AVE VSI-Pro Max Display Text, Choices OFF, 1S, 5S, 10S, 20S, 30S, 1M, 5M, 10M, SET Triggered Text

Page 46

PROGRAMMING

DISPLAY TEXT

Choices: ON, OFF

Press the “Up” or “Down” button to move the cursor to “DISPLAY TEXT” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to cycle through the values and press “Set” when the desired value is displayed. Selecting “OFF” will not display any exception text on the video output.

OUTPUT TEXT

Choices: ON, OFF

Press the “Up” or “Down” button to move the cursor to “OUTPUT TEXT” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to cycle through the values and press “Set” when the desired value is displayed. Selecting “OFF” will not send any exception text to the serial printer.

RTS TRIGGERED DELAY

Choices: OFF, 1S, 5S, 10S, 20S, 30S, 1M, 5M, 10M

Press the “Up” or “Down” button to move the cursor to “RTS TRIGGERED DELAY” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to cycle through the values and press “Set” when the desired value is displayed. Selecting “OFF” will give no delay and will trigger the alarm immediately upon RTS closure..

This function introduces a time delay for the RTS Trigger Input before initiating an alarm condition. The alarm must be continuous for the entire time of the delay setting or the time out will be reset. This is useful to connector to cash drawers or safe doors and wait a programmable amount of time before sounding the alarm. Leaving cash drawers or safe doors open are indicative of theft or simple forgetfullness and an alarm condition will deter this behavior.

SET TRIGGERED TEXT

Press the “Up” or “Down” button to move the cursor to “SET TRIGGERED TEXT” and press “Set”. The following sub- menu will appear:

DISPLAY TEXT

OFF

OUTPUT TEXT

OFF

RTS TRIGGERED DELAY OFF

SET TRIGGERED TEXT

EXIT

Figure 75: Set Triggered Text Main-Menu

You can enter 2 lines with 40 alpha numeric text on each line. You can also enter non-printable data (control code) instead of triggered text. Each control code occupies 3 charactors, therefore you can enter 13 control codes in a line. To enter control code, first print up arrow ^ follwed by 2 hex digit. For example, hex code 01 has to be entered like ^ 01. Press “Up” and “Down” simultaneously to exit.

VIDEO LOSS

Choices: Manual, 1s, 2s, 3s, 4s, 5s, 10s, 20s, 30s, 1M

Video Loss allows the VSI-Pro Max to generate an alarm condition when low or lost video occurs. When set for manual the alarm follows the state of the video loss, when set for 1s-1M this means the video must be lost continuously for that period of time before an alarm is triggered. The alarm mode is a timed mode so once the video loss alarm is triggered the alarm time out must expire and get another video loss to retrigger the alarm.

EXIT

Press the “Up” or “Down” button to move the cursor to “EXIT” and press “Set” to return to the previous menu.

