The pole mount kit can be used to secure the mount to a pole with diameter from 2.0 to 4.5 inches (50 to 115 mm). Listed below are the steps required to assemble the bracket for a pole mount application:

1.Pre-assemble the pole mount brackets by attaching the 4 All-Thread rods to two of the pole mount brackets using eight ⅜-16 x ¾ hex nuts and four each ⅜ split lock washers, and ⅜ # 8 flat washers, as shown in Figure 3-4. This creates a U-Bolt type arrangement.

Figure 3-4 Pole-Mount Bracket Assembly

The ⅜-16 x ¾ hex nuts on the inside of the pole clamps do not require any washers since they are only holding the threaded rods in place and do not bear any load. These hex nuts secure the All Thread rods to the pole clamps making it easier to align the clamps on each side of the pole.

2.Attach two pole mount brackets to the wall-mounting bracket using 4 each ⅜-16 x ¾ bolts, ⅜ Split lock washers, and ⅜ # 8 flat washers.

13

590-00532, rev A

Image 18
Contents SLE100 Fast Ethernet Links Copyright Notice & Disclaimer Export ControlProduct Compatibility Safety Equipment Precautions Regulatory InformationTable of Contents Introduction Purpose of ManualPrior Knowledge Contact Information Technical Assistance and Customer ServiceReturn Material Authorization RMA BridgeWave SalesGeneral Equipment ChecklistSite Planning Line of Sight LOSAntenna Location CablingCabling Diagram Grounding & LightningEnvironmental Equipment Inventory InstallationEquipment Unpacking Qty DescriptionDescription Qty Installation Tools Radio Mount Installation Wall Mounting InstructionsAttaching the Yoke to the Mounting Bracket Wall Mount Hole Drilling Template Pole-Mount Bracket Assembly Pole Mounting InstructionsAttaching Pole Mount Brackets to Wall Mount Bracket Attaching Pole Mount Brackets and Yoke to Pole Radio Installation Polarization Diamond OrientationsAttaching the Radio to the Yoke Perform steps 1 -3 on both ends of the link Cable Installation SLE100 Installation Manual Optional Ice Shield Canopy Installation IntroductionInstallation Instructions Optional KitAttaching the Ice Shield Re-install the O bolt Antenna Alignment Ig h t MirrorWrong Qual & RSL Test Cable 11 RSL & Qual Test Leads12 RSL and Quality Test Cable Connection Point 14 Radio Link Up and Power LED’s Configuring Network Equipment Network Port StatisticsAppendix a Troubleshooting Problem Possible Cause ResolutionSLE100 Installation Manual Appendix B RSL Voltage vs. Distance Std. Limited Warranty & SW License Limited Hardware WarrantyLimitation of Remedy and Liability Provisions