Zhone Technologies Network Device manual Data Diagnostics, Diagnostic Capabilities of Data Ports

Page 108

 

Zhone Technologies, Inc.

 

 

IMACS Product Book, Version 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quiet Tone

Yes

Yes

Yes

Yes

Yes

 

 

Digital MilliWatt

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

Tone Direction

 

 

 

 

 

 

 

Toward User

Yes

Yes

Yes

Yes

Yes

 

 

Toward Network

Yes

Yes

Yes

Yes

Yes

 

This feature is only supported in Cross-Connect Systems

Data Diagnostics

Data diagnostics support varies among data cards. Refer to Table 27 for detailed information on data card diagnostics. Generally, data card diagnostics supported include the setting of various levels of loop backs toward the network or the attached DTE equipment. Other support includes the ability to generate and respond to industry- standard loop-up and loop-down codes that are compatible with DDS, V.54 and/or Fractional T1 (FT1) formats. The DS0-DP data card generates and detects DS0-DP loop back codes.

Table 27—Diagnostic Capabilities of Data Ports

EIA530

HSU

2-port

V.35

HSU

2-port

EIA530/V.35 SRU HSU

4-port

OCU-DP DS0-DP 2/5/10-port 4-port

LOOP BACKS

On-Card Loop backs

 

EIA530

V.35

EIA530/V.35

SRU

OCU-DP

DS0-DP

 

HSU

HSU

HSU

 

2/5/10-port

4-port

 

2-port

2-port

4-port

 

 

 

Toward DTE

Yes

Yes

Yes

Yes

Yes

Yes

Toward Network

Yes

Yes

Yes

Yes

Yes

Yes

In-Band Loop back Code Generation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EIA530

V.35

EIA530/V.35

SRU

OCU-DP

DS0-DP

 

HSU

HSU

HSU

 

2/5/10-port

4-port

 

2-port

2-port

4-port

 

 

 

Latching DDS-OCU

Yes

Yes

Yes

Yes

Yes

Yes

Latching DDS-DSU

Yes

Yes

Yes

Yes

No

Yes

Latching DDS-CSU

Yes

Yes

Yes

Yes

Yes

Yes

Latching DDS-DS0

Yes

Yes

Yes

No

Yes

Yes

ITU (CCITT) V.54

Yes

Yes

Yes

No

No

No

ANSI Fractional T1 (FT1)

Yes

Yes

Yes

No

No

No

Control Lead Handling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EIA530

V.35

EIA530/V.35

SRU

OCU-DP

DS0-DP

 

HSU

HSU

HSU

 

2/5/10-port

4-port

 

2-port

2-port

4-port

 

 

 

