AVE VSI-Pro Max Communication, Register Settings Network Settings Exit, Interface Type, RS-232

Page 30

PROGRAMMING

5.6 COMMUNICATION

This was discussed briefly in the section under “REGISTER SELECT” and will be fully explained here. When you choose your register type under the REGISTER SELECT menu, this automatically formats the VSI-Pro to the appro- priate settings needed to communicate with your register. There may be times when you will need to amend these settings for a specific register.

To access the Communication menu, press the “Up” or “Down” button to move the cursor to “COMMUNICATION” and press “Set”. The following menu will appear:

REGISTER SETTINGS

NETWORK SETTINGS

EXIT

Figure 62: COMMUNICATION Sub-Menu

The “Register Settings” selects and allows you to program the communication and protocol parameters used to communicate with the POS or Cash Register using the DB9 connector. The “Network Settings” selects and allows you to program the communication and protocol parameters used to network the VSI-Pro Max to other units using the RJ45 connector.

To access the Communication menu, press the “Up” or “Down” button to move the cursor to “COMMUNICATION” and press “Set”. The following menu will appear:

INTERFACE TYPE

RS-232

RX BAUD RATE

AUTO

TX BAUD RATE

AUTO

TX PROTOCOL

ASCII

PARITY

NONE

DATA BITS

8

HW HANDSHAKING

OFF

SW HANDSHAKING

NONE

AUTO LINEFEED

ON

EXIT

 

Figure 63: Register Settings Sub-Menu

INTERFACE TYPE

Choices: RS-232, PASSIVE TAP, RS-485

To set the interface type for your particular device, press the “Up” or “Down” button to move the cursor to “INTERFACE TYPE” and press and release “Set”. The cursor will start flashing. You can now use the “Up” or “Down” button to make your selection. When your selection appears, press “Set” again. The cursor will stop flashing and you can proceed to the next menu item for programming. RS-232 and RS-485 are defined by IEEE standards, however, the Passive Tap is a high impedance (100K) input with full diode protection. Refer to Table 1 and 1A for respective pin-outs of RS-232 or RS-485.

RX BAUD RATE

Choices: AUTO, 1200, 2400, 4800, 9600, 14.4K, 19.2K, 28.8K, 38.4K, 57.6K, 115.2K

To set the baud rate for your particular device, press the “Up” or “Down” button to move the cursor to “RX Baud Rate” and press “Set”. The cursor will start flashing. You can now use the “Up” or “Down” button to make your selection. When your selection appears, press “Set” again. The cursor will stop flashing and you can proceed to the next menu item for programming.

VSI-Pro Max POS / Cash Register Interface

30

Image 30
Contents VSI-PRO MAX SeptemberVSI-Pro Max Contents Figures Contents Register Select Sub-MenuRecerve RX Test Sub-Menu Introduction VSI / VSI+ / VSI-Pro / VSI-Pro Max Backward CompatibilityFeatures & Specifications FeaturesSpecifications DTR / DSRLED Indicators ConnectionsDSR PIN # Signal Name RS232DTR RTSPIN # Function Direction To Earth Ground for Surge SuppressionGrounding and Isolation Video Surge / Lightning ProtectionRS-232 DB9F Shielding Down Up Set Reset User Front Panel ControlsFront Panel Controls Changing the Horizontal Position Main Programming Menu ProgrammingGetting Started Register SelectTCP/IP Next page ExitTCP/IP Limitations Generic Model TK-T500 Mode Emulating ExitMode Emulating Exit Addressable VSI VSI-ADDPOS / CDU Nucleus Delta SonoDresser Wayne Journalprinter ReceiptprinterGilbarco GasboyDevice Console Device Address Exit PC G-SITEDevice Printer Device Address ANY Modetap Exit Source TypeLocal VSS Micros IDN Network Micros ISN Network Exit NCRNorand Title Display on Console ID ANY Working Mode ExitWorking Mode TAP Exit Nucleus PrinterTAP Emulate Sharp 750 ER-01PUTAP Emulate TAP US Emulate US SicomDevice Address ANY Address on Exit TkmaxUniwell Terminal ExitScreen Setup Text GrayscaleBackground Grayscale Clock Sub-Menu Title Titler Titler OFF Exit Language English ExitText Display Choices NONE, 6, 12, 20, 30, 60, 120, 180Display Character / Line Left Justification DisplayInterface Type Register Settings Network Settings ExitCommunication RS-232Choices 7 or Choices ASCII, VSI-ADD, VNet, Dallmeier, MvdrChoices NONE, ODD, Even Choices ON, OFFType Type OFF Address Protocol Regcom 9.6K Baud Rate9600 Choices GENERIC, MASTER, SLAVE, OFFException Reports Exception Report OverviewHard Alarm Output ON-SCREEN FlagsPrinter or DVR Output Total Exceptions Total Exception000 View ExceptionsDMS-3001 DVR-3011,3021 MVDR3000, MVDR5000 Dest ID SCR ID ExitVSI-Pro Max DB9M DVR DB9FException no 00,000,000.00 00,000,000.00Operator None Exit Choices 1 throughHistory Buffer ON/OFF Programming NoteOperator Negative ExceptionChoices 00,000,000.00-99,999,999.99 Choices NONE, IN, OUTEqual OUT RangeGreater than Less thanScroll Matching 010 Alarm OutputsScroll Matching Timeout Exit Triggered Text Video Loss OFF ExitNormal State Alarm noChoices 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 Choices no Normally open, NC Normal closedTriggered Text Display Text OFF Output Text RTS Triggered DelayChoices 6, 12, 30, 60, 120, 180 30SSET Triggered Text Display TextChoices OFF, 1S, 5S, 10S, 20S, 30S, 1M, 5M, 10M Choices Manual, 1s, 2s, 3s, 4s, 5s, 10s, 20s, 30s, 1MPort 1 Test TEST/DEMO ModePort 1 Test Data Capture Register Demo Version ID Exit Receive RX TestRX Baudrate Auto TX Baudrate 2400RX / TX Test Capture to Port Capture to Memory Dump Memory Exit Capture to PortParity None Data BIT Handshaking OFF Baudrate Detection DOWNLOAD/UPLOAD Data Cable DOWNLOAD/UPLOAD SetupDemo Demo on Power UP OFF Exit PINDOWNLOAD/UPLOAD Setup Using VSI-Pro Max to VSI-Pro Max Download Setup Upload Setup Update Firmware Exit DOWNLOAD/UPLOAD Setup Sub-MenuDOWNLOAD/UPLOAD Setup Using a PC Software InstallationVSI-Pro Max Remote Program Downloading Ver Click the Tab Remote and you will see the following Menu Remote MenuCommunication Cable Pin Out File MenuAbout Menu PC / Laptop DB9F VSI-Pro DB9MDownload Setup VSI-Pro Firmware Download MenuVSI-Pro Max Firmware Download Utility Connect To Menu In-System Programming Display Problem Solving Guide Appendix aNo Video on Monitor No Network Communication or LED FlashingNo Data to the DVR from Master Characters JITTER, JUMP, or SkewVL Video Error LED on but Video Looks Good Problem Solving GuideVL Video Error LED not on but Video Looks BAD Appendix aHard Alarm Output Appendix BDVR DB9M DB9F Appendix CDVR Text Input Connections Screw TerminalsUTP Connections Appendix D AGCVSI-Pro Max RJ45 Pin Outs RJ45 Out Front Panel Appendix EP2RS Parallel to Serial Converter RS DB-9F VSI-Pro DB-9MUSB to RS-232 Converter Appendix FVsib for Thai, Korean or Chinese Languages Vsib InstallationAppendix G Vsib DB-9M VSI-Pro DB-9MAnsi Driver Commands Appendix ECR / Tpif Interface CardsAppendix H Appendix J RS-232 to RS-485/422 Converter PCBTcpip DB-9M Tcpip 232 Adapter Appendix KTcpip 232 Adapter RXD TXD GNDNetwork Types Appendix LVSI-Pro Max Networking VSI-Pro Max Network CapabilityMaster / Hydra Appendix M DVRDVR Appendix M Master / HydraAVE RS-485 NetworkDipswitch Settings Hydra and RegcomNetwork Protocol AVE POS Networking Protocol VSI-ADD ProtocolESC Addr Text to be Displayed Master ProtocolRS-485 Vnetworker Appendix M DVRIntroduction RS-485 VnetworkerView Status Windows Windows Tile Horizontally Windows Tile VerticallyFiles Address Select Remote KeyboardAL-16 Alarm Output Adapter Appendix NPTZ Control Access Control PanelsAppendix O POS & Cctv Applications Cash Drawers, Safes and Security DoorsLimited Warranty Appendix P Limited WarrantyDoing a Master Reset Clears ALL Programming Master ResetLimited Warranty Appendix QNorth America