Bay Technical Associates RM356 Private IP Addresses, Netmask Formats, Dotted-Decimal Mask-length

Page 29

Reference Guide for the Model RM356 Modem Router

Table 1-2 displays several common netmask values in both the dotted-decimal and the mask-length formats.

Table 1-2. Netmask Formats

Dotted-Decimal Mask-length

255.0.0.0/8

255.255.0.0/16

255.255.255.0/24

255.255.255.128 /25

255.255.255.192 /26

255.255.255.224 /27

255.255.255.240 /28

255.255.255.248 /29

255.255.255.252 /30

255.255.255.254 /31

255.255.255.255 /32

NETGEAR strongly advises that all hosts on a LAN segment use the same netmask for the following reasons:

So that hosts recognize local IP broadcast packets

When a device broadcasts to its segment neighbors, it uses a destination address of the local network address with all ones for the host address. In order for this scheme to work, all devices on the segment must agree on which bits comprise the host address.

So that a local router or bridge will know which addresses are local and which are remote

Private IP Addresses

If your networks are isolated from the Internet (for example, only between your two branch offices), you can assign any IP addresses to the hosts without problems. However, the IANA has reserved the following three blocks of IP addresses specifically for private networks:

10.0.0.0- 10.255.255.255

172.16.0.0- 172.31.255.255

192.168.0.0 - 192.168.255.255

NETGEAR recommends that you choose your private network number from this list.

Introduction

1-11

Image 29
Contents NETGEAR, Inc Reference Guide for the Model RM356 Modem RouterEN 55 022 Declaration of Conformance TrademarksStatement of Conditions Certificate of the Manufacturer/Importer Bestätigung des Herstellers/ImporteursVCCI-2 Statement Customer SupportWorld Wide Web Contents Chapter Router Installation and Connection Chapter Remote Node Configuration Chapter System Maintenance Appendix a Technical Specifications Index Contents Figures Xii Tables System Maintenance Syslog and Accounting Menu Fields Audience PrefacePurpose Use of Enter, Type, and Press ConventionsSpecial Message Formats Other Conventions Related PublicationsPage About the Router FeaturesChapter Introduction Key Features TCP/IP Support SupportManagement Support SecurityRouting Information Protocol What is a Router?Basic Router Concepts IP Addresses and the Internet Three Main Address Classes Netmask Example of Subnetting a Class B Address Subnet AddressingNumber of Bits Dotted-Decimal Value Netmask Notation Translation Table for One OctetDotted-Decimal Mask-length Private IP AddressesNetmask Formats Single IP Address Operation Using NAT Single IP Address Operation Using NATDomain Name Server Address Resolution ProtocolIP Configuration by Dhcp Package Contents Chapter Router Installation and ConnectionISP Checklist ChecklistsTelephone Line Checklist Single-User Account Network Checklist Front Panel of the Model RM356 Modem Router Connecting the RouterLabel Activity Description LED DescriptionsConnecting to the Line Port Connecting the Serial Cable OptionalConnecting the Power Adapter Connecting to the Hub PortsConnecting a Telephone, Fax, or Modem Connecting Through the Serial Port Connecting for ConfigurationConnecting Through a Telnet Connection Configuration Methods Chapter Router ConfigurationStart-up Display Powering on the RouterAction Description Manager Menu CommandsNavigating the Manager Manager Main Menu is illustrated in Figure Number Menu Title Description Manager Menu SummaryManager Menu Summary Menu 1 General Setup General Setup MenuModem Setup Menu Parameters Modem Setup MenuModem Menus Field Description ExampleField Description Default Advanced Modem Setup MenuAdvanced Modem Setup Menu Field Descriptions Ethernet General Setup Menu Filter Sets General Setup MenuEthernet Menu Field DescriptionMenu 3 Ethernet Setup Menu Fields Dhcp and TCP/IP SetupRIP Direction Manager Password Setup Information Checklist Chapter Configuration for Internet AccessInternet Access Configuration Configuration for Single-User Account Switching to a Backup ISP Backup ISP AccountsConfiguring for a Backup ISP Chapter Remote Node Configuration Menu 11.1 Remote Node Profile Fields PPP Options on Fields in Menu 11.2 Remote Node PPP Options Editing PPP OptionsField Description Option Editing Script OptionsScript Options Display Page Default Dial-In Setup Chapter Dial-In ConfigurationFields in Menu 13 Default Dial-in Setup Dial-In User Setup Fields in Menu 14.1 Edit Dial-in User More On Clid Page LAN-to-LAN Application Chapter TCP/IP ConfigurationFields in Menu 11.1 Remote Node Profile Fields Remote Node SetupMenu 11.3 Remote Node Network Layer Options Fields RIP Static Route SetupEdit IP Static Route Menu Fields Page Outgoing Packet Filtering Process Chapter Filter ConfigurationRouter Filter Structure Configuring a Filter SetAbbreviation Description Abbreviations Used in Menu 21.1 Filter Rules SummaryAbbreviations Used if Filter Type Is IP Abbreviations Used if Filter Type Is GEN Configuring a Filter RuleTCP/IP Filter Rule IP Protocol TCP/IP Filter Rule Menu FieldsTCP Estab Generic Filter Rule Menu Fields Generic Filter RuleApplying a Filter Set Diagnosing the Situation Reducing Unnecessary Calls by WindowsReference Guide for the Model RM356 Modem Router Implementing the Filter Menu 21 Filter Set ConfigurationShows Menu 21.1.1 TCP/IP Filter Rule Filter Rules Summary Menu Remote Node Profile Menu Applying the FilterSystem Maintenance Status Menu Fields Chapter System MaintenanceCommand Field Name Description System StatusMake an outgoing call Log and Trace Terminal Baud RateSystem Maintenance Log and Trace Menu Fields View Error LogCommand Field Syslog and AccountingField Command Description System Maintenance Syslog and Accounting Menu FieldsSystem Maintenance Diagnostic Menu Fields Diagnostic MenuTrace Display for a Successful TCP/IP Protocol Connection Call Testing and TCP/IP ToolsTrace Display for a Failed TCP/IP Protocol Connection System ToolsSoftware Update Back Up ConfigurationRestore Configuration Call Control Command Interpreter ModeCall History BlacklistBudget Management Page LAN Link LED Chapter TroubleshootingBasic Functioning Testing the LAN Path to Your Router Troubleshooting a TCP/IP Network Using a Ping UtilityTesting the Path from Your PC to a Remote Device Troubleshooting a Remote User Connection Troubleshooting a Remote Node or ISP ConnectionTroubleshooting the Manager Interface Restoring the Default Configuration and Password Trace the call Using the Packet and Log TracePacket Trace Display Definitions Packet Trace Display FormatGeneral Specification Appendix a Technical SpecificationsEnvironmental Specifications Physical SpecificationsInterface Specifications Electromagnetic EmissionsIndex Dhcp Index Index Index TCP/IP