Set CTS

Yes

Yes

Yes

Yes

N/A

N/A

Set RLSD

Yes

Yes

Yes

Yes

N/A

N/A

Set DSR

Yes

Yes

Yes

No

N/A

N/A

Monitor RTS

Yes

Yes

Yes

Yes

N/A

N/A

Monitor DTR

Yes

Yes

Yes

No

N/A

N/A

March 2001

Page 104

Image 108
Contents Imacs Product Book Intentionally Left Blank Table of Contents Imacs System Testing and Diagnostics Section Title Server CardsManagement Channel Concentrator MCC Internet Protocol Router Low-Bit Rate Voice ServerImacs Product Overview Imacs Features and Benefits Imacs Architecture Overview WANCPU WAN Imacs System Bus ArchitectureUser Buses WAN BusesServer Buses Card Type SummaryCPU Card Interface CardPower Supply Redundancy Voice CardData Card Server CardCPU Card Redundancy WAN Card RedundancyAdpcm Redundancy System Synchronization and ClockingImacs System Management MCC MIBFrame Relay NetworkImacs Management Using FDL/SA4 T1/E1 Frame RelayRouter FDL over ESF Each FDL is mapped to a separate DS0Imacs 38.4 kbps Slip Terminal Server Concentrator Node Page M card with 2713 Hz Loop back Module# Imacs 800 Universal Enclosure-Front View Imacs 800 Universal EnclosureImacs 800 Universal Enclosure-Rear View Imacs 900 Universal EnclosureImacs 900 Universal Enclosure Imacs 600 Front Load EnclosurePhysical and Environmental Characteristics Imacs Dimensions Chassis Height Width Depth ModelPower Supplies Imacs Minimum Clearances 600 800 900Imacs Compliance With Regulatory Standards Model 8903 Power Supply 120 VAC Model 8905 Power Supply, 120/240 VAC Model 8908 Power Supply, 105/240 VACRing Generator Page CPU Cards LED Indicators Operational ModesCode Storage Maximum number of WAN linksInterface Cards Page Interface Card Specifications YESWAN Ports Node Port EIA RS232-C DOC CS03Page T1 Signal Format E1 Signal FormatHDB3 Performance and Test OptionsWAN Card Hardware Specifications Etsi ETRSpecification Short Loop Long Loop Foreign Exchange Station FXS CardVF Transmission Characteristics Foreign Exchange Office FXO CardPCM Coding Transhybrid LossVF Transmission Characteristics M Card Delay Specification Phone Station and Office Line Cards Universal Imacs P-Phone ApplicationStatus Indicators Voice TransmissionSubscriber and Central Office Interface-Transmit Channel 2W Port Characteristics KHz Signaling SpecificationsSealing Current Source Sealing Current SinkVoice Channel Bank Application TR-008 ApplicationImacs Using TR-008 T1-E1 ConversionImacs Data Modules and Applications Data Card Types Type of Card DescriptionData Card Types Page HSU Card ApplicationsCAD/CAM Imacs and HSU Application ExamplePoint to MultiPoint One-Way Video and Audio Using HSUs Dial Capability Performance StatisticsSRU Card Imacs Signaling Synchronous DataAsynchronous Data Standards CompatibilityFrad Card Imacs w/ Frad Imacs Frad Card ApplicationFrad Card Specifications DiagnosticsModel 823160 Frad Card DlciOCU-DP Card OCU-DP Card ModelsPage OCU-DP Specifications Model Number Number of Ports Physical InterfacesBRI Card Imacs BRI Terminal Extension ApplicationImacs BRI Card In a Leased Line or Idsl Application BRI Card ModelsPage Remote NTU Configuration Options Procedural CharacteristicsModel 8262 manual settings Software Configurable OptionsBRI Card Specifications Off or On per port Models 826361 and 826171 onlyDesign Standards for Model Lult LuntImacs Using the 822860 For Network Management BnR IP Concentrator CardB7R IP Concentrator Card Specifications External Ports PortMaster Integrated Office Router PM-IOROptions port Internal PortsTechnical Specifications UDP, IcmpTCP/IP, IPX Alarm Cards Alarm Card Specifications Model 840160, 840260 Adpcm Voice Compression ServerPorts 840160 840260 840360 Model 8403 BuzzerPBX-to-PBX Trunk Application T1/E1Automatic Call Distribution Application BRI-U BRI-STImacs In a Wireless Base Station Application Wireless Base Station ApplicationAdpcm Server Card Specifications Isdn Primary Rate Interface PRI ServerNfas Non-Facility Associated Signaling Remote LoginSwitch 23B+D on T1 30B+D on E1 Customer 3 5B+D Fractional PRI ProvisioningCustomer 1 10B+D 7B+D Isdn Video Conferencing and Video BroadcastCodec Integrated Isdn Access with Sina Video T1/E1Video Data Backup and Bandwidth on Demand 25bis/DTRDialing Dialing RouterPRI to FXS Termination Routing Capabilities Call Routing Local RoutingSwitch DefaultBi-directional Default Routing Alternate RoutingManagement Channel Concentrator MCC Server Dpnss Trunk RoutingMCC In a Multilevel Concentration Application Frame Relay Server Specifications ACS-FRS Advanced Communication Server Frame Relay ServerFECN, Becn Frame Relay Access and Concentration Server Frame Relay Switch Port SavingsImacs Using Frame Relay Server Cards Frame Relay and Internet Service ProvisioningFrame Relay and Internet Services Using IMACS’ Frad Server Idsl Service ProvisioningIdsl Service Provisioning Grooming and Concentration in Cellular NetworksMobile Switch Office Channelized DS1s = 96 DS0s Frame SwitchMobile Base Station Frame Relay DS1sFrame Relay Concentration at Corporate Headquarters Legacy Adaptation to ATM Migrating Legacy Networks to ATM Interactive Distance Learning/Tele-MedicineATM Server Specifications Interactive Distance Learning ApplicationATM Server Card Specifications ATM I/FON/OFF CBR, VBRInternet Protocol Router Maximum Byte SizeSnmp Support Standards SupportUses of IPR Application Ethernet LANIPR-2 IPR-3Bundled Service Deployment Private Intranet DeploymentPrivate Intranet Deployment Using IP Routing Server Card IP Routing Server SpecificationsIP Routing Server Card Specifications UNI DCE, UNI DTE, NNIMTU Call Center Application Lbrv In a Call Center Application Backhauling Voice ApplicationExtending Voice Access Application Switch T1/E1Central VoiceMail Server T1/E1 NX64K Leased Line T1/E1Password Protection Letter MeaningImacs System Parameters Port Status SummaryImacs Diagnostic Capabilities Status and Alarm Management Integral Test CapabilitiesWAN Diagnostics Bit Error Rate Tester Bert Patterns SupportedIn-Band Loop back Code Generation In-Band Loop back Code DetectionVoice Diagnostics Diagnostic Capabilities of Voice PortsBert Direction Statistics Gathered By BertData Diagnostics Diagnostic Capabilities of Data PortsControl Lead Handling Systems Equipped With Cross-Connect Option DataSingaling 64Kbps Nx64Kbp Toward WAN1 Yes Toward WAN2Data Singaling 64Kbps Nx64KbpBert Direction Voice Single Data Super-rate Without Tones Supported Voice Single Data Super-rate WithoutBenefits of Built-In Diagnostics Toward WAN Voice Single Data Super-rate WithoutBuilt-In Diagnostics Example Imacs Performance Monitoring T1 Line Performance MonitoringDDS Line Performance Monitoring Frame Relay Performance MonitoringATM Performance Monitoring Conclusion