Configuring Communication

Master Connection to a Virtual Master via Ethernet

When configuring the panel to communicate with a Virtual Master on your PC via wireless Ethernet, the Master IP/URL field must be configured to match the IP Address of the PC. Make sure to use the Virtual System value assigned to the Virtual Master within NetLinx Studio.

Before beginning:

1.Verify that the panel has been configured to communicate with the Wireless Access Point and confirm that the signal strength quality bargraph is On.

2.In NetLinx Studio, select Settings > Master Communication Settings from the Main menu to open the Master Communication Settings dialog (FIG. 40).

FIG. 40 Master Communications Settings dialog box

3.Click the Communications Settings button to open the Communications Settings dialog (FIG. 41).

FIG. 41 Communications Settings dialog box

4.Click on the Virtual NetLinx Master radio button (from the Platform Selection section) to indicate that you are working as a NetLinx Master.

38

MVP-5200i Modero Viewpoint Widescreen Touch Panel

Page 46
Image 46
AMX MVP-5200i manual Master Connection to a Virtual Master via Ethernet, Master Communications Settings dialog box