Cisco Systems manual ONS 15200 Network Configurations, Bus Configuration

Page 21

C H A P T E R 2

Product Configurations

This chapter describes common Cisco ONS 15200 network configurations. All modules mentioned in this chapter are described in more detail in Chapter 5, “Module Descriptions.”

2.1 ONS 15200 Network Configurations

The ONS 15200 operates in several network configuration arrangements. All ONS 15200 configurations consist of one or more ONS 15252 Multichannel Units (MCU) or ONS 15201 Single-Channel Units (SCUs). The following information describes some standard ONS 15200 network configurations, including:

The “Bus Configuration” section on page 2-1

The “Ring Configuration” section on page 2-2

The “Dual-Home Configuration” section on page 2-3

The “Multichannel Point-to-Point Configuration” section on page 2-3

The “Ring Configuration with Hubbed and Meshed Traffic” section on page 2-4

The “Full-Mesh Configuration” section on page 2-5

2.1.1Bus Configuration

In an ONS 15200 system bus configuration, wavelength channels link an ONS 15252 MCU to ONS 15201 SCUs. Use this configuration only in networks where optical-layer fiber protection is unnecessary. It is possible to configure the bus configuration for layer-3 load-sharing protection or client layer 1+1 APS, but the two data traffic flows would need to share the same optical fiber path, and therefore protection would be incomplete.

In the bus configuration, the Client Layer Interface Port (CLIP) modules located in the ONS 15252 MCU and in each ONS 15201 SCU exchange data. Figure 2-1illustrates the ONS 15200 system bus configuration.

Note The physical connection in Figure 2-1consists of two fiber-optic cables.

Cisco ONS 15200 Product Description

 

78-13766-01

2-1

 

 

 

Image 21
Contents Corporate Headquarters Cisco ONS 15200 Product DescriptionCisco ONS 15200 Product Description N T E N T S Alarms Acronyms A-1 Contents Cisco ONS 15200 Product Description 78-13766-01 G U R E S Viii NCB Indicators Tables Cisco ONS 15200 Product Description 78-13766-01 Related Documentation Manual StructureRelevant Standards Obtaining DocumentationWorld Wide Web Ordering Documentation Optical Networking Product Documentation CD-ROMDocumentation Feedback Obtaining Technical AssistanceTechnical Assistance Center Cisco.comCisco TAC Escalation Center Xvi Optical System Description Optical ChannelsUnprotected Channels Unprotected channels in an ONS 15200 system Protected ChannelsOptically-fiber protected channels in an ONS 15200 system Software Configurable ProtectionPage Bus Configuration ONS 15200 Network ConfigurationsLogical Connections Ring ConfigurationMultichannel Point-to-Point Configuration Dual-Home ConfigurationRing Configuration with Hubbed and Meshed Traffic Ring configuration with hubbed and meshed traffic Full-Mesh ConfigurationNetwork Protection Four ONS 15252 MCUs in a full-mesh configurationONS 15252 MCU Modularity and Ancillary EquipmentClip ONS 15201 SCU Power Distribution Panel Fan UnitStatus Cause ONS 15252 MCU Physical Configuration Physical LayoutFiber Organizer Configuration of the ONS 15252 Multichannel Unit Internal BUS Clip NAM Clip NCB HFM ONS 15201 SCU Physical ConfigurationPhysical layout of the ONS 15201 SCU Power and GroundingONS ONS 15252 MCU Power and GroundingSafety Specifications Environmental ComplianceElectromagnetic Compatibility Product Safety Wavelength GridChannel Number Frequency THz Wavelength nm Page Network Management Overview Network ControlCisco ONS 15200 Product Description 78-13766-01 Hardware Platforms EIA/TIA-232 RS-232 InterfaceSpeed Kbps Data Bits Parity None Stop Bits Flow Control Parameter ValueEthernet interface Command Line InterfaceMA interface Maintenance ManagerInternal Data Bus Web-Based InterfaceONS 15252 MCU internal data bus extension ports Alarms Simple Network Management Protocol InterfaceCisco Transport Manager Condition Name Definition Alarm NameAlarm Name Definition Page Client Layer Interface Port Module OverviewCommunication Interface Module Equipment Version CLIPs Restriction TemperatureONS MaximumNetwork Adaptation Module Network Control Board ModuleStatus Collector Filter Module Bridge ModuleConnection Module Connection Module YHub Filter Module Line ModuleTermination Module Page Parameter Condition Maximum OperationalOptical Performance OpticalOptical Frequencies Parameter Condition Minimum UnitOptical Loss Includes Connectors Equipment Maximum dBEquipment Maximum dB Includes15201 SCU unprotected optical path 100/0 or 0/100 Parameter Condition Min Max Unit EnvironmentalParameter Units MechanicalParameter Max Unit ElectricalAcronyms Control area network Electronic Industries Association International Electrotechnical Commission Internet protocol National Fire Protection Association Subnetwork Manager D E IN-2 IN-3 IN-4