VSI-Pro Max POS / Cash Register Interface

46

Image 46
Contents VSI-PRO MAX SeptemberVSI-Pro Max Contents Figures Contents Register Select Sub-MenuRecerve RX Test Sub-Menu Introduction VSI / VSI+ / VSI-Pro / VSI-Pro Max Backward CompatibilityFeatures & Specifications FeaturesSpecifications DTR / DSRLED Indicators ConnectionsDSR PIN # Signal Name RS232DTR RTSPIN # Function Direction To Earth Ground for Surge SuppressionVideo Surge / Lightning Protection Grounding and IsolationRS-232 DB9F Shielding User Front Panel Controls Down Up Set ResetFront Panel Controls Changing the Horizontal Position Main Programming Menu ProgrammingGetting Started Register SelectNext page Exit TCP/IPTCP/IP Limitations Generic Model TK-T500 Mode Emulating ExitMode Emulating Exit Addressable VSI VSI-ADDPOS / CDU Nucleus Delta SonoDresser Wayne Journalprinter ReceiptprinterGilbarco GasboyDevice Console Device Address Exit PC G-SITEDevice Printer Device Address ANY Modetap Exit Source TypeLocal VSS Micros IDN Network Micros ISN Network Exit NCRNorand Title Display on Console ID ANY Working Mode ExitWorking Mode TAP Exit Nucleus PrinterTAP Emulate Sharp 750 ER-01PUTAP Emulate TAP US Emulate US SicomDevice Address ANY Address on Exit TkmaxUniwell Terminal ExitText Grayscale Screen SetupBackground Grayscale Clock Sub-Menu Title TitlerTitler OFF Exit Language English ExitChoices NONE, 6, 12, 20, 30, 60, 120, 180 Text DisplayDisplay Character / Line Left Justification DisplayInterface Type Register Settings Network Settings ExitCommunication RS-232Choices 7 or Choices ASCII, VSI-ADD, VNet, Dallmeier, MvdrChoices NONE, ODD, Even Choices ON, OFFType Type OFF Address Protocol Regcom 9.6K Baud Rate9600 Choices GENERIC, MASTER, SLAVE, OFFException Reports Exception Report OverviewON-SCREEN Flags Hard Alarm OutputPrinter or DVR Output Total Exceptions Total Exception000 View ExceptionsDMS-3001 DVR-3011,3021 MVDR3000, MVDR5000 Dest ID SCR ID ExitVSI-Pro Max DB9M DVR DB9FException no 00,000,000.00 00,000,000.00Operator None Exit Choices 1 throughHistory Buffer ON/OFF Programming NoteOperator Negative ExceptionChoices 00,000,000.00-99,999,999.99 Choices NONE, IN, OUTEqual OUT RangeLess than Greater thanScroll Matching 010 Alarm OutputsScroll Matching Timeout Exit Triggered Text Video Loss OFF ExitNormal State Alarm noChoices 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 Choices no Normally open, NC Normal closedTriggered Text Display Text OFF Output Text RTS Triggered DelayChoices 6, 12, 30, 60, 120, 180 30SSET Triggered Text Display TextChoices OFF, 1S, 5S, 10S, 20S, 30S, 1M, 5M, 10M Choices Manual, 1s, 2s, 3s, 4s, 5s, 10s, 20s, 30s, 1MPort 1 Test TEST/DEMO ModePort 1 Test Data Capture Register Demo Version ID Exit Receive RX Test2400 RX Baudrate Auto TX BaudrateRX / TX Test Capture to Port Capture to Port Capture to Memory Dump Memory ExitParity None Data BIT Handshaking OFF Baudrate Detection DOWNLOAD/UPLOAD Data Cable DOWNLOAD/UPLOAD SetupDemo Demo on Power UP OFF Exit PINDOWNLOAD/UPLOAD Setup Using VSI-Pro Max to VSI-Pro Max Download Setup Upload Setup Update Firmware Exit DOWNLOAD/UPLOAD Setup Sub-MenuSoftware Installation DOWNLOAD/UPLOAD Setup Using a PCVSI-Pro Max Remote Program Downloading Ver Click the Tab Remote and you will see the following Menu Remote MenuCommunication Cable Pin Out File MenuAbout Menu PC / Laptop DB9F VSI-Pro DB9MVSI-Pro Firmware Download Menu Download SetupVSI-Pro Max Firmware Download Utility Connect To Menu In-System Programming Display Problem Solving Guide Appendix aNo Video on Monitor No Network Communication or LED FlashingNo Data to the DVR from Master Characters JITTER, JUMP, or SkewVL Video Error LED on but Video Looks Good Problem Solving GuideVL Video Error LED not on but Video Looks BAD Appendix aHard Alarm Output Appendix BDVR DB9M DB9F Appendix CDVR Text Input Connections Screw TerminalsAGC UTP Connections Appendix DVSI-Pro Max RJ45 Pin Outs RJ45 Out Front Panel Appendix EP2RS Parallel to Serial Converter RS DB-9F VSI-Pro DB-9MUSB to RS-232 Converter Appendix FVsib for Thai, Korean or Chinese Languages Vsib InstallationAppendix G Vsib DB-9M VSI-Pro DB-9MECR / Tpif Interface Cards Ansi Driver Commands AppendixAppendix H Appendix J RS-232 to RS-485/422 Converter PCBTcpip DB-9M Tcpip 232 Adapter Appendix KTcpip 232 Adapter RXD TXD GNDNetwork Types Appendix LVSI-Pro Max Networking VSI-Pro Max Network CapabilityMaster / Hydra Appendix M DVRDVR Appendix M Master / HydraAVE RS-485 NetworkDipswitch Settings Hydra and RegcomNetwork Protocol AVE POS Networking Protocol VSI-ADD ProtocolESC Addr Text to be Displayed Master ProtocolRS-485 Vnetworker Appendix M DVRIntroduction RS-485 VnetworkerWindows Windows Tile Horizontally Windows Tile Vertically View StatusFiles Address Select Remote KeyboardAL-16 Alarm Output Adapter Appendix NPTZ Control Access Control PanelsAppendix O POS & Cctv Applications Cash Drawers, Safes and Security DoorsLimited Warranty Appendix P Limited WarrantyDoing a Master Reset Clears ALL Programming Master ResetLimited Warranty Appendix QNorth America