BridgeWave SLE100 installation manual RSL and Quality Test Cable Connection Point

Page 33

TM

SLE100 Installation Manual

Figure 3-12: RSL and Quality Test Cable Connection Point

The voltmeter should be set to DC voltage and the x 20 setting. The expected RSL level is dependent on the distance between the two radio terminals. A chart is provided in Appendix B.

The quality voltage provides an indication of how well the link is performing and is described in the graph and detailed description below.

QUAL Voltage (VDC)

3.3

3.0 Correctable Errors Detected

NO

ERRORS

2.0

Uncorrectable Errors Detected

1.7

CORRECTED

ERRORS

UNCORRECTED

ERRORS

0.3

Deframer Unlocked (Link Down)

0.0

0

0

 

Errors

 

Figure 3-13 Quality Voltage Graph

Quality Voltages between 3.0V and 3.3V indicate an error-free wireless link.

Quality Voltages between 1.5V and 3.0V indicate a low rate of errors that the forward error correction will correct. The lower the voltage, the more errors are being corrected.

28

590-00532, rev A

Image 33
Contents SLE100 Fast Ethernet Links Copyright Notice & Disclaimer Export ControlProduct Compatibility Safety Regulatory Information Equipment PrecautionsTable of Contents Introduction Purpose of ManualPrior Knowledge Return Material Authorization RMA Technical Assistance and Customer ServiceContact Information BridgeWave SalesSite Planning Equipment ChecklistGeneral Line of Sight LOSCabling Antenna LocationGrounding & Lightning Cabling DiagramEnvironmental Equipment Unpacking InstallationEquipment Inventory Qty DescriptionDescription Qty Installation Tools Wall Mounting Instructions Radio Mount InstallationAttaching the Yoke to the Mounting Bracket Wall Mount Hole Drilling Template Pole Mounting Instructions Pole-Mount Bracket AssemblyAttaching Pole Mount Brackets to Wall Mount Bracket Attaching Pole Mount Brackets and Yoke to Pole Polarization Diamond Orientations Radio InstallationAttaching the Radio to the Yoke Perform steps 1 -3 on both ends of the link Cable Installation SLE100 Installation Manual Introduction Optional Ice Shield Canopy InstallationOptional Kit Installation InstructionsAttaching the Ice Shield Re-install the O bolt Antenna Alignment Mirror Ig h tWrong 11 RSL & Qual Test Leads Qual & RSL Test Cable12 RSL and Quality Test Cable Connection Point 14 Radio Link Up and Power LED’s Network Port Statistics Configuring Network EquipmentProblem Possible Cause Resolution Appendix a TroubleshootingSLE100 Installation Manual Appendix B RSL Voltage vs. Distance Limited Hardware Warranty Std. Limited Warranty & SW LicenseLimitation of Remedy and Liability Provisions