APPENDIX D - Approvals

LVD - Safety Statements:

Power Rating Information - AC Source:

1.

Voltage Range:

230/120Vac.

2.

Current Range

40mA at 230V and 85mA at 120V.

3.

Frequency Range

50/60Hz.

Safety Instructions:

1.The apparatus must be installed and maintained by COMPETENT SERVICE PERSONNEL.

2.Disconnect power and line connector on the modem before attempting to change the PIM module.

3.The apparatus is a class 1 device and must be connected to a suitable earth.

Disconnect device statement:

The mains plug on the equipment serves as the disconnect device, therefore a socket outlet shall be installed near the equipment and shall be easily accessible.

TTE - Network and Safety statements

The AC power connection has a saftey status of HAZARDOUS VOLTAGE.

The line Network connection has a safety status of TNV-1

The X.21 Network Interface Port has a safety status of Un-earthed SELV.

The X.21bis Network Interface Port has a safety status of Un-earthed SELV.

The V.35 Network Interface Port has a safety status of Un-Earthed SELV.

The V36 Network Interface Port has a safety status of Earthed SELV.

The RS530 Network Interface Port has a safety status of Earthed SELV.

The G.703 Digital Network Interface Port has a safety status of Earthed SELV.

Caution - Electrostatic Sensitive Device

Electrostatic precautions should be used at all times when handling the Plug in Modules.To ensure continued compliance, ensure any port or connector when not in use is protected by the cover or dummy plug supplied.

EMC - Statements:

This is a class B product (with exception to its use with the V.35 Interface which renders the unit as a Class A product). In a domestic environment this product may cause radio interefence in which case the user may be required to take adequate measures.

EMC Test conditions:

During EMC testing, the digital port cable used was of a screened type. To ensure compliance, it is recommended that a screened cable is used on this port when in use.

Manufacturers Declaration* ATL Telecom Ltd declares that this product is in conformity with the essential requirements of the 'R&TTE directives 1999/5/EC'

* A copy of the Declaration of Conformity is available upon request from ATL Telecom Ltd.

A-10

Image 49
Contents Base Band Modem ATL Part No /203/002/610 Issue 4 SeptemberInformation Contained This Document is Confidential to Contents Appendix B International Models IntroductionBaseband Modems Constructional DetailsInterface Modules System Overview System Overview Testing InstallationBBM to BBM Link Self Test PassLink Mode LTU Ready No Alarm LTU Not ReadyBBM to Line Card Link Network ModeMenu Operation Front Panel FeaturesLoop back On Loop back OffOver all Status Status MenuLoop Active No Alarm No Signal Receiving AIS No Alignment Alarm StatusLOS/CD Fail CD FailLine Rate User RateInterface Status Link Mode Network Mode Operating ModeLocal loop Test MenuLocal loop from menu Top level display shows Loc Loop Off Loc Loop OnLocal loop from DTE LoopbackLoopback is applied by selecting the display Loopback Off Loopback OnRemote Loop from menu Remote LoopRem Loop Off Rem Loop OnRemote loop from DTE Binary PatternsBin Keys Off Sending Bin Data Test Error Count Bit Error Rate BER = User Data Rate x TimeOverview OperationErrors s000001 Errors nnnnnnErrors Data TestTransparent Mode Injection ModeInjecting 0s Injecting 1sSvc Test Service TestComms Evp Rx Evp Tx Time If the count is stopped the display is StopSelf Test Lamp TestComm Loop Off Communication Channel LoopbackRate 4.8K Rate MenuMaster 64K BT Slave 4.8K 2 X.21bis Option MenuSignalling Rate Asynchronous Mode3 G.703 Char Len Character LengthMaster Slave Configuration MenuLine Rate Modem 3 X.21 Loop ControlSynchronisation Type for software versions below Ext Byte Clk Synchronisation Type for software version V1.3 and aboveExt Bit Clk Internal ClkPower Level 5 64k ModeMenu Lock Glossary of Terms Band circuits General Specifications Way D-type X.21 V.11 Connector pin allocation Way D type X.21 bis V.24 / V.28* Connector pin allocationAppendix a Interface Pin Connections Way D-type V.36 Connector pin allocation Mrac Connector Pin allocationLine Connector Way D-type RS-530 Connector pin allocationAppendix B Internal Link Settings Page Interface Module Interface Modules21bis Interface Module RS530 Interface ModuleFrame Structure Service Test FacilitiesAppendix C In Service Test TTE Network and Safety statements LVD Safety Statements21 bit timing cable 15 way to 15 way D type plugs Appendix E24 / V.28 bit timing cable 25 way to 25 way D type plugs 21 byte timing cable 15 way to 15 way D type plugs35 bit timing cable 34 way to 34 way Mrac plugs RS530 bit timing cable 25 way to 25 way D type plugs 21 bis V.36 bit timing cable 37 way to 37 way D type plugsAppendix F Troubleshooting Power 10dBm Slave Mode 64K RateMaster Mode C 64K Rate Rate 64K