SimpleTech ZeusIOPS manual Loop Connections, FC-AL Supported Options, Option Support

Page 37

FC-AL FEATURES

LOOP CONNECTIONS

The ZeusIOPS 3.5-inch Fibre Channel SSD features two independent FC-AL ports. These ports may be connected in different loops or the same loop. In addition, the drive can send transfers while receiving frames on both ports. This capability is called “full-duplex”.

If the ports are 1) connected in different loops, 2) hard addressing is used, and 3) the drive interface address is selected through the interface connector, then both ports will seek the same loop address. If there are no duplicate addresses on the different loops, both ports will use the same address.

If the ports are 1) connected in the same loop and 2) hard addressing is used, the drive reads the settings from the connector. If the SCA connector is configured for a hard address, only one of the ports will be seen on the loop; only one port can acquire the ID.

If the drive has 1) its ports connected to different loops, and 2) buffer availability, then the drive is able to receive transfers on both ports at the same time. This capability is called “concurrent port transfers”.

Table 11 summarizes the FC-AL options supported by the drive.

 

Table 11. FC-AL Supported Options

 

 

Option

Support

 

 

OPEN Half Duplex

Accepted from another device

 

 

OPEN Full Duplex

Sent to open another device; accepted from another device

 

 

Private Loop

Supported

 

 

Public Loop

Supported

 

 

Old Port State

Not supported

 

 

Loop Position

Supported

 

 

Loop Position Report

Supported

 

 

ZeusIOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

37

Image 37
Contents ZeusIOPS Fibre Channel Inch Solid State Drive Product Manual Export Administration Regulation Manual Conventions Page Revision Status Summary Sheet Revision HistoryPage Table of Contents Electrical Specifications Performance CharacteristicsProduct Description FC-AL Features Interface SpecificationsEnvironmental Characteristics Physical CharacteristicsInstallation Fibre Channel StandardContact and Ordering Information Regulatory CompliancePage List of Tables Page List of Figures Page Product ID Codes ScopeProduct ID Code Capacity Approximate Performance Characteristics Standard FeaturesElectrical Specifications Interface SpecificationsFibre Channel Standard InstallationRegulatory Compliance Reference Documents Download upgrades via the Fibre Channel interface Environmental Characteristics Product Description Performance Characteristics Parameter Value Units Data Transfer RatesCapacity Erase Time Erase TimesSanitize Times and Standards Standard DoD 522.22-M Afssi NSA Capacity MinutesUnauthorized maintenance to the SSD will void the warranty Power Supply Electrical SpecificationsPower Requirements Power ConsumptionReady LED OUT Signal Fault LED OUT SignalGrounding Selid to Alpa Translation Selid FunctionSFF-8045 Enclosure Service Interface SELN/PESIN Signal DefinitionsSTARTn Mated Parallel ESI High Parallel ESI LowDrive Present Devctrlcoden Signal DefinitionsDevctrlcodex Link RateSSD Operation Interface Specifications SCA-2 Interface Connector Relative SCA-2 Connector Location Voltage and Ground Signals Pin SCA-2 Connector PinoutFC-AL Supported Options Loop ConnectionsOption Support Command Code Command Name FCP-SCSI CommandsBit Byte Operation Code A0h Reserved Select Report Report Luns CommandAllocation Length Test Unit Ready CDB Read 6 Command 08hRead 6 CDB Bit Byte Operation Code 0Ah Write 6 CDBCode Reserved Allocation Length Control Device-Type Modifier Bit Byte Peripheral Qualifier Peripheral Device TypeVersion Ecma Version ANSI-approved Version Reserved Response Data Format AdditionalCode Field Descriptions Mode Sense CDBReserved Code Allocation Length Control Parameter List Length Send Diagnostics CDBBit Byte Operation Log Sense CommandCode Reserved Parameter PointerRead Capacity CDB Read Extended 10 CDB Read Extended 10 28hBit Byte Operation Code 28h Logical Unit number Rsvd Reserved RelAdrBit Byte Operation Code 2Ah Logical Unit Number Rsvd Verify 10 2FhReserve RelAdr Bit Byte Operation Code 3Bh Reserved Mode Buffer ID Write Buffer Command 3BhMode Value Description Buffer OffsetBit Byte Operation Code 5Ah Reserved Code Field Descriptions for Mode SenseCode Description Subclause Bit Byte Operation Code 5Fh Reserved Service Action Bit Byte Operation Code 5Eh Reserved Service ActionPersistent Reserve Command Command Code Description Unsupported Mandatory CommandsFibre Channel Arbitrated Loop Fibre Channel StandardPage Fabric Node Connection Fabric Node ConnectionArbitration MonitoringOpen ClosedFCP Level Description FCP Function LevelsGeneral Physical Characteristics Physical CharacteristicsFormatted Capacities ZeusIOPS 3.5-Inch Dimensions Temperature Conditions Environmental CharacteristicsOperating Temperatures Storage TemperaturesComponent Designator Maximum Package Temperature Maximum Component TemperaturesComponent Locations System Requirements InstallationDrive Configuration Flash Series Condition Power-On Fault CodesCode Condition Description Operational Fault CodesBit Bits 5 Configuration Result Selectid ConfigurationsPossible Drive Orientations Suggested Air Flow Patterns for Cooling Underside Mounting Holes Side Mounting Holes Exterior Mounting SpecificationsDrive Installation Microsoft OS Compatibility Operating System SpecificationsZeusIOPS Management Utility Requirements SSD Management UtilityOperating System Web BrowserNand Flash Support MARKING, Approvals and Supporting Documentation Regulatory ComplianceMark/Approval Documentation Restriction of Hazardous MaterialsRadio Frequency Emissions Verification TestingRadio Frequency Immunity Requirements EMI Test Site CorrelationESD Requirements Electrostatic Discharge ESDAcceptance Criteria Definitions Acceptance Criteria DefinitionsContact Information Contact and Ordering InformationPage Index Manual Conventions Scope Page Limited Warranty Certification and WarrantyFCC Declaration of Conformity ModificationsStec Inc World Headquarters