Cypress CY7C1332AV25, CY7C1330AV25 manual Maximum Ratings, Operating Range, Ambient Range

Page 13

CY7C1330AV25

PRELIMINARYCY7C1332AV25

Maximum Ratings

(Above which the useful life may be impaired. For user guide- lines, not tested.)

Storage Temperature

–65°C to +150°C

Ambient Temperature with

 

 

 

Power Applied

–55°C to +125°°C

Supply Voltage on VDD Relative to GND

–0.5V to +2.9V

Supply Voltage on VDDQ Relative to GND

–0.5V to +VDD

DC Voltage Applied to Outputs

 

 

 

in High-Z State[7]

–0.5V to V

+ 0.5V

 

 

DDQ

 

DC Input Voltage[7]

–0.5V to VDD + 0.5V

Current into Outputs (LOW)

 

20 mA

Static Discharge Voltage

 

> 1500V

(per MIL-STD-883, Method 3015)

 

Latch-up Current

 

> 200 mA

Operating Range

 

 

 

 

 

 

 

Ambient

 

 

Range

Temperature

VDD

VDDQ

Com’l

0°C to +70°C

2.37V to 2.63V

1.4V to 1.9V

 

 

 

 

Electrical Characteristics Over the Operating Range

DC Electrical Characteristics Over the Operating Range

Parameter

Description

 

 

Test Conditions

 

Min.

Max.

Unit

VDD

Power Supply Voltage

 

 

 

 

 

2.37

2.63

V

VDDQ

I/O Supply Voltage

 

 

 

 

 

1.4

1.9

V

VOH1

Output HIGH Voltage[12]

Programmable Impedance Mode[14]

VDDQ/2

VDD

V

V

OL1

Output LOW Voltage[13]

Programmable Impedance Mode[14]

V

V /2

V

 

 

 

 

 

 

 

SS

DDQ

 

VOH2

Output HIGH Voltage

IOH = –0.1 mA, Minimum Impedance Mode[15]

VDDQ – 0.2

VDDQ

V

V

OL2

Output LOW Voltage

I

OL

= 0.1 mA, Minimum Impedance Mode[15]

V

0.2

V

 

 

 

 

 

 

SS

 

 

VOH3

Output HIGH Voltage

IOH = –6.0 mA, Minimum Impedance Mode[15]

VDDQ – 0.4

VDDQ

V

V

OL3

Output LOW Voltage

I

OL

= 6.0 mA, Minimum Impedance Mode[15]

V

0.4

V

 

 

 

 

 

 

SS

 

 

VIH

Input HIGH Voltage

 

 

 

 

 

VREF + 0.1

VDDQ + 0.3

V

VIL

Input LOW Voltage[7]

 

 

 

 

 

–0.3

VREF – 0.1

V

IX

Input Leakage Current

GND VI VDDQ

 

–1

1

mA

IOZ

Output Leakage Current

GND VI VDDQ, Output Disabled

 

–1

1

mA

VREF

Input Reference Voltage

Typical value = 0.75V

 

0.68

0.95

V

VIN–CLK

Clock Input Reference

 

 

 

 

 

–0.3

VDDQ + 0.3

V

 

 

Voltage

 

 

 

 

 

 

 

 

VDIF–CLK

Clock Input Differential

 

 

 

 

 

0.1

VDDQ + 0.3

V

 

 

Voltage

 

 

 

 

 

 

 

 

VCM–CLK

Clock Common Mode

Typical Value =0.75V

 

0.55

0.95

V

 

 

Voltage

 

 

 

 

 

 

 

 

IDD

VDD Operating Supply

VDD = Max., IOUT = 0 mA,

 

250 MHz

 

600

mA

 

 

 

f = fMAX = 1/tCYC

 

 

 

 

 

 

 

 

 

200 MHz

 

550

mA

ISB1

Automatic CE

Max. VDD, Device Deselected,

 

250 MHz

 

280

mA

 

 

Power-Down

VIN > VIH or VIN < VIL

 

 

 

 

 

 

 

 

200 MHz

 

260

mA

 

 

Current—TTL Inputs

f = fMAX = 1/tCYC

 

 

 

 

 

AC Electrical Characteristics Over the Operating Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Description

 

 

Test Conditions

 

Min.

Max.

Unit

 

 

 

 

 

 

 

 

 

 

VIH

Input HIGH Voltage

 

 

 

 

 

VREF + 0.2

V

VIL

Input LOW Voltage

 

 

 

 

 

VREF – 0.2

V

Notes:

12.IOH = (VDDQ/2)/(RQ/5)+15% for 175< RQ < 350.

13.IOL = (VDDQ/2)/(RQ/5)+15% for 175< RQ < 350.

14.Programmable Impedance Output Buffer Mode. The ZQ pin is connected to VSS through RQ.

15.Minimum Impedance Output Buffer Mode: The ZQ pin is connected directly to VSS or VDD.

16.TPower-up: Assumes a linear ramp from 0V to VDD (min.) within 200 ms. During this time VIH < VDD and VDDQ < VDD.

Document No: 001-07844 Rev. *A

Page 13 of 19

[+] Feedback

Image 13
Contents Configuration FeaturesLogic Block Diagram Functional DescriptionMaximum Access Time Maximum Operating Current Pin Configurations Ball BGA 14 x 22 x 2.4 mmSelection Guide UnitName Type Description Pin DefinitionsByte Write Select Inputs, active LOW. Qualified with Serial clock to the Jtag circuit No connectsIntroduction Sleep ModeFunctional Overview Cycle Description Truth , 2, 3, 4 ZZ Mode Electrical CharacteristicsWrite Cycle Descriptions 1 Write Cycle Descriptions1Ieee 1149.1 Serial Boundary Scan Jtag Extest EXIT2-IR UPDATE-DR UPDATE-IR TAP Controller State Diagram6TAP Electrical Characteristics Over the Operating Range7, 8 TAP Controller Block DiagramParameter Description Min Max Unit Set-up TimesIdentification Register Definitions TAP Timing and Test Conditions11Parameter Description Min Output TimesInstruction Codes Scan Register SizesBoundary Scan Order 1 Mbit x Boundary Scan Order 512K x Maximum Ratings Electrical Characteristics Over the Operating RangeOperating Range Ambient RangeThermal Resistance17 Capacitance17AC Test Loads and Waveforms Parameter Description Test Conditions Max Unit250 200 Parameter Description Unit Min Max Switching Characteristics 18, 19, 20Clock READ/WRITE/DESELECT Sequence OE Controlled23, 24, 25 Switching Waveforms= DON’T Care = Undefined Originally Deselected READ/WRITE/DESELECT Sequence CE ControlledOrdering Information Package DiagramBall Pbga 14 x 22 x 2.4 mm New data sheet ECN No Issue Date Orig. Description of ChangeMinor change Moved data sheet to web Document History