Upgrading Firmware
2.Click the Communications Settings button to open the Communications Settings dialog (FIG. 82).
FIG. 82 Communications Settings dialog box
3.Click on the NetLinx Master radio button from the Platform Selection section.
4.Click on the Virtual Master radio box from the Transport Connection Option section to configure the PC to communicate directly with a panel. Everything else, such as the Authentication, is greyed- out because this connection is not going through the Master’s UI.
5.Click the Edit Settings button on the Communications Settings dialog to open the Virtual NetLinx Master Settings dialog.
6.From within this dialog, enter the System number. The default is 1.
7.Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx Studio application.
8.Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The default System value is one.
9.
The panel will not appear as a device below the virtual system number (in the Online Tree tab) until both the system number used in step 7 for the VNM is entered into the Master Connection section of the System Settings page and the panel is restarted.
Step 3: Confirm and Upgrade the firmware via the USB port
Use the
A
1.Verify that the direct USB connection
2.With the panel already configured for USB communication and the Virtual Master setup within NetLinx Studio, verify that the panel is ready to receive files.
95 | |
|
|