AVE VSI-Pro Max operation manual Left Justification, Display

Page 29

PROGRAMMING

DISPLAY FORMAT

If “TOP” is selected which is the default, the data scrolls from the top most line down to the selected number of lines displayed. “T/D” and/or “TITLE” is displayed at the top of the screen. If “BOTTOM” is selected then the data scrolls up from the bottom most line to the top of the screen and “T/D” and/or “TITLE” is displayed at the bottom of the screen.

LINE COMPRESS

NOTE ? Set your Exceptions first before enabling this feature.

The VSI-Pro automatically compresses the spaces in a line first as it reaches 40 characters. With LINE COMPRESS “ON”, the VSI-Pro will additionally remove multiple spaces and then vowels from the text to further compress the display as necessary.

To make this selection, position the arrow in front of “LINE COMPRESS” and press and release “Set”. The arrow will start flashing. Cycle through “ON” or “OFF” by pressing either the “Up” or “Down” button, and press “Set” when your choice is displayed. The cursor will stop flashing and you can continue programming.

SPACE COMPRESS

Space Compress allows you select the number of maximum spaces next to each other in a line. The selections are 1,2,3,4,5 and OFF. If you select “1” then if three spaces are shown on the receipt the VSI-Pro will delete 2 and only show 1 space between characters on the video and on the output data to the DVR.

LEFT JUSTIFICATION

When LEFT JUSTIFIED is “ON”, the VSI-Pro will start each line of text with no leading spaces from the left margin of the text display block.

SCROLL DELAY

Scroll delay ensures that lines of text remain on-screen a minimum of 0.5 seconds. This is especially useful with registers that run at a high baud rate, time-lapse VCRs in extended record modes, switchers, or multiplexers. Sometimes, the register can produce characters so quickly that they can scroll up too fast on the screen to be recorded. When SCROLL DELAY is “ON”, the VSI-Pro slows down this data feed just enough to insure that each line of text is recorded.

The choices for SCROLL DELAY are either “ON” or “OFF”. To make this selection, position the arrow in front of “SCROLL DELAY” and press and release “Set”. The arrow will start flashing. Cycle through “ON” or “OFF” by pressing either the “Up” or “Down” button, then press “Set” when your choice is displayed. The cursor will stop flashing and you can continue programming.

DISPLAY

You have the choice to globally turn “ON” or “OFF” the complete VSI-Pro text insertion function. This means no data will be visible on the monitor if you select DISPLAY “OFF”. However, if you select the DISPLAY “OFF”, you can still command each exception independently to either display on-screen or not through its program setup menu under “EXCEPTION REPORTS”. You may also choose to enable an alarm output to occur during an exception while not displaying the exception data through the program set-up in the ALARM OUTPUTS menu. With the display “OFF”, the VSI-Pro will still perform all functions as programmed, for example, exception reporting will still function, but the information will not appear on-screen unless programmed to do so in the EXCEPTIONS REPORT menu. Also the data will not show in the history buffer if not displayed.

EXIT

Press the “Up” or “Down” button to move the cursor to “EXIT” and press “Set” to return to the previous menu.

