Bay Technical Associates RM356 manual Configuring a Filter Rule, TCP/IP Filter Rule

Page 80

Reference Guide for the Model RM356 Modem Router

If the filter type is GEN (generic), the abbreviations listed in Table 8-3 are used.

Table 8-3.

Abbreviations Used if Filter Type Is GEN

 

 

Abbreviation

Description

 

 

Off

Offset

 

 

Len

Length

 

 

To configure a specific filter rule, select the number of the filter rule (1–6) that you want to configure and press [Enter] to display Menu 21.1.1 - TCP/IP Filter Rule.

Configuring a Filter Rule

You can configure two types of filter rules. Some of the parameters differ depending on the type of rule. When you first enter the filter rule menu, Menu 21.1.1 - TCP/IP Filter Rule is displayed. If you want to configure a generic type of filter rule, select Generic by pressing the space bar under the Filter Type field and then pressing [Enter] to display the menu for a generic filter rule.

TCP/IP Filter Rule

This section provides information about how to configure a TCP/IP filter rule for your router. The fields in the menu are given in Table 8-4. When you have completed Menu 21.1.1 - TCP/IP Filter Rule, press [Enter] at the Press ENTER to Confirm...prompt to confirm your selections. You can press [Esc] at any time to cancel your selections. The data you entered on

Menu 21.1.1 - TCP/IP Filter Rule is displayed on Menu 21.1 - Filter Rules Summary.

Table 8-4 lists and describes the TCP/IP Filter Rule menu fields and a description of each field.

8-4

Filter Configuration

Image 80
Contents Reference Guide for the Model RM356 Modem Router NETGEAR, IncEN 55 022 Declaration of Conformance TrademarksStatement of Conditions Bestätigung des Herstellers/Importeurs Certificate of the Manufacturer/ImporterVCCI-2 Statement Customer SupportWorld Wide Web Contents Chapter Router Installation and Connection Chapter Remote Node Configuration Chapter System Maintenance Appendix a Technical Specifications Index Contents Figures Xii Tables System Maintenance Syslog and Accounting Menu Fields Audience PrefacePurpose Use of Enter, Type, and Press ConventionsSpecial Message Formats Related Publications Other ConventionsPage About the Router FeaturesChapter Introduction Key Features Support TCP/IP SupportSecurity Management SupportRouting Information Protocol What is a Router?Basic Router Concepts IP Addresses and the Internet Three Main Address Classes Netmask Subnet Addressing Example of Subnetting a Class B AddressNetmask Notation Translation Table for One Octet Number of Bits Dotted-Decimal ValueDotted-Decimal Mask-length Private IP AddressesNetmask Formats Single IP Address Operation Using NAT Single IP Address Operation Using NATAddress Resolution Protocol Domain Name ServerIP Configuration by Dhcp Chapter Router Installation and Connection Package ContentsISP Checklist ChecklistsTelephone Line Checklist Single-User Account Network Checklist Connecting the Router Front Panel of the Model RM356 Modem RouterLED Descriptions Label Activity DescriptionConnecting the Serial Cable Optional Connecting to the Line PortConnecting the Power Adapter Connecting to the Hub PortsConnecting a Telephone, Fax, or Modem Connecting for Configuration Connecting Through the Serial PortConnecting Through a Telnet Connection Chapter Router Configuration Configuration MethodsPowering on the Router Start-up DisplayAction Description Manager Menu CommandsNavigating the Manager Manager Main Menu is illustrated in Figure Number Menu Title Description Manager Menu SummaryManager Menu Summary General Setup Menu Menu 1 General SetupModem Setup Menu Modem Setup Menu ParametersModem Menus Field Description ExampleField Description Default Advanced Modem Setup MenuAdvanced Modem Setup Menu Field Descriptions General Setup Menu Ethernet General Setup Menu Filter SetsEthernet Menu Field DescriptionDhcp and TCP/IP Setup Menu 3 Ethernet Setup Menu FieldsRIP Direction Manager Password Setup Chapter Configuration for Internet Access Information ChecklistInternet Access Configuration Configuration for Single-User Account Switching to a Backup ISP Backup ISP AccountsConfiguring for a Backup ISP Chapter Remote Node Configuration Menu 11.1 Remote Node Profile Fields PPP Options on Editing PPP Options Fields in Menu 11.2 Remote Node PPP OptionsField Description Option Editing Script OptionsScript Options Display Page Chapter Dial-In Configuration Default Dial-In SetupFields in Menu 13 Default Dial-in Setup Dial-In User Setup Fields in Menu 14.1 Edit Dial-in User More On Clid Page Chapter TCP/IP Configuration LAN-to-LAN ApplicationRemote Node Setup Fields in Menu 11.1 Remote Node Profile FieldsMenu 11.3 Remote Node Network Layer Options Fields Static Route Setup RIPEdit IP Static Route Menu Fields Page Chapter Filter Configuration Outgoing Packet Filtering ProcessConfiguring a Filter Set Router Filter StructureAbbreviation Description Abbreviations Used in Menu 21.1 Filter Rules SummaryAbbreviations Used if Filter Type Is IP Abbreviations Used if Filter Type Is GEN Configuring a Filter RuleTCP/IP Filter Rule TCP/IP Filter Rule Menu Fields IP ProtocolTCP Estab Generic Filter Rule Generic Filter Rule Menu FieldsApplying a Filter Set Reducing Unnecessary Calls by Windows Diagnosing the SituationReference Guide for the Model RM356 Modem Router Menu 21 Filter Set Configuration Implementing the FilterShows Menu 21.1.1 TCP/IP Filter Rule Filter Rules Summary Menu Applying the Filter Remote Node Profile MenuChapter System Maintenance System Maintenance Status Menu FieldsCommand Field Name Description System StatusMake an outgoing call Terminal Baud Rate Log and TraceView Error Log System Maintenance Log and Trace Menu FieldsCommand Field Syslog and AccountingSystem Maintenance Syslog and Accounting Menu Fields Field Command DescriptionDiagnostic Menu System Maintenance Diagnostic Menu FieldsCall Testing and TCP/IP Tools Trace Display for a Successful TCP/IP Protocol ConnectionSystem Tools Trace Display for a Failed TCP/IP Protocol ConnectionSoftware Update Back Up ConfigurationRestore Configuration Command Interpreter Mode Call ControlCall History BlacklistBudget Management Page LAN Link LED Chapter TroubleshootingBasic Functioning Troubleshooting a TCP/IP Network Using a Ping Utility Testing the LAN Path to Your RouterTesting the Path from Your PC to a Remote Device Troubleshooting a Remote Node or ISP Connection Troubleshooting a Remote User ConnectionTroubleshooting the Manager Interface Restoring the Default Configuration and Password Using the Packet and Log Trace Trace the callPacket Trace Display Format Packet Trace Display DefinitionsAppendix a Technical Specifications General SpecificationPhysical Specifications Environmental SpecificationsInterface Specifications Electromagnetic EmissionsIndex Dhcp Index Index Index TCP/IP

