf Audio 18. Technical Assistancea. Support 19. Appendix a. Menu TreeOpen b. Voicing CurvesSoft Desharp1