NCR 7882 manual Checkstand Cutout, Checkpoint Cable, Cable Clamps

Page 26

NCR RealScan 7882 Installation and Owner Guide

Checkstand Cutout

1.Put the RealScan 7882 into the hole in the checkstand. Diagrams in NCR RealScan 7882 Specifications show the various dimensions of the hole.

2.Align the RealScan 7882 to the Checkstand. The leading edge of the Top Plate must be flush or up to 1/16 in. (0.15 cm) below the top of the checkstand. The trailing edge of the Top Plate must be flush or up to 1/16 in. (0.15 cm) above the top of the checkstand.

Low Surface

High Surface

Low Surface

High Surface

 

Correct Alignment

 

Bad Alignment

Scanner Too High

Bad Alignment

 

Scanner Too Low

14231

Checkpoint Cable

If you are installing a RealScan 7882 Scanner with the Checkpoint feature on a Vertical Mounting Bracket, route the Checkpoint Cable along side the Interface Cable.

Note: If the installation includes the Checkpoint feature, a representative from Checkpoint must connect the Checkpoint Cable to the Checkpoint equipment after you install the RealScan 7882.

Cable Clamps

The RealScan 7882 is supplied with two Cable Clamps (006-0687102). Install these clamps under the checkstand as needed to support the cables and keep them out of the operator’s way.

26 of 62

09/02

497-0419630 Release F

Image 26
Contents RealScan Installation and Owner Guide Contents Revision RecordObtaining Additional Information Obtaining Technical AssistanceRealScan 7882 Mountings RealScanInstallation Instructions StepInstalling Power Supply Interface Cables Connecting the Cables to an NCR RealScanUSB Interface Connection IBM HID Auxiliary RS-232 Port Auxiliary RS-232 PortProgramming the Communication Parameters Setting Program Parameters and Verifying Host ConnectionTurning on the RealScan RS-232 NCR 2170, 7452 Ocia Short Format NCR 2113, 2126 RS-232 Ruby Verifone Ruby 4M Programming Defaults UPC/EANPrefix Byte Disable Ascii Code Programming for USB Connection RS-232 CommunicationsMaking Other Program Changes Scan Sample Tags UPC-ADetermining Label Quality 1234 5 678Setting RealScan Scan Zone Scan Zone Adjusting ScrewHorizontal Pass-by Scanning Vertical Pass-by ScanningVertical Presentation Scanning from Top Vertical Presentation Scanning from BottomPlastic Top Plate Mounting RealScanRubber Feet Connect Power Cable and Interface Cable Vertical Mounting Bracket Cable Clamps Checkstand CutoutCheckpoint Cable Operating the Scanner Cleaning the Scanner Correcting Scanner Problems Green Status Indicator Tones Problem Suspect ComponentNCR RealScan 7882 Installation and Owner Guide Most Common Interface Cables Interface ConnectorInterface Information Protocol Communications ProtocolProgramming Worksheet NCR RealScan Specifications Checkstand Hole RealScan 7882 Horizontal MountCheckstand Hole RealScan 7882 Flat Mount Electrical Wiring Ventilation RequirementsProgramming Worksheets Tone On/OffExtend UPC-E To UPC-A Version DExtend UPC-A To EAN-13 Periodical CodesCheck Digit Present CodeMinimum Characters Allowed Full Ascii Transmit Check DigitCommon Byte Minimum Data Characters Allowed UCCIdentifier Type Bar Code TypeStop Bits Character Length Baud RateParity HandshakeTerminator Byte Message DelayNormal or Eavesdrop Mode IBM Tone Control Good Read Tone ControlAscii Code Chart Regulatory Information Identification Labels CE Mark ApplicabilityDeclaration of Conformity Laser Safety Laser Safety LabelLaser Power Laser Module LabelVolume Adjustment Reset Programming TagsDefault Programming Mode End Save and Reset Abort Diagnostic Mode RS-232 Temporary Service Mode Mode Reset Tallies Hex Hex Hex Hex Hex Hex a Hex B Hex C Hex D Hex E Hex F Copyright 2001, 2002 by NCR Corporation