Zhone Technologies, Inc. | IMACS Product Book, Version 4 |
Models 8903, 8905 and 8908 power supplies provide
Table
Model 8901 AC Power Supply 120/240 AC |
|
Input Voltage | |
| 175 VAC to 264 VAC at 50 Hz |
Input Frequency | 47 to 63 Hz |
Inrush Surge Current | Max. 12 amp peak at 264 VAC cold start |
Output Power | 55W Continuous |
Maximum Number per system | 2 |
Redundancy | Optional |
Ventilation | Convection cooled |
Protection | Unit is fused and protected from short circuits and over- |
| voltage |
Approvals | UL 1459, EN 60950, |
Model 8902 DC Power Supply 48 VDC |
|
Input Voltage | |
Inrush Surge Current | Maximum 12 amp at 60VDC |
Output Power | 55 Watts Continuous |
Maximum Number per system | 2 |
Redundancy | Optional |
Ventilation | Convection cooled |
Protection | Unit is fused protected from short circuits and overage |
| Unit is diode protected from reversed polarity |
Approvals | UL 1459, EN60950, |
Model 8907 DC Power Supply 24 VDC, |
|
Input Voltage | 18 to 36 VDC |
Inrush Surge Current | Maximum 12 amp at 36 VDC |
Output Power: | 55 Watts Continuous |
Maximum Number per system | 2 |
Redundancy | Optional |
Ventilation | Convection cooled |
Protection | Unit is fuse protected from short circuits and |
| Unit is diode protected from reverse polarity |
Approvals | UL 1459, EN60950, |
Model 8903 Power Supply 120 VAC |
|
Input Voltage | 90VAC to 132 VAC |
Input Frequency | 60 Hz |
Inrush Surge Current | Max. 20amp peak at 132 VAC cold start |
Output Voltage | |
Maximum Number per system | 2 |
Redundancy | Optional |
Ventilation | Convection cooled |
Protection | Unit is fused and protected from short circuits and over- |
| voltage |
Approvals | UL 1459, UL 1950, |
March 2001 | Page 19 |