American Telecom AM64/128A Synchronisation Type for software version V1.3 and above, Ext Byte Clk

Page 35

AM64/128A User Manual

Configuration Menu

 

 

5.7.4.1 Synchronisation Type (for software version V1.3 and above)

With these later versions of software, there are three possible options depending upon which interface is fitted, whether Master or Slave mode is selected, and the rate selected.

Option 1 -

C > Ext Byte Clk

This option is shown when the ‘External Byte timing ON’ is selected. The Master unit accepts Byte timing from external timing input (S EXT) and uses this to synchronise the link with its remote Slave unit.

or

Option 2 -

C > Ext Bit Clk

This option is shown when the ‘External bit timing ON’ is selected. The Master unit accepts bit timing from external timing input (SEXT) and uses this to synchronise the link with its remote Slave unit.

or

Option 3 -

C > Internal Clk

This option is shown when the ‘External bit timing OFF’ is selected. The Master unit is the source of synchronous timing to its remote Slave unit and attached DTE’s at both ends of the link.

The following options are shown, when the configurations below are selected :

1.X.21 Interface, Master mode, at ALL rates except 64kbps + Byte timing (64k BT).

 

Option

2 -

or

Option

3 -

C > Ext Bit Clk

C > Internal Clk

2.X.21 Interface, Master mode, at 64kbps + Byte timing (64k + BT).

Option 1 -

C > Ext Byte Clk

or

Option

2 -

or

Option

3 -

C > Ext Bit Clk

C > Internal Clk

3.X.21 bis, V.35, V36 and RS530 Interface, Master mode, ALL rates.

Option 2 -

C > Ext Bit Clk

or

Option 3 -

C > Internal Clk

Note : If the Slave mode is selected, the options will remain as per the pre-V1.3 software as described in section 5.7.4.

35

Image 35
Contents Base Band Modem ATL Part No /203/002/610 Issue 4 SeptemberInformation Contained This Document is Confidential to Contents Appendix B International Models IntroductionInterface Modules Constructional DetailsBaseband Modems System Overview System Overview Self Test Pass InstallationTesting BBM to BBM LinkLink Mode LTU Ready No Alarm LTU Not ReadyBBM to Line Card Link Network ModeMenu Operation Front Panel FeaturesLoop back On Loop back OffLoop Active Status MenuOver all Status CD Fail Alarm StatusNo Alarm No Signal Receiving AIS No Alignment LOS/CD FailInterface Status User RateLine Rate Link Mode Network Mode Operating ModeLoc Loop On Test MenuLocal loop Local loop from menu Top level display shows Loc Loop OffLoopback On LoopbackLocal loop from DTE Loopback is applied by selecting the display Loopback OffRem Loop On Remote LoopRemote Loop from menu Rem Loop OffBin Keys Off Sending Bin Binary PatternsRemote loop from DTE Operation Error Count Bit Error Rate BER = User Data Rate x TimeData Test OverviewData Test Errors nnnnnnErrors s000001 ErrorsInjecting 1s Injection ModeTransparent Mode Injecting 0sTime If the count is stopped the display is Stop Service TestSvc Test Comms Evp Rx Evp TxSelf Test Lamp TestComm Loop Off Communication Channel LoopbackRate 4.8K Rate MenuMaster 64K BT Slave 4.8K 2 X.21bis Option Menu3 G.703 Asynchronous ModeSignalling Rate Char Len Character LengthLine Rate Configuration MenuMaster Slave Synchronisation Type for software versions below 3 X.21 Loop ControlModem Internal Clk Synchronisation Type for software version V1.3 and aboveExt Byte Clk Ext Bit ClkMenu Lock 5 64k ModePower Level Glossary of Terms Band circuits General Specifications Appendix a Interface Pin Connections Way D type X.21 bis V.24 / V.28* Connector pin allocationWay D-type X.21 V.11 Connector pin allocation Way D-type V.36 Connector pin allocation Mrac Connector Pin allocationLine Connector Way D-type RS-530 Connector pin allocationAppendix B Internal Link Settings Page Interface Module Interface Modules21bis Interface Module RS530 Interface ModuleFrame Structure Service Test FacilitiesAppendix C In Service Test TTE Network and Safety statements LVD Safety Statements21 bit timing cable 15 way to 15 way D type plugs Appendix E35 bit timing cable 34 way to 34 way Mrac plugs 21 byte timing cable 15 way to 15 way D type plugs24 / V.28 bit timing cable 25 way to 25 way D type plugs RS530 bit timing cable 25 way to 25 way D type plugs 21 bis V.36 bit timing cable 37 way to 37 way D type plugsAppendix F Troubleshooting Rate 64K Slave Mode 64K RatePower 10dBm Master Mode C 64K Rate