RM356 specifications

Bay Technical Associates RM356 is a state-of-the-art remote monitoring solution designed for a wide range of industries. It is particularly suited for companies requiring a reliable system for tracking and monitoring operations in real-time. This advanced device combines innovative technologies to deliver unparalleled functionality and performance.

One of the standout features of the RM356 is its robust data acquisition capabilities. The device can interface with various sensors and equipment, enabling it to collect critical data from multiple sources. This real-time data collection allows for immediate analysis and facilitates informed decision-making. The RM356 supports various protocols and standards, making it highly compatible with existing infrastructure.

Another significant characteristic of the RM356 is its advanced communication technology. Equipped with both wired and wireless communication options, including LTE, Wi-Fi, and Ethernet, it ensures seamless connectivity in various environments. This versatility enables businesses to monitor operations remotely, reducing the need for on-site presence and enhancing operational efficiency.

The RM356 also incorporates cutting-edge analytics and reporting tools. Its built-in software allows users to visualize data through intuitive dashboards, making it easier to identify trends and anomalies. These analytics capabilities help organizations optimize processes and address potential issues before they escalate, ultimately improving productivity and reducing operational costs.

Security is a top priority for the RM356. The unit comes with robust encryption and authentication measures to ensure that the data it collects remains secure from unauthorized access. This feature is especially critical for industries handling sensitive information or operating in regulated environments.

Additionally, the RM356 is designed with user-friendliness in mind. Its installation process is straightforward, with comprehensive setup guides available for quick deployment. Once operational, users can easily navigate the system interface, allowing for efficient monitoring and management of their operations.

With its combination of advanced features, reliable communication, data analytics, and strict security measures, Bay Technical Associates RM356 stands out as an excellent choice for businesses looking to enhance their monitoring capabilities. Whether in manufacturing, logistics, energy, or other sectors, the RM356 is poised to deliver improved outcomes and support organizations in their quest for operational excellence.