RM356 specifications

Bay Technical Associates RM356 is a state-of-the-art remote monitoring solution designed for a wide range of industries. It is particularly suited for companies requiring a reliable system for tracking and monitoring operations in real-time. This advanced device combines innovative technologies to deliver unparalleled functionality and performance.

One of the standout features of the RM356 is its robust data acquisition capabilities. The device can interface with various sensors and equipment, enabling it to collect critical data from multiple sources. This real-time data collection allows for immediate analysis and facilitates informed decision-making. The RM356 supports various protocols and standards, making it highly compatible with existing infrastructure.

Another significant characteristic of the RM356 is its advanced communication technology. Equipped with both wired and wireless communication options, including LTE, Wi-Fi, and Ethernet, it ensures seamless connectivity in various environments. This versatility enables businesses to monitor operations remotely, reducing the need for on-site presence and enhancing operational efficiency.

The RM356 also incorporates cutting-edge analytics and reporting tools. Its built-in software allows users to visualize data through intuitive dashboards, making it easier to identify trends and anomalies. These analytics capabilities help organizations optimize processes and address potential issues before they escalate, ultimately improving productivity and reducing operational costs.

Security is a top priority for the RM356. The unit comes with robust encryption and authentication measures to ensure that the data it collects remains secure from unauthorized access. This feature is especially critical for industries handling sensitive information or operating in regulated environments.

Additionally, the RM356 is designed with user-friendliness in mind. Its installation process is straightforward, with comprehensive setup guides available for quick deployment. Once operational, users can easily navigate the system interface, allowing for efficient monitoring and management of their operations.

With its combination of advanced features, reliable communication, data analytics, and strict security measures, Bay Technical Associates RM356 stands out as an excellent choice for businesses looking to enhance their monitoring capabilities. Whether in manufacturing, logistics, energy, or other sectors, the RM356 is poised to deliver improved outcomes and support organizations in their quest for operational excellence.