AVE VSI-Pro Max operation manual Appendix M Master / Hydra, Ave, Dvr, RS-485 Network

Page 73

APPENDIX M

MASTER / HYDRA

VSI-Pro Max Networking

The VSI-Pro Max as a slave allows the connection of multiple cash register terminals to a master unit for the purpose of transaction logging.

 

 

 

VSI-Pro Max

RS-232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232 or

 

 

 

 

 

 

 

AVE

 

 

 

 

 

 

 

 

 

 

 

RS-422 RXD only

ASCII Data for

 

DVR

Cash Register

 

 

 

 

 

Text Search

 

 

 

 

 

 

 

and Exceptions

 

 

 

 

 

 

RS-485 Network

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regcom

VSI-Pro Max

 

VSI-Pro Max

VSI-Pro Max

 

Regcom

 

 

 

 

 

 

 

 

 

 

 

 

VSI-Pro

RS-232

RS-232 or

RS-232 or

RS-232 or

only

RS-422 RXD only

RS-422 RXD only

RS-422 RXD only

RS-232

Cash Register

 

Cash Register

 

Cash Register

 

Cash Register

Figure 135: VSI-Pro Max Networking Connection Diagram

NETWORK TERMINATION

Cash Register

The device at end of the network must be “TERMINATED”. For the Hydra an 8 DIP Switch on the rear of the unit is used to set the termination. When the switch is set to “ON”, the device is terminated. When the switch is set to “OFF”, it will be un-terminated. For the VSI-Pro Max an internal jumper JP15 must be set to terminate.

DB-9 Pin-Out

Pin 1

Alarm 1

 

 

Pin 2

To Register

 

 

Pin 3

TXD (Master)

 

 

Pin 4

DTR

 

 

Pin 5

Ground

 

 

Pin 6

DSR

 

 

Pin 7

RTS

 

 

Pin 8

CTS

 

 

Pin 9

Alarm 2

 

 

DB-9 Pin-Out

Pin 1

Pin 2 RX ( RS-232 )

Pin 3 TX ( RS-232 )

Pin 4

Pin 5 Ground

Pin 6

Pin 7

Pin 8

Pin 9

RJ-45 Pin-Out

Pin 1

 

 

 

 

 

Pin 2

 

 

 

 

 

Pin 3

 

 

 

 

 

Pin 4

RS-485

( + )

 

 

 

Pin 5

RS-485

( - )

 

 

 

Pin 6

 

 

 

 

 

Pin 7

 

 

 

 

 

Pin 8

 

 

 

 

 

Table 7: RJ-45 Pin-Out

Table 5 : VSI-Pro Max Master Output Table 6: Hydra DB-9 Pin-Out

VSI-Pro Max POS / Cash Register Interface

73

Image 73
Contents September VSI-PRO MAXVSI-Pro Max Contents Figures Register Select Sub-Menu ContentsRecerve RX Test Sub-Menu VSI / VSI+ / VSI-Pro / VSI-Pro Max Backward Compatibility IntroductionFeatures Features & SpecificationsDTR / DSR SpecificationsConnections LED IndicatorsDTR PIN # Signal Name RS232DSR RTSTo Earth Ground for Surge Suppression PIN # Function DirectionVideo Surge / Lightning Protection Grounding and IsolationRS-232 DB9F Shielding User Front Panel Controls Down Up Set ResetFront Panel Controls Changing the Horizontal Position Getting Started ProgrammingMain Programming Menu Register SelectNext page Exit TCP/IPTCP/IP Limitations Mode Emulating Exit Model TK-T500 Mode Emulating ExitGeneric Addressable VSI VSI-ADDDresser Wayne Delta SonoPOS / CDU Nucleus Journalprinter ReceiptprinterDevice Console Device Address Exit GasboyGilbarco PC G-SITELocal VSS Micros IDN Network Micros ISN Network Exit Source TypeDevice Printer Device Address ANY Modetap Exit NCRWorking Mode TAP Exit Title Display on Console ID ANY Working Mode ExitNorand Nucleus PrinterTAP Emulate TAP US Emulate US Sharp 750 ER-01PUTAP Emulate SicomUniwell TkmaxDevice Address ANY Address on Exit Terminal ExitText Grayscale Screen SetupBackground Grayscale Clock Sub-Menu Titler OFF Exit TitlerTitle Language English ExitChoices NONE, 6, 12, 20, 30, 60, 120, 180 Text DisplayDisplay Character / Line Display Left JustificationCommunication Register Settings Network Settings ExitInterface Type RS-232Choices NONE, ODD, Even Choices ASCII, VSI-ADD, VNet, Dallmeier, MvdrChoices 7 or Choices ON, OFF9600 Type OFF Address Protocol Regcom 9.6K Baud RateType Choices GENERIC, MASTER, SLAVE, OFFException Report Overview Exception ReportsON-SCREEN Flags Hard Alarm OutputPrinter or DVR Output 000 Total ExceptionTotal Exceptions View ExceptionsDest ID SCR ID Exit DMS-3001 DVR-3011,3021 MVDR3000, MVDR5000DVR DB9F VSI-Pro Max DB9MOperator None Exit 00,000,000.00 00,000,000.00Exception no Choices 1 throughProgramming Note History Buffer ON/OFFChoices 00,000,000.00-99,999,999.99 Negative ExceptionOperator Choices NONE, IN, OUTOUT Range EqualLess than Greater thanScroll Matching Scroll Matching Timeout Exit Alarm Outputs010 Triggered Text Video Loss OFF ExitChoices 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 Alarm noNormal State Choices no Normally open, NC Normal closedChoices 6, 12, 30, 60, 120, 180 Display Text OFF Output Text RTS Triggered DelayTriggered Text 30SChoices OFF, 1S, 5S, 10S, 20S, 30S, 1M, 5M, 10M Display TextSET Triggered Text Choices Manual, 1s, 2s, 3s, 4s, 5s, 10s, 20s, 30s, 1MPort 1 Test Data Capture Register Demo Version ID Exit TEST/DEMO ModePort 1 Test Receive RX Test2400 RX Baudrate Auto TX BaudrateRX / TX Test Capture to Port Capture to Port Capture to Memory Dump Memory ExitParity None Data BIT Handshaking OFF Baudrate Detection Demo Demo on Power UP OFF Exit DOWNLOAD/UPLOAD SetupDOWNLOAD/UPLOAD Data Cable PINDOWNLOAD/UPLOAD Setup Using VSI-Pro Max to VSI-Pro Max DOWNLOAD/UPLOAD Setup Sub-Menu Download Setup Upload Setup Update Firmware ExitSoftware Installation DOWNLOAD/UPLOAD Setup Using a PCVSI-Pro Max Remote Program Downloading Ver Remote Menu Click the Tab Remote and you will see the following MenuAbout Menu File MenuCommunication Cable Pin Out PC / Laptop DB9F VSI-Pro DB9MVSI-Pro Firmware Download Menu Download SetupVSI-Pro Max Firmware Download Utility Connect To Menu In-System Programming Display Appendix a Problem Solving GuideNo Data to the DVR from Master No Network Communication or LED FlashingNo Video on Monitor Characters JITTER, JUMP, or SkewVL Video Error LED not on but Video Looks BAD Problem Solving GuideVL Video Error LED on but Video Looks Good Appendix aAppendix B Hard Alarm OutputDVR Text Input Connections Appendix CDVR DB9M DB9F Screw TerminalsAGC UTP Connections Appendix DVSI-Pro Max RJ45 Pin Outs RJ45 Out P2RS Parallel to Serial Converter Appendix EFront Panel RS DB-9F VSI-Pro DB-9MAppendix F USB to RS-232 ConverterAppendix G Vsib InstallationVsib for Thai, Korean or Chinese Languages Vsib DB-9M VSI-Pro DB-9MECR / Tpif Interface Cards Ansi Driver Commands AppendixAppendix H RS-232 to RS-485/422 Converter PCB Appendix JTcpip 232 Adapter Tcpip 232 Adapter Appendix KTcpip DB-9M RXD TXD GNDVSI-Pro Max Networking Appendix LNetwork Types VSI-Pro Max Network CapabilityDVR Master / Hydra Appendix MAVE Appendix M Master / HydraDVR RS-485 NetworkHydra and Regcom Dipswitch SettingsESC Addr Text to be Displayed AVE POS Networking Protocol VSI-ADD ProtocolNetwork Protocol Master ProtocolDVR RS-485 Vnetworker Appendix MRS-485 Vnetworker IntroductionWindows Windows Tile Horizontally Windows Tile Vertically View StatusFiles Remote Keyboard Address SelectAppendix N AL-16 Alarm Output AdapterAppendix O POS & Cctv Applications Access Control PanelsPTZ Control Cash Drawers, Safes and Security DoorsLimited Warranty Limited Warranty Appendix PLimited Warranty Master ResetDoing a Master Reset Clears ALL Programming Appendix QNorth America