NCR 7882 manual Auxiliary RS-232 Port

Page 9

NCR RealScan 7882 Installation and Owner Guide

Auxiliary RS-232 Port

The Auxiliary RS-232 Port provides a connection for an RS-232 device such as a RealScan 7837 Hand-Held Scanner. The following table gives wiring information about the connector.

Auxiliary RS-232 Port

Pin Number

Signal Name

1

+5 Vdc

2

NC

3

GND

4

TXD

5

RXD

6

+ 12 Vdc

7

CTS

8

RTS

9

Frame

10

Frame

NCR RealScan 7835/7836

1416-C313-0040 – Interface Cable

1416-C397-0010 – Extension Cable

NCR RealScan 7837

1416-C445-0025 – Interface Cable

1416-C397-0010 – Extension Cable

The NCR 7882 auxiliary RS-232 port hardware is limited to the following fixed parameters.

Baud Rate

4800 (9600 before SN 40-36009427)

Parity

Odd

Stop Bits

1

Number of Data Bits

7

Hardware Handshaking

None

Terminator Character

CRLF

UPC-A Prefix Character

d

UPC-E Prefix Character

d

EAN 8 Prefix Character

d

EAN 13 Prefix Character

d

Code 128 Prefix Character

f

Code 39 Prefix Character

a

Interleaved 2 of 5 Prefix Character

b

Note: ASCII data cannot be sent from the auxiliary RS-232 port when the RealScan 7882 is set for OCIA Short format. In this case, the RealScan 7882 generates an error beep.

When a 7836 is attached to a RealScan 7882, the 7836 requires the following programming.

Reset to serial (default values) – Label ZA

Enable code ID (default values) – Label FB

497-0419630 Release F

09/02

9 of 62

Image 9
Contents RealScan Installation and Owner Guide Revision Record ContentsObtaining Technical Assistance Obtaining Additional InformationRealScan RealScan 7882 MountingsStep Installation InstructionsConnecting the Cables to an NCR RealScan Installing Power Supply Interface CablesUSB Interface Connection IBM HID Auxiliary RS-232 Port Auxiliary RS-232 PortSetting Program Parameters and Verifying Host Connection Turning on the RealScanProgramming the Communication Parameters RS-232 NCR 2170, 7452 Ocia Short Format NCR 2113, 2126 RS-232 Ruby Verifone Ruby 4M UPC/EAN Programming DefaultsPrefix Byte Disable Ascii Code RS-232 Communications Programming for USB ConnectionMaking Other Program Changes UPC-A Scan Sample Tags1234 5 678 Determining Label QualityScan Zone Adjusting Screw Setting RealScan Scan ZoneVertical Pass-by Scanning Horizontal Pass-by ScanningVertical Presentation Scanning from Bottom Vertical Presentation Scanning from TopMounting RealScan Rubber FeetPlastic Top Plate Connect Power Cable and Interface Cable Vertical Mounting Bracket Checkstand Cutout Checkpoint CableCable Clamps Operating the Scanner Cleaning the Scanner Green Status Indicator Tones Problem Suspect Component Correcting Scanner ProblemsNCR RealScan 7882 Installation and Owner Guide Interface Connector Interface InformationMost Common Interface Cables Communications Protocol Programming WorksheetProtocol Checkstand Hole RealScan 7882 Horizontal Mount NCR RealScan SpecificationsCheckstand Hole RealScan 7882 Flat Mount Ventilation Requirements Electrical WiringTone On/Off Programming WorksheetsExtend UPC-A To EAN-13 Version DExtend UPC-E To UPC-A Periodical CodesMinimum Characters Allowed Full Ascii CodeCheck Digit Present Transmit Check DigitIdentifier Type Minimum Data Characters Allowed UCCCommon Byte Bar Code TypeParity Baud RateStop Bits Character Length HandshakeNormal or Eavesdrop Mode Message DelayTerminator Byte IBM Tone Control Good Read Tone ControlAscii Code Chart Regulatory Information CE Mark Applicability Identification LabelsDeclaration of Conformity Laser Safety Label Laser SafetyLaser Module Label Laser PowerProgramming Tags Volume Adjustment ResetDefault Programming Mode End Save and Reset Abort Diagnostic Mode RS-232 Temporary Service Mode Mode Reset Tallies Hex Hex Hex Hex Hex Hex a Hex B Hex C Hex D Hex E Hex F Copyright 2001, 2002 by NCR Corporation