SimpleTech ZeusIOPS manual Power-On Fault Codes, Flash Series Condition

Page 64

POWER-ON FAULT CONDITIONS

The fault codes listed in Table 37 indicate that a fault has been detected during the power-on sequence. As a result, the unit is in a non-operational state and remedial action is required to replace the unit.

Power-on fault codes are indicated as a series of flashes. The fault light will illuminate for 0.25 seconds (250mS), then turn off for 0.25 seconds (250mS), followed by a 2 second off interval. The number of flashes between each 2 second off period is used to indicate the different fault conditions.

Table 37. Power-On Fault Codes

Flash Series

Condition

 

 

 

1

Flash

Memory strobe adjustment failure.

2

Flashes

Memory address failure.

3

Flashes

Memory data failure.

4

Flashes

ECC error encountered during memory test.

5

Flashes

ECC detection/correction circuit failure.

The fault code should be noted (along with the drive serial number if possible), and either the supplier of the SSD unit or technical support should be contacted.

64

ZeusIOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

Image 64
Contents ZeusIOPS Fibre Channel Inch Solid State Drive Product Manual Export Administration Regulation Manual Conventions Page Revision History Revision Status Summary SheetPage Table of Contents Electrical Specifications Performance CharacteristicsProduct Description Interface Specifications FC-AL FeaturesPhysical Characteristics Environmental CharacteristicsInstallation Fibre Channel StandardRegulatory Compliance Contact and Ordering InformationPage List of Tables Page List of Figures Page Product ID Codes ScopeProduct ID Code Capacity Approximate Standard Features Performance CharacteristicsElectrical Specifications Interface SpecificationsFibre Channel Standard InstallationRegulatory Compliance Reference Documents Download upgrades via the Fibre Channel interface Environmental Characteristics Product Description Performance Characteristics Data Transfer Rates Parameter Value UnitsErase Times Capacity Erase TimeSanitize Times and Standards Standard DoD 522.22-M Afssi NSA Capacity MinutesUnauthorized maintenance to the SSD will void the warranty Electrical Specifications Power SupplyPower Requirements Power ConsumptionReady LED OUT Signal Fault LED OUT SignalGrounding Selid Function Selid to Alpa TranslationSELN/PESIN Signal Definitions SFF-8045 Enclosure Service InterfaceSTARTn Mated Parallel ESI High Parallel ESI LowDevctrlcoden Signal Definitions Drive PresentDevctrlcodex Link RateInterface Specifications SSD OperationSCA-2 Interface Connector Relative SCA-2 Connector Location Pin SCA-2 Connector Pinout Voltage and Ground SignalsFC-AL Supported Options Loop ConnectionsOption Support FCP-SCSI Commands Command Code Command NameBit Byte Operation Code A0h Reserved Select Report Report Luns CommandAllocation Length Test Unit Ready CDB Read 6 Command 08hRead 6 CDB Bit Byte Operation Code 0Ah Write 6 CDBCode Reserved Allocation Length Control Bit Byte Peripheral Qualifier Peripheral Device Type Device-Type ModifierVersion Ecma Version ANSI-approved Version Reserved Response Data Format AdditionalCode Field Descriptions Mode Sense CDBReserved Code Allocation Length Control Send Diagnostics CDB Parameter List LengthLog Sense Command Bit Byte OperationCode Reserved Parameter PointerRead Capacity CDB Read Extended 10 28h Read Extended 10 CDBBit Byte Operation Code 28h Logical Unit number Rsvd Reserved RelAdrBit Byte Operation Code 2Ah Logical Unit Number Rsvd Verify 10 2FhReserve RelAdr Write Buffer Command 3Bh Bit Byte Operation Code 3Bh Reserved Mode Buffer IDMode Value Description Buffer OffsetBit Byte Operation Code 5Ah Reserved Code Field Descriptions for Mode SenseCode Description Subclause Bit Byte Operation Code 5Fh Reserved Service Action Bit Byte Operation Code 5Eh Reserved Service ActionPersistent Reserve Unsupported Mandatory Commands Command Command Code DescriptionFibre Channel Standard Fibre Channel Arbitrated LoopPage Fabric Node Connection Fabric Node ConnectionMonitoring ArbitrationOpen ClosedFCP Function Levels FCP Level DescriptionGeneral Physical Characteristics Physical CharacteristicsFormatted Capacities ZeusIOPS 3.5-Inch Dimensions Environmental Characteristics Temperature ConditionsOperating Temperatures Storage Temperatures Component Designator Maximum Package Temperature Maximum Component Temperatures Component Locations Installation System RequirementsDrive Configuration Power-On Fault Codes Flash Series ConditionOperational Fault Codes Code Condition DescriptionSelectid Configurations Bit Bits 5 Configuration ResultPossible Drive Orientations Suggested Air Flow Patterns for Cooling Exterior Mounting Specifications Underside Mounting Holes Side Mounting HolesDrive Installation Operating System Specifications Microsoft OS CompatibilitySSD Management Utility ZeusIOPS Management Utility RequirementsOperating System Web BrowserNand Flash Support Regulatory Compliance MARKING, Approvals and Supporting DocumentationMark/Approval Documentation Restriction of Hazardous MaterialsVerification Testing Radio Frequency EmissionsRadio Frequency Immunity Requirements EMI Test Site CorrelationElectrostatic Discharge ESD ESD RequirementsAcceptance Criteria Definitions Acceptance Criteria DefinitionsContact and Ordering Information Contact InformationPage Index Manual Conventions Scope Page Certification and Warranty Limited WarrantyFCC Declaration of Conformity ModificationsStec Inc World Headquarters