Programming

"^" Button Commands (Cont.)

^JST

The alignment of 0 is followed by ',<left>,<top>'. The left and top coordinates are relative

Set text

to the upper left corner of the button.

Syntax:

alignment using a

numeric keypad

"'^JST-<vt addr range>,<button states range>,<new text

layout for those

alignment>'"

buttons with a

Variable:

defined address

 

range.

variable text address range = 1 - 4000.

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

1 = Off state and 2 = On state).

 

new text alignment = Value of 1 - 9 corresponds to the following locations:

 

Example:

 

SEND_COMMAND Panel,"'^JST-500.504&510.515,1&2,1'"

 

Sets the text alignment to the upper left corner for those buttons with variable text ranges

 

of 500-504 & 510-515.

 

 

^MBT

Syntax:

Set the Mouse

"'^MBT-<pass data>'"

Button mode On

Variable:

for the virtual PC.

pass data:

 

 

0 = None

 

1 = Left

 

2 = Right

 

3 = Middle

 

Example:

 

SEND COMMAND Panel,"'^MBT-1'"

 

Sets the mouse button mode to ’Left Mouse Click’.

 

 

^MDC

Syntax:

Turn On the

"'^MDC'"

’Mouse

Example:

double-click’

SEND COMMAND Panel,"'^MDC'"

feature for the

virtual PC.

Sets the mouse double-click for use with the virtual PC.

 

 

^SHO

Syntax:

Show or hide a

"'^SHO-<vt addr range>,<command value>'"

button with a set

Variable:

variable text

variable text address range = 1 - 4000.

range.

command value = (0= hide, 1= show).

 

 

Example:

 

SEND_COMMAND Panel,"'^SHO-500.504&510.515,0'"

 

Hides buttons with variable text address range 500-504 & 510-515.

 

 

130

MVP-5200i Modero Viewpoint Widescreen Touch Panel

Page 138
Image 138
AMX MVP-5200i manual Jst, Mbt, Pass data, Mdc, Sho