Cisco Systems ONS 15200 manual Configuration of the ONS 15252 Multichannel Unit

Page 32

Chapter 3 Product Hardware

Physical Layout

Figure 3-4 Configuration of the ONS 15252 Multichannel Unit

NCB - Network Controller Board

CLIP - Client Line Interface Port

NAM - Network Adaptation Module

CIM - Communications Interface Module

LM - Line Module

HFM - Hub Filter Module

DFM - Dummy Filter Module

BM - Bridge Module

A - Side

B - Side

54637

 

The lower portion of the ONS 15252 MCU is referred to as the passive optical shelf. The passive optical shelf has an A side and B side. The A side of the ONS 15252 MCU is located on the left side of the passive optical shelf, as seen from the front. The A-side LM contains one line IN port (FC), one line OUT port (FC), and two line-monitoring ports (SC). The line-monitoring ports make it possible to monitor the A-side incoming and outgoing DWDM optical signals.

The B side of the ONS 15252 MCU is located on the right side of the passive optical shelf, as seen from the front. The B-side LM contains one line IN port (FC), one line OUT port (FC), and two line-monitoring ports (SC). The line-monitoring ports make it possible to monitor the B-side incoming and outgoing DWDM optical signals. The passive optical shelf also contains the A-side and B-side HFMs and TMs, BMs, CMXs, or CMYs in various combinations. Figure 3-5shows the typical arrangement of the modules.

Cisco ONS 15200 Product Description

3-6

78-13766-01

 

 

Image 32
Contents Cisco ONS 15200 Product Description Corporate HeadquartersCisco ONS 15200 Product Description N T E N T S Alarms Acronyms A-1 Contents Cisco ONS 15200 Product Description 78-13766-01 G U R E S Viii NCB Indicators Tables Cisco ONS 15200 Product Description 78-13766-01 Manual Structure Related DocumentationWorld Wide Web Relevant StandardsObtaining Documentation Optical Networking Product Documentation CD-ROM Ordering DocumentationDocumentation Feedback Obtaining Technical AssistanceCisco.com Technical Assistance CenterCisco TAC Escalation Center Xvi Unprotected Channels Optical System DescriptionOptical Channels Protected Channels Unprotected channels in an ONS 15200 systemSoftware Configurable Protection Optically-fiber protected channels in an ONS 15200 systemPage ONS 15200 Network Configurations Bus ConfigurationRing Configuration Logical ConnectionsDual-Home Configuration Multichannel Point-to-Point ConfigurationRing Configuration with Hubbed and Meshed Traffic Full-Mesh Configuration Ring configuration with hubbed and meshed trafficFour ONS 15252 MCUs in a full-mesh configuration Network ProtectionModularity and Ancillary Equipment ONS 15252 MCUClip ONS 15201 SCU Status Cause Power Distribution PanelFan Unit Fiber Organizer ONS 15252 MCU Physical ConfigurationPhysical Layout Configuration of the ONS 15252 Multichannel Unit ONS 15201 SCU Physical Configuration Internal BUS Clip NAM Clip NCB HFMPower and Grounding Physical layout of the ONS 15201 SCUONS 15252 MCU Power and Grounding ONSElectromagnetic Compatibility Safety SpecificationsEnvironmental Compliance Channel Number Frequency THz Wavelength nm Product SafetyWavelength Grid Page Network Control Network Management OverviewCisco ONS 15200 Product Description 78-13766-01 EIA/TIA-232 RS-232 Interface Hardware PlatformsParameter Value Speed Kbps Data Bits Parity None Stop Bits Flow ControlCommand Line Interface Ethernet interfaceMaintenance Manager MA interfaceWeb-Based Interface Internal Data BusONS 15252 MCU internal data bus extension ports Cisco Transport Manager AlarmsSimple Network Management Protocol Interface Alarm Name Condition Name DefinitionAlarm Name Definition Page Overview Client Layer Interface Port ModuleEquipment Version CLIPs Restriction Temperature Communication Interface ModuleONS MaximumStatus Network Adaptation ModuleNetwork Control Board Module Bridge Module Collector Filter ModuleConnection Module Connection Module YTermination Module Hub Filter ModuleLine Module Page Operational Parameter Condition MaximumOptical Optical PerformanceOptical Frequencies Parameter Condition Minimum UnitIncludes Connectors Equipment Maximum dB Optical LossIncludes Equipment Maximum dB15201 SCU unprotected optical path 100/0 or 0/100 Environmental Parameter Condition Min Max UnitMechanical Parameter UnitsElectrical Parameter Max UnitAcronyms Control area network Electronic Industries Association International Electrotechnical Commission Internet protocol National Fire Protection Association Subnetwork Manager D E IN-2 IN-3 IN-4