NCR 7882 manual Communications Protocol, Programming Worksheet

Page 32

NCR RealScan 7882 Installation and Owner Guide

Communications Protocol

The Communications Protocol function identifies the communications protocol the RealScan 7882 is using. Scan the Diagnostics Mode and Hex 3 programming tags (must be first tags scanned after applying power). Three beeps sound after scanning the Hex 3 tag, identifying the programming tag. Next, the Status Indicator flashes green and a series of beeps sound that identify the communications protocol. Use the following table to determine the communication protocol.

Tone

 

Communication Protocol

1

Beep (Short high pitched)

OCIA NCR Short / Datachecker

1

Beep

OCIA NCR Long

2

Beeps

OCIA Non-NCR

3

Beeps

IBM 468x (4A)

4

Beeps

IBM 468x (4B)

6

Beeps

RS-232

7

Beeps

OCIA Single-Cable

10

Beeps

Keyboard Wedge

11

Beeps

Casio / OCIA Non-NCR

Scan the Hex 3 tag to repeat; remove power to end.

Programming Worksheet

1 0 COMMUNICATIONS PROTOCOL

Protocol

 

0

 

1

 

3

 

4

 

 

OCIA

OCIA

 

IBM

IBM

 

NCR Short

NCR Long

Slot Scanner

Hand-Held

 

(Datachecker)

 

 

 

 

Bar Code

 

 

 

 

 

 

 

 

Reader

 

6

 

A

 

B

 

OCIA

Keyboard

IBM 1520

Single Cable

Wedge

Bar Code

 

 

 

 

 

Reader

5

RS-232

19020A

32 of 62

09/02

497-0419630 Release F

Image 32
Contents RealScan Installation and Owner Guide Contents Revision RecordObtaining Additional Information Obtaining Technical AssistanceRealScan 7882 Mountings RealScanInstallation Instructions StepInstalling Power Supply Interface Cables Connecting the Cables to an NCR RealScanUSB Interface Connection IBM HID Auxiliary RS-232 Port Auxiliary RS-232 PortProgramming the Communication Parameters Setting Program Parameters and Verifying Host ConnectionTurning on the RealScan RS-232 NCR 2170, 7452 Ocia Short Format NCR 2113, 2126 RS-232 Ruby Verifone Ruby 4M Programming Defaults UPC/EANPrefix Byte Disable Ascii Code Programming for USB Connection RS-232 CommunicationsMaking Other Program Changes Scan Sample Tags UPC-ADetermining Label Quality 1234 5 678Setting RealScan Scan Zone Scan Zone Adjusting ScrewHorizontal Pass-by Scanning Vertical Pass-by ScanningVertical Presentation Scanning from Top Vertical Presentation Scanning from BottomPlastic Top Plate Mounting RealScanRubber Feet Connect Power Cable and Interface Cable Vertical Mounting Bracket Cable Clamps Checkstand CutoutCheckpoint Cable Operating the Scanner Cleaning the Scanner Correcting Scanner Problems Green Status Indicator Tones Problem Suspect ComponentNCR RealScan 7882 Installation and Owner Guide Most Common Interface Cables Interface ConnectorInterface Information Protocol Communications ProtocolProgramming Worksheet NCR RealScan Specifications Checkstand Hole RealScan 7882 Horizontal MountCheckstand Hole RealScan 7882 Flat Mount Electrical Wiring Ventilation RequirementsProgramming Worksheets Tone On/OffVersion D Extend UPC-A To EAN-13Extend UPC-E To UPC-A Periodical CodesCode Minimum Characters Allowed Full AsciiCheck Digit Present Transmit Check DigitMinimum Data Characters Allowed UCC Identifier TypeCommon Byte Bar Code TypeBaud Rate ParityStop Bits Character Length HandshakeMessage Delay Normal or Eavesdrop ModeTerminator Byte IBM Tone Control Good Read Tone ControlAscii Code Chart Regulatory Information Identification Labels CE Mark ApplicabilityDeclaration of Conformity Laser Safety Laser Safety LabelLaser Power Laser Module LabelVolume Adjustment Reset Programming TagsDefault Programming Mode End Save and Reset Abort Diagnostic Mode RS-232 Temporary Service Mode Mode Reset Tallies Hex Hex Hex Hex Hex Hex a Hex B Hex C Hex D Hex E Hex F Copyright 2001, 2002 by NCR Corporation