Bay Technical Associates RM356 manual Tcp/Ip

Page 118

T

TCP Estab field, TCP/IP Filter Rule menu 8-6

TCP/IP

configuration, testing 9-6 configuring 7-1

network, troubleshooting 10-2Protocol 9-7

requirements 2-4 tools 9-7

using with LAN-to-LAN 7-1

TCP/IP field, System Maintenance - Diagnostic menu 9-6

TCP/IP Filter Rule menu 8-4

TCP/IP Setup field, Ethernet Setup menu 3-10

Telco Options field

Default Dial-in Setup 6-2

Remote Node Profile menu 5-3

telephone line checklist 2-2

Telnet session, connecting to manager interface 2-9

terminal baud rate 9-3

Total Outcall Time field, System Maintenance Status menu 9-2

trace display 9-7

trace tools 9-3

troubleshooting 10-1

TX Pkts field, System Maintenance Status menu 9-2

6

U

UNIX system, using to configure 1-4,2-9,3-1 User Name field, Edit Dial-in User 6-4

V

Value field, Generic Filter Rule menu 8-7

W

WAN Menus, manager interface 3-7 WAN port, setting up 3-7 warranty 1-3

Windows 95, unneccessary calls 8-9 World Wide Web iv

X

XMODEM Protocol 9-9

Index

Image 118
Contents Reference Guide for the Model RM356 Modem Router NETGEAR, IncStatement of Conditions TrademarksEN 55 022 Declaration of Conformance VCCI-2 Statement Bestätigung des Herstellers/ImporteursCertificate of the Manufacturer/Importer Customer SupportWorld Wide Web Contents Chapter Router Installation and Connection Chapter Remote Node Configuration Chapter System Maintenance Appendix a Technical Specifications Index Contents Figures Xii Tables System Maintenance Syslog and Accounting Menu Fields Purpose PrefaceAudience Special Message Formats ConventionsUse of Enter, Type, and Press Related Publications Other ConventionsPage Chapter Introduction FeaturesAbout the Router Key Features Support TCP/IP SupportSecurity Management SupportBasic Router Concepts What is a Router?Routing Information Protocol IP Addresses and the Internet Three Main Address Classes Netmask Subnet Addressing Example of Subnetting a Class B AddressNetmask Notation Translation Table for One Octet Number of Bits Dotted-Decimal ValueNetmask Formats Private IP AddressesDotted-Decimal Mask-length Single IP Address Operation Using NAT Single IP Address Operation Using NATAddress Resolution Protocol Domain Name ServerIP Configuration by Dhcp Chapter Router Installation and Connection Package ContentsTelephone Line Checklist ChecklistsISP Checklist Single-User Account Network Checklist Connecting the Router Front Panel of the Model RM356 Modem RouterLED Descriptions Label Activity DescriptionConnecting the Serial Cable Optional Connecting to the Line PortConnecting a Telephone, Fax, or Modem Connecting to the Hub PortsConnecting the Power Adapter Connecting for Configuration Connecting Through the Serial PortConnecting Through a Telnet Connection Chapter Router Configuration Configuration MethodsPowering on the Router Start-up DisplayNavigating the Manager Manager Menu CommandsAction Description Manager Main Menu is illustrated in Figure Manager Menu Summary Manager Menu SummaryNumber Menu Title Description General Setup Menu Menu 1 General SetupModem Menus Modem Setup MenuModem Setup Menu Parameters Field Description ExampleAdvanced Modem Setup Menu Field Descriptions Advanced Modem Setup MenuField Description Default Ethernet Menu General Setup MenuEthernet General Setup Menu Filter Sets Field DescriptionDhcp and TCP/IP Setup Menu 3 Ethernet Setup Menu FieldsRIP Direction Manager Password Setup Chapter Configuration for Internet Access Information ChecklistInternet Access Configuration Configuration for Single-User Account Configuring for a Backup ISP Backup ISP AccountsSwitching to a Backup ISP Chapter Remote Node Configuration Menu 11.1 Remote Node Profile Fields PPP Options on Editing PPP Options Fields in Menu 11.2 Remote Node PPP OptionsScript Options Display Editing Script OptionsField Description Option Page Chapter Dial-In Configuration Default Dial-In SetupFields in Menu 13 Default Dial-in Setup Dial-In User Setup Fields in Menu 14.1 Edit Dial-in User More On Clid Page Chapter TCP/IP Configuration LAN-to-LAN ApplicationRemote Node Setup Fields in Menu 11.1 Remote Node Profile FieldsMenu 11.3 Remote Node Network Layer Options Fields Static Route Setup RIPEdit IP Static Route Menu Fields Page Chapter Filter Configuration Outgoing Packet Filtering ProcessConfiguring a Filter Set Router Filter StructureAbbreviations Used if Filter Type Is IP Abbreviations Used in Menu 21.1 Filter Rules SummaryAbbreviation Description TCP/IP Filter Rule Configuring a Filter RuleAbbreviations Used if Filter Type Is GEN TCP/IP Filter Rule Menu Fields IP ProtocolTCP Estab Generic Filter Rule Generic Filter Rule Menu FieldsApplying a Filter Set Reducing Unnecessary Calls by Windows Diagnosing the SituationReference Guide for the Model RM356 Modem Router Menu 21 Filter Set Configuration Implementing the FilterShows Menu 21.1.1 TCP/IP Filter Rule Filter Rules Summary Menu Applying the Filter Remote Node Profile MenuCommand Field Name Description Chapter System MaintenanceSystem Maintenance Status Menu Fields System StatusMake an outgoing call Terminal Baud Rate Log and TraceCommand Field View Error LogSystem Maintenance Log and Trace Menu Fields Syslog and AccountingSystem Maintenance Syslog and Accounting Menu Fields Field Command DescriptionDiagnostic Menu System Maintenance Diagnostic Menu FieldsCall Testing and TCP/IP Tools Trace Display for a Successful TCP/IP Protocol ConnectionSystem Tools Trace Display for a Failed TCP/IP Protocol ConnectionRestore Configuration Back Up ConfigurationSoftware Update Command Interpreter Mode Call ControlBudget Management BlacklistCall History Page Basic Functioning Chapter TroubleshootingLAN Link LED Troubleshooting a TCP/IP Network Using a Ping Utility Testing the LAN Path to Your RouterTesting the Path from Your PC to a Remote Device Troubleshooting a Remote Node or ISP Connection Troubleshooting a Remote User ConnectionTroubleshooting the Manager Interface Restoring the Default Configuration and Password Using the Packet and Log Trace Trace the callPacket Trace Display Format Packet Trace Display DefinitionsAppendix a Technical Specifications General SpecificationInterface Specifications Physical SpecificationsEnvironmental Specifications Electromagnetic EmissionsIndex Dhcp Index Index Index TCP/IP

