SimpleTech ZeusIOPS manual Scope

Page 81

S

 

Scope

 

Audience

18

Manual Overview

17

Product ID Codes

17

SCSI Commands

 

Inquiry Command (12h)

41

Log Sense (4Dh)

45

Mode Sense (10) Command (5Ah) 50

Mode Sense (6) Command (1Ah) 43

Persistent Reserve In (5Eh)

51

Persistent Reserve Out (5Fh)

51

Read (6) (08h)

40

Read Capacity (25h)

46

Read Extended (10) (28h)

47

Release (10) Command (57h)

..... 50

Release (6) Command (17h)

43

Report Luns (A0h)

38, 39

Send Diagnostic Page (1Dh)

44

Synchronize Cache (10) (35h)

.... 49

Test Unit Ready

40

Unsupported Commands

52

Verify (10) (2Fh)

48

Write (6) Command (0Ah)

41

Write and Verify (10) (2Eh)

48

Write Buffer (3Bh)

49

Write Extended (10) (2Ah)

48

Standard Features

 

Environmental

22

Firmware Upgrades

21

Interface Standard

20

Introduction

20

Media

21

Performance

21

Physical

21

Power

22

Reliability

21

Unformatted Capacities

21

T

 

Trademark Information

ii

U

 

Unsupported SCSI Commands

 

Format Unit

52

Request Sense

52

W

 

Warranty

 

Limited

81

Modifications

81

ZeusIOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev 1.0

79

Image 81
Contents ZeusIOPS Fibre Channel Inch Solid State Drive Product Manual Export Administration Regulation Manual Conventions Page Revision Status Summary Sheet Revision HistoryPage Table of Contents Performance Characteristics Electrical SpecificationsProduct Description FC-AL Features Interface SpecificationsEnvironmental Characteristics Physical CharacteristicsInstallation Fibre Channel StandardContact and Ordering Information Regulatory CompliancePage List of Tables Page List of Figures Page Scope Product ID CodesProduct ID Code Capacity Approximate Performance Characteristics Standard FeaturesElectrical Specifications Interface SpecificationsInstallation Fibre Channel StandardRegulatory Compliance Reference Documents Download upgrades via the Fibre Channel interface Environmental Characteristics Product Description Performance Characteristics Parameter Value Units Data Transfer RatesCapacity Erase Time Erase TimesSanitize Times and Standards Standard DoD 522.22-M Afssi NSA Capacity MinutesUnauthorized maintenance to the SSD will void the warranty Power Supply Electrical SpecificationsPower Requirements Power ConsumptionFault LED OUT Signal Ready LED OUT SignalGrounding Selid to Alpa Translation Selid FunctionSFF-8045 Enclosure Service Interface SELN/PESIN Signal DefinitionsSTARTn Mated Parallel ESI High Parallel ESI LowDrive Present Devctrlcoden Signal DefinitionsDevctrlcodex Link RateSSD Operation Interface SpecificationsSCA-2 Interface Connector Relative SCA-2 Connector Location Voltage and Ground Signals Pin SCA-2 Connector PinoutLoop Connections FC-AL Supported OptionsOption Support Command Code Command Name FCP-SCSI CommandsReport Luns Command Bit Byte Operation Code A0h Reserved Select ReportAllocation Length Read 6 Command 08h Test Unit Ready CDBRead 6 CDB Write 6 CDB Bit Byte Operation Code 0AhCode Reserved Allocation Length Control Device-Type Modifier Bit Byte Peripheral Qualifier Peripheral Device TypeVersion Ecma Version ANSI-approved Version Reserved Response Data Format AdditionalMode Sense CDB Code Field DescriptionsReserved Code Allocation Length Control Parameter List Length Send Diagnostics CDBBit Byte Operation Log Sense CommandCode Reserved Parameter PointerRead Capacity CDB Read Extended 10 CDB Read Extended 10 28hBit Byte Operation Code 28h Logical Unit number Rsvd Reserved RelAdrVerify 10 2Fh Bit Byte Operation Code 2Ah Logical Unit Number RsvdReserve RelAdr Bit Byte Operation Code 3Bh Reserved Mode Buffer ID Write Buffer Command 3BhMode Value Description Buffer OffsetCode Field Descriptions for Mode Sense Bit Byte Operation Code 5Ah ReservedCode Description Subclause Bit Byte Operation Code 5Eh Reserved Service Action Bit Byte Operation Code 5Fh Reserved Service ActionPersistent Reserve Command Command Code Description Unsupported Mandatory CommandsFibre Channel Arbitrated Loop Fibre Channel StandardPage Fabric Node Connection Fabric Node ConnectionArbitration MonitoringOpen ClosedFCP Level Description FCP Function LevelsPhysical Characteristics General Physical CharacteristicsFormatted Capacities ZeusIOPS 3.5-Inch Dimensions Temperature Conditions Environmental CharacteristicsOperating Temperatures Storage TemperaturesMaximum Component Temperatures Component Designator Maximum Package TemperatureComponent Locations System Requirements InstallationDrive Configuration Flash Series Condition Power-On Fault CodesCode Condition Description Operational Fault CodesBit Bits 5 Configuration Result Selectid ConfigurationsPossible Drive Orientations Suggested Air Flow Patterns for Cooling Underside Mounting Holes Side Mounting