P_ESI_n FUNCTION

The SEL_N (TTL compatible) inputs and outputs (defined when -Parallel ESI is asserted) provide an interface between the enclosure and the drive. Table 8 summarizes the signals.

Table 8. SEL_N/P_ESI_N Signal Definitions

-Parallel ESI (High)

-Parallel ESI (Low)

 

 

Sel_0 (Input)

P_ESI_0 (Input)

Sel_1 (Input)

P_ESI_1 (Input)

Sel_2 (Input)

P_ESI_2 (Input)

Sel_3 (Input)

P_ESI_3 (Input)

Sel_4 (Input)

P_ESI_4 (Input)

Sel_5 (Input)

P_ESI_5 (Input)

Sel_6 (Input)

-EFW (Input)

SFF-8045 ENCLOSURE SERVICE INTERFACE

The SFF-8045 Enclosure Service Interface defines 7 bits of enclosure status. This status is read by the drive, and presented to the Initiator, upon receipt of appropriate Receive Diagnostic command. The definitions of the status bits are vendor specific. The drive will not interpret the status. The drive assumes -EFW is status and treats it as if does the other P_ESI_n signals.

-ENBL_BYP CH1 AND -ENBL_BYP_CH2

These two signals are TTL outputs from the drive and provide 4mA of sink capability. The signals are intended to control the state of the loop port bypass circuit on the backplane. The drive powers up with these signals turned off. It is assumed that the backplane will provide a 1K ohm pull-down resistor that will ensure the drive is bypassed on the loop when it is not present, or when it is powering up. The drive will attempt to enable itself on both loops after a successful power up.

START_n MATED

These signals are used to control the motor spin on rotating media drives. Because the ZeusIOPS SSD is a solid-state device and has no motor, these signals are ignored by the drive.

ZeusIOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

31

Image 31
Contents ZeusIOPS Fibre Channel Inch Solid State Drive Product Manual Export Administration Regulation Manual Conventions Page Revision Status Summary Sheet Revision HistoryPage Table of Contents Electrical Specifications Performance CharacteristicsProduct Description FC-AL Features Interface SpecificationsFibre Channel Standard Physical CharacteristicsEnvironmental Characteristics InstallationContact and Ordering Information Regulatory CompliancePage List of Tables Page List of Figures Page Product ID Codes ScopeProduct ID Code Capacity Approximate Interface Specifications Standard FeaturesPerformance Characteristics Electrical SpecificationsFibre Channel Standard InstallationRegulatory Compliance Reference Documents Download upgrades via the Fibre Channel interface Environmental Characteristics Product Description Performance Characteristics Parameter Value Units Data Transfer RatesStandard DoD 522.22-M Afssi NSA Capacity Minutes Erase TimesCapacity Erase Time Sanitize Times and StandardsUnauthorized maintenance to the SSD will void the warranty Power Consumption Electrical SpecificationsPower Supply Power RequirementsReady LED OUT Signal Fault LED OUT SignalGrounding Selid to Alpa Translation Selid FunctionParallel ESI High Parallel ESI Low SELN/PESIN Signal DefinitionsSFF-8045 Enclosure Service Interface STARTn MatedLink Rate Devctrlcoden Signal DefinitionsDrive Present DevctrlcodexSSD Operation Interface SpecificationsSCA-2 Interface Connector Relative SCA-2 Connector Location Voltage and Ground Signals Pin SCA-2 Connector PinoutFC-AL Supported Options Loop ConnectionsOption Support Command Code Command Name FCP-SCSI CommandsBit Byte Operation Code A0h Reserved Select Report Report Luns CommandAllocation Length Test Unit Ready CDB Read 6 Command 08hRead 6 CDB Bit Byte Operation Code 0Ah Write 6 CDBCode Reserved Allocation Length Control Reserved Response Data Format Additional Bit Byte Peripheral Qualifier Peripheral Device TypeDevice-Type Modifier Version Ecma Version ANSI-approved VersionCode Field Descriptions Mode Sense CDBReserved Code Allocation Length Control Parameter List Length Send Diagnostics CDBParameter Pointer Log Sense CommandBit Byte Operation Code ReservedRead Capacity CDB Reserved RelAdr Read Extended 10 28hRead Extended 10 CDB Bit Byte Operation Code 28h Logical Unit number RsvdBit Byte Operation Code 2Ah Logical Unit Number Rsvd Verify 10 2FhReserve RelAdr Buffer Offset Write Buffer Command 3BhBit Byte Operation Code 3Bh Reserved Mode Buffer ID Mode Value DescriptionBit Byte Operation Code 5Ah Reserved Code Field Descriptions for Mode SenseCode Description Subclause Bit Byte Operation Code 5Fh Reserved Service Action Bit Byte Operation Code 5Eh Reserved Service ActionPersistent Reserve Command Command Code Description Unsupported Mandatory CommandsFibre Channel Arbitrated Loop Fibre Channel StandardPage Fabric Node Connection Fabric Node ConnectionClosed MonitoringArbitration OpenFCP Level Description FCP Function LevelsGeneral Physical Characteristics Physical CharacteristicsFormatted Capacities ZeusIOPS 3.5-Inch Dimensions Storage Temperatures Environmental CharacteristicsTemperature Conditions Operating TemperaturesComponent Designator Maximum Package Temperature Maximum Component TemperaturesComponent Locations System Requirements InstallationDrive Configuration Flash Series Condition Power-On Fault CodesCode Condition Description Operational Fault CodesBit Bits 5 Configuration Result Selectid ConfigurationsPossible Drive Orientations Suggested Air Flow Patterns for Cooling Underside Mounting Holes Side Mounting Holes Exterior Mounting SpecificationsDrive Installation Microsoft OS Compatibility Operating System SpecificationsWeb Browser SSD Management UtilityZeusIOPS Management Utility Requirements Operating SystemNand Flash Support Restriction of Hazardous Materials Regulatory ComplianceMARKING, Approvals and Supporting Documentation Mark/Approval DocumentationEMI Test Site Correlation Verification TestingRadio Frequency Emissions Radio Frequency Immunity RequirementsAcceptance Criteria Definitions Electrostatic Discharge ESDESD Requirements Acceptance Criteria DefinitionsContact Information Contact and Ordering InformationPage Index Manual Conventions Scope Page Modifications Certification and WarrantyLimited Warranty FCC Declaration of ConformityStec Inc World Headquarters