RM356 specifications

Bay Technical Associates RM356 is a state-of-the-art remote monitoring solution designed for a wide range of industries. It is particularly suited for companies requiring a reliable system for tracking and monitoring operations in real-time. This advanced device combines innovative technologies to deliver unparalleled functionality and performance.

One of the standout features of the RM356 is its robust data acquisition capabilities. The device can interface with various sensors and equipment, enabling it to collect critical data from multiple sources. This real-time data collection allows for immediate analysis and facilitates informed decision-making. The RM356 supports various protocols and standards, making it highly compatible with existing infrastructure.

Another significant characteristic of the RM356 is its advanced communication technology. Equipped with both wired and wireless communication options, including LTE, Wi-Fi, and Ethernet, it ensures seamless connectivity in various environments. This versatility enables businesses to monitor operations remotely, reducing the need for on-site presence and enhancing operational efficiency.

The RM356 also incorporates cutting-edge analytics and reporting tools. Its built-in software allows users to visualize data through intuitive dashboards, making it easier to identify trends and anomalies. These analytics capabilities help organizations optimize processes and address potential issues before they escalate, ultimately improving productivity and reducing operational costs.

Security is a top priority for the RM356. The unit comes with robust encryption and authentication measures to ensure that the data it collects remains secure from unauthorized access. This feature is especially critical for industries handling sensitive information or operating in regulated environments.

Additionally, the RM356 is designed with user-friendliness in mind. Its installation process is straightforward, with comprehensive setup guides available for quick deployment. Once operational, users can easily navigate the system interface, allowing for efficient monitoring and management of their operations.

With its combination of advanced features, reliable communication, data analytics, and strict security measures, Bay Technical Associates RM356 stands out as an excellent choice for businesses looking to enhance their monitoring capabilities. Whether in manufacturing, logistics, energy, or other sectors, the RM356 is poised to deliver improved outcomes and support organizations in their quest for operational excellence.