Multitech MT5600BL, MT5600BA Assigning Callback Passwords, Front Panel Method, AT Command Method

Page 36
Front Panel Method

Chapter 6 - Callback Security

Front Panel Method

1.Turn on the modem.

2.Starting at the STATUS screen, press the following buttons on the front panel to turn callback security on and off:

To turn on callback security, press È, È, Æ, È, È, Æ, Æ to display the CALLBACK ON? option, and then press the Enter button to select the option. When remote callback security is turned on, each caller is asked to enter a password, then is disconnected and called back by the modem. Also, dialing number locations 0–3, for use with the DS=y dialing command, are replaced by callback dialing number locations 1–30.

To turn off callback security, press È, È, Æ, È, È, Æ, Æ, Æ to display the CALLBACK OFF? option, and then press the Enter button to select the option. Callers no longer need a password to connect to the modem, the modem is unable to call them back, and stored dialing number locations 0–3 become available.

Assigning Callback Passwords

AT Command Method

1.Open a terminal program, such as HyperTerminal.

2.To store a callback password for the first callback memory location, type AT#CBP01=xxxxxxxxxx, where xxxxxxxxxx is the first password, and press ENTER. The password must be six to ten characters in length.

3.To store a callback password for the second callback memory location, type AT#CBP02=xxxxxxxxxx, where xxxxxxxxxx is the second password, and press ENTER. Note that the memory location number in the command is incremented by one.

4.Repeat as many times as necessary, up to memory location 30, until all pass- words have been entered.

Front Panel Method

1.Turn on the modem.

2.Starting at the STATUS screen, press the following buttons on the front panel: È, È, Æ, È, È, Æ, È, Æ. The ENTER PASSWORD #1? screen appears.

3.Press the Enter button on the front panel to select callback memory location 1. The ENTER PASSWORD screen appears.

4.Press the ÇÅ or È button several times to select the first letter in the password.

5.Press the Æ button to go to the next letter in the password.

Note: To backspace or to cancel an entry, press Æ several times.

6.The password must be six to ten characters in length. Repeat steps 4 and 5 until the password is entered, and then press the Enter button to store it. The PASS- WORD STORED screen should appear.

Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

36

Image 36
Contents MT5600BA/BL Series Data/Fax Modem User GuideMT5600BA-V.92 MT5600BA-V.90 MT5600BL-V.90 MultiModemII User Guide Record of RevisionsTrademarks PatentsTable of Contents Table of ContentsMultiModemII User Guide None of the Indicators Light Chapter 1 - Description and Features About AT CommandsFeatures Product DescriptionSafety Warnings Connect theTwo-Wire Leased Line Step 1 - Connect the Modem to Your SystemConnect the Modem to Your PC Connect the Modem to the Telephone Line Dialup ConnectionConnect the Four-Wire Leased Line Connect the Modem to the AC Power OutletPower-On Test Connect the Phone to the Modem OptionalStep 2 - Install the Modem Driver Installing the Modem Driver for Windows 98/Me/2000 XPInstalling the Modem Driver for Windows NT Removing an Old Modem DriverStep 3 - Setting Your Country or Region Code Using the LCD PanelUsing the Global Wizard MT5600BA-V.92 OnlyStep 4 - Install PhoneTools Using AT CommandsHow to Change the Country/Region Code How to Verify the CodeChapter 3 - Using the Front Panel Modem ConfigurationLED Indicators Liquid Crystal Display LCD Option SelectionMenu Structure Menu Overview TrunksLimbs BranchesStatus Trunk Limbs TwigsBasic Options Trunk LimbsBranches TwigsBasic Options Trunk, continued Continued from previous pageAdvanced Options Trunk Advanced Options Trunk, continued Remote Configuration Options Trunk Diagnostic Options TrunkLimb Phone Number Memory Options Trunk Caller ID Options TrunkMenu Options StatusBasic Options ASYNC, NORM? Normal asynchronous transmission using the Advanced Options VIEW S-REGISTER SETTINGS. Use the Æ, È, ÇÅ, and Enter buttons to select the number of the S-register whose value you want displayed. To scroll through a list of digits, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To display the value, press the Enter button. Same as the Sr? command Remote Configuration Options Diagnostic OptionsPhone Number Memory Options Caller ID Options Two-Wire Setup Chapter 4 - Leased Line OperationFour-Wire Setup Dial Backup and Leased-Line Restoral Dial Backup and Leased Line Restoral Setup10. Press the Æ button to go to the next digit in the number Chapter 5 - Remote Configuration Basic ProcedureSetup Changing the Remote Configuration PasswordChanging the Remote Escape Character Setup Procedures AT Command MethodChapter 6 - Callback Security Turning Callback Security On and OffAssigning Callback Passwords AT Command MethodFront Panel Method Assigning Callback Phone Numbers Front Panel MethodCalling Procedure Callback Security Commands Command #DBn Callback Enable/DisableCommand #CBN y= - x Store Callback Number Command #CBP y= x Store Callback PasswordLocationPasswordPhone Number Callback Assignments FormChapter 7 - Troubleshooting None of the Indicators LightThe Modem Does Not Respond to Commands The Modem Cannot Connect When Dialing The Modem Disconnects While Online The Modem Cannot Connect When Answering File Transfer Is Slower Than It Should BeData Is Being Lost There Are Garbage Characters on the Monitor The Modem Doesn’t Work with Caller IDFax and Data Software Can’t Run at the Same Time Appendix A - Regulatory Compliance FCC Part 68 TelecomFax Branding Statement Canadian Limitations NoticeEMC, Safety, and R&TTE Directive Compliance International Modem RestrictionsNew Zealand Telecom Warning Notice South African Notice Appendix B - Technical Specifications loop Upgrade Overview Appendix D - Upgrading the FirmwareIntroduction Step 1 - Identify the Modem FirmwareStep 3 - Download the Upgrade File Step 4 - Extract the Upgrade FilesStep 2 - Identify the Current Firmware Version Step 6 - Upgrade the Modem’s Firmware Step 7 - Restore Your ParametersStep 5 - Clear Your Stored Paramenters Appendix E - Installing a Modem Under Linux Using the Terminal Program Minicom to Verify OperationStandard Linux Serial Port Definitions InstallationUsing the Modem to Call the Internet Calling the ISPAnswering Calls 3. Select Dialup Configuration ToolAppendix F - Pin Descriptions RS-232 Pin DescriptionsRS-232 Cable Pinouts Appendix F - Pin DescriptionsLeased Line Pinouts DTE Mini-DIN 8-pin connectorDCE DB-25 connector HSKi CTS HSKo RTSIndex