VSI-Pro Max POS / Cash Register Interface

29

Image 29
Contents September VSI-PRO MAXVSI-Pro Max Contents Figures Register Select Sub-Menu ContentsRecerve RX Test Sub-Menu VSI / VSI+ / VSI-Pro / VSI-Pro Max Backward Compatibility IntroductionFeatures Features & SpecificationsDTR / DSR SpecificationsConnections LED IndicatorsDTR PIN # Signal Name RS232DSR RTSTo Earth Ground for Surge Suppression PIN # Function DirectionRS-232 DB9F Shielding Grounding and IsolationVideo Surge / Lightning Protection Front Panel Controls Down Up Set ResetUser Front Panel Controls Changing the Horizontal Position Getting Started ProgrammingMain Programming Menu Register SelectTCP/IP Limitations TCP/IPNext page Exit Mode Emulating Exit Model TK-T500 Mode Emulating ExitGeneric Addressable VSI VSI-ADDDresser Wayne Delta SonoPOS / CDU Nucleus Journalprinter ReceiptprinterDevice Console Device Address Exit GasboyGilbarco PC G-SITELocal VSS Micros IDN Network Micros ISN Network Exit Source TypeDevice Printer Device Address ANY Modetap Exit NCRWorking Mode TAP Exit Title Display on Console ID ANY Working Mode ExitNorand Nucleus PrinterTAP Emulate TAP US Emulate US Sharp 750 ER-01PUTAP Emulate SicomUniwell TkmaxDevice Address ANY Address on Exit Terminal ExitBackground Grayscale Screen SetupText Grayscale Clock Sub-Menu Titler OFF Exit TitlerTitle Language English ExitDisplay Character / Line Text DisplayChoices NONE, 6, 12, 20, 30, 60, 120, 180 Display Left JustificationCommunication Register Settings Network Settings ExitInterface Type RS-232Choices NONE, ODD, Even Choices ASCII, VSI-ADD, VNet, Dallmeier, MvdrChoices 7 or Choices ON, OFF9600 Type OFF Address Protocol Regcom 9.6K Baud RateType Choices GENERIC, MASTER, SLAVE, OFFException Report Overview Exception ReportsPrinter or DVR Output Hard Alarm OutputON-SCREEN Flags 000 Total ExceptionTotal Exceptions View ExceptionsDest ID SCR ID Exit DMS-3001 DVR-3011,3021 MVDR3000, MVDR5000DVR DB9F VSI-Pro Max DB9MOperator None Exit 00,000,000.00 00,000,000.00Exception no Choices 1 throughProgramming Note History Buffer ON/OFFChoices 00,000,000.00-99,999,999.99 Negative ExceptionOperator Choices NONE, IN, OUTOUT Range EqualScroll Matching Greater thanLess than Scroll Matching Timeout Exit Alarm Outputs010 Triggered Text Video Loss OFF ExitChoices 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 Alarm noNormal State Choices no Normally open, NC Normal closedChoices 6, 12, 30, 60, 120, 180 Display Text OFF Output Text RTS Triggered DelayTriggered Text 30SChoices OFF, 1S, 5S, 10S, 20S, 30S, 1M, 5M, 10M Display TextSET Triggered Text Choices Manual, 1s, 2s, 3s, 4s, 5s, 10s, 20s, 30s, 1MPort 1 Test Data Capture Register Demo Version ID Exit TEST/DEMO ModePort 1 Test Receive RX TestRX / TX Test RX Baudrate Auto TX Baudrate2400 Parity None Data BIT Handshaking OFF Baudrate Detection Capture to Port Capture to Memory Dump Memory ExitCapture to Port Demo Demo on Power UP OFF Exit DOWNLOAD/UPLOAD SetupDOWNLOAD/UPLOAD Data Cable PINDOWNLOAD/UPLOAD Setup Using VSI-Pro Max to VSI-Pro Max DOWNLOAD/UPLOAD Setup Sub-Menu Download Setup Upload Setup Update Firmware ExitVSI-Pro Max Remote Program Downloading Ver DOWNLOAD/UPLOAD Setup Using a PCSoftware Installation Remote Menu Click the Tab Remote and you will see the following MenuAbout Menu File MenuCommunication Cable Pin Out PC / Laptop DB9F VSI-Pro DB9MVSI-Pro Max Firmware Download Utility Download SetupVSI-Pro Firmware Download Menu Connect To Menu In-System Programming Display Appendix a Problem Solving GuideNo Data to the DVR from Master No Network Communication or LED FlashingNo Video on Monitor Characters JITTER, JUMP, or SkewVL Video Error LED not on but Video Looks BAD Problem Solving GuideVL Video Error LED on but Video Looks Good Appendix aAppendix B Hard Alarm OutputDVR Text Input Connections Appendix CDVR DB9M DB9F Screw TerminalsVSI-Pro Max RJ45 Pin Outs RJ45 Out UTP Connections Appendix DAGC P2RS Parallel to Serial Converter Appendix EFront Panel RS DB-9F VSI-Pro DB-9MAppendix F USB to RS-232 ConverterAppendix G Vsib InstallationVsib for Thai, Korean or Chinese Languages Vsib DB-9M VSI-Pro DB-9MAppendix H Ansi Driver Commands AppendixECR / Tpif Interface Cards RS-232 to RS-485/422 Converter PCB Appendix JTcpip 232 Adapter Tcpip 232 Adapter Appendix KTcpip DB-9M RXD TXD GNDVSI-Pro Max Networking Appendix LNetwork Types VSI-Pro Max Network CapabilityDVR Master / Hydra Appendix MAVE Appendix M Master / HydraDVR RS-485 NetworkHydra and Regcom Dipswitch SettingsESC Addr Text to be Displayed AVE POS Networking Protocol VSI-ADD ProtocolNetwork Protocol Master ProtocolDVR RS-485 Vnetworker Appendix MRS-485 Vnetworker IntroductionFiles View StatusWindows Windows Tile Horizontally Windows Tile Vertically Remote Keyboard Address SelectAppendix N AL-16 Alarm Output AdapterAppendix O POS & Cctv Applications Access Control PanelsPTZ Control Cash Drawers, Safes and Security DoorsLimited Warranty Limited Warranty Appendix PLimited Warranty Master ResetDoing a Master Reset Clears ALL Programming Appendix QNorth America