SimpleTech ZeusIOPS manual Drive Present, Devctrlcodex, Devctrlcoden Signal Definitions, Link Rate

Page 32

-DRIVE PRESENT

This signal is connected to the ground plane of the drive. The backplane can use this signal to detect the presence of the drive.

DEV_CTRL_CODE_X

The DEV_CTRL_CODE_2 through DEV_CTRL_CODE_0 signals provide a binary code to the drive to control functions such as FC link rate, Power Failure Warning (PFW) and Hard Reset. The control function is either identified by a code or a sequence of codes on the DEV_CTRL_CODE signals.

Table 9 lists the functions and the associated codes that use a decode value on the DEV_CTRL_CODE signals.

The Hard Reset function uses a sequence of values on the DEV_CTRL_CODE signals. The sequence is 5, 1, 3, 2, 3, 1 and 5. A drive detecting a valid Hard Reset sequence shall perform the equivalent of a power-on reset.

4.7K ohm pull-up resistors to 3.3V are provided on the drive for both DEV_CTRL_CODE_2,

DEV_CTRL_CODE_1 and DEV_CTRL_CODE_0 to ensure that each signal is maintained in its high state unless a low is provided from the backplane.

Note: Please refer to the SFF-8045 Specification for more information.

Table 9. DEV_CTRL_CODE_N Signal Definitions

 

DEV_CTRL_CODE_N

 

 

 

 

Link Rate

CODE_2

CODE_1

CODE_0

 

 

 

 

1.0625 GHz

1

1

1

 

 

 

 

2.1250 GHz

1

1

0

 

 

 

 

Reserved

1

0

1

 

 

 

 

Reserved

1

0

0

 

 

 

 

Reserved

0

1

1

 

 

 

 

Reserved

0

1

0

 

 

 

 

Reserved

0

0

1

 

 

 

 

Power Failure Warning

0

0

0

 

 

 

 

32

ZeusIOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

Image 32
Contents ZeusIOPS Fibre Channel Inch Solid State Drive Product Manual Export Administration Regulation Manual Conventions Page Revision History Revision Status Summary SheetPage Table of Contents Product Description Performance CharacteristicsElectrical Specifications Interface Specifications FC-AL FeaturesPhysical Characteristics Environmental CharacteristicsInstallation Fibre Channel StandardRegulatory Compliance Contact and Ordering InformationPage List of Tables Page List of Figures Page Product ID Code Capacity Approximate ScopeProduct ID Codes Standard Features Performance CharacteristicsElectrical Specifications Interface SpecificationsRegulatory Compliance InstallationFibre Channel Standard Reference Documents Download upgrades via the Fibre Channel interface Environmental Characteristics Product Description Performance Characteristics Data Transfer Rates Parameter Value UnitsErase Times Capacity Erase TimeSanitize Times and Standards Standard DoD 522.22-M Afssi NSA Capacity MinutesUnauthorized maintenance to the SSD will void the warranty Electrical Specifications Power SupplyPower Requirements Power ConsumptionGrounding Fault LED OUT SignalReady LED OUT Signal Selid Function Selid to Alpa TranslationSELN/PESIN Signal Definitions SFF-8045 Enclosure Service InterfaceSTARTn Mated Parallel ESI High Parallel ESI LowDevctrlcoden Signal Definitions Drive PresentDevctrlcodex Link RateInterface Specifications SSD OperationSCA-2 Interface Connector Relative SCA-2 Connector Location Pin SCA-2 Connector Pinout Voltage and Ground SignalsOption Support Loop ConnectionsFC-AL Supported Options FCP-SCSI Commands Command Code Command NameAllocation Length Report Luns CommandBit Byte Operation Code A0h Reserved Select Report Read 6 CDB Read 6 Command 08hTest Unit Ready CDB Code Reserved Allocation Length Control Write 6 CDBBit Byte Operation Code 0Ah Bit Byte Peripheral Qualifier Peripheral Device Type Device-Type ModifierVersion Ecma Version ANSI-approved Version Reserved Response Data Format AdditionalReserved Code Allocation Length Control Mode Sense CDBCode Field Descriptions Send Diagnostics CDB Parameter List LengthLog Sense Command Bit Byte OperationCode Reserved Parameter PointerRead Capacity CDB Read Extended 10 28h Read Extended 10 CDBBit Byte Operation Code 28h Logical Unit number Rsvd Reserved RelAdrReserve RelAdr Verify 10 2FhBit Byte Operation Code 2Ah Logical Unit Number Rsvd Write Buffer Command 3Bh Bit Byte Operation Code 3Bh Reserved Mode Buffer IDMode Value Description Buffer OffsetCode Description Subclause Code Field Descriptions for Mode SenseBit Byte Operation Code 5Ah Reserved Persistent Reserve Bit Byte Operation Code 5Eh Reserved Service ActionBit Byte Operation Code 5Fh Reserved Service Action Unsupported Mandatory Commands Command Command Code DescriptionFibre Channel Standard Fibre Channel Arbitrated LoopPage Fabric Node Connection Fabric Node ConnectionMonitoring ArbitrationOpen ClosedFCP Function Levels FCP Level DescriptionFormatted Capacities Physical CharacteristicsGeneral Physical Characteristics ZeusIOPS 3.5-Inch Dimensions Environmental Characteristics Temperature ConditionsOperating Temperatures Storage TemperaturesComponent Locations Maximum Component TemperaturesComponent Designator Maximum Package Temperature Installation System RequirementsDrive Configuration Power-On Fault Codes Flash Series ConditionOperational Fault Codes Code Condition DescriptionSelectid Configurations Bit Bits 5 Configuration ResultPossible Drive Orientations Suggested Air Flow Patterns for Cooling Exterior Mounting Specifications Underside Mounting Holes Side Mounting HolesDrive Installation Operating System Specifications Microsoft OS CompatibilitySSD Management Utility ZeusIOPS Management Utility RequirementsOperating System Web BrowserNand Flash Support Regulatory Compliance MARKING, Approvals and Supporting DocumentationMark/Approval Documentation Restriction of Hazardous MaterialsVerification Testing Radio Frequency EmissionsRadio Frequency Immunity Requirements EMI Test Site CorrelationElectrostatic Discharge ESD ESD RequirementsAcceptance Criteria Definitions Acceptance Criteria DefinitionsContact and Ordering Information Contact InformationPage Index Manual Conventions Scope Page Certification and Warranty Limited WarrantyFCC Declaration of Conformity ModificationsStec Inc World Headquarters