Motorola ML910TM manual ML910 R1.0 RF Pass-through Upgrade Procedure, Version A

Page 7
Manual background

available drive, usually the standard Hard Disk Drive. Please refer to the ML910™ Rugged Notebook User Guide (6871008P31), Chapter 5, for complete instructions on how to access and use the BIOS Setup Utility, to check and change the Boot Device Priority if necessary.

12.Confirm that your EC BIOS version is 4.7 or earlier. Then reboot your notebook using the bootable disc that you just created. If EC BIOS is 4.8 or later, skip steps 13 and 14.

Caution

It is critically important that the EC BIOS procedure be performed with the utmost care. Among other precautions, make sure the ML910 is securely plugged into a reliable AC power source. If this FLASH procedure should be interrupted and fail, there is no “undo” or recovery procedure. The ML910 would need to be returned to Motorola’s Service Depot for repair.

13.Choose “Y” - Yes to update the EC BIOS to version 4.8. This will take about 20 seconds to complete and the system will restart automatically.

14.After the EC BIOS update is completed, eject and remove the bootable CD and restart the system, allowing it to boot-up in the Windows mode.

15.In the Windows mode, insert the upgrade disc and locate the ML Applications upgrade package in the ML APPLICATION folder. Follow the ML910 ML Application Upgrade procedures in the next sections to upgrade the ML Applications to version 4.A.

ML910 R1.0 RF Pass-through Upgrade Procedure, Version A

7

Image 7
Contents 2 Support RF Pass-through in Retrofitted ML900 Docking Stations ML910 R1.0 RF Pass-through Upgrade Procedure, Version APurpose and Requirements What You Will NeedML910 R1.0 RF Pass-through Upgrade Procedure, Version A ML910 R1.0 RF Pass-through Upgrade Procedure, Version A Step-by-Step ProcedureTo determine the EC BIOS version Perform Procedures I, II and III in order I. EC BIOS Upgrade Procedure6. Click on “Disc Image or Saved Project” 5. Click on “Image, Project, Copy”9. Burning process and status are displayed ML910 R1.0 RF Pass-through Upgrade Procedure, Version A a. MLSERVICE folder II. ML User Application Upgrade Procedurea. Click Start Control Panel Add or Remove Programs 6. Double-click on SETUP.EXE in the MLSERVICE folder 5. Click Yes to install Microsoft Visual C++ 2005 Runtime Libraries7. Click the Next button to continue 9. Click the Next button to start the installation 8. Accept the default settings and click the Next button10. Please wait while MLService is being installed ML910 R1.0 RF Pass-through Upgrade Procedure, Version A 14. Accept the default settings and click the Next button 12. Double-click on SETUP.EXE in the MLUA folder13. Click the Next button to continue 16. Please wait while ML User Application is being installed 15. Click the Next button to start the installation17. Click on the Close button when ML User Application is successfully installed 2. Uninstall the existing version of the ML Administrator Application III. ML Administrator Application Upgrade Procedureb. Select ML Administrator Application and click Remove to uninstall 6. Accept the default settings and click the Next button 4. Double-click on setup.exe 5. Click the Next button to continue8. Please wait while ML Administrator Application is being installed 7. Click the Next button to start the installation9. Click on the Close button when ML Administrator Application is successfully installed IV. Enabling the RF Pass-Through Option Using MLAA and MLUA 5. Launch the ML User Application 11. Note that the RF Pass-Through Option will not be applicable under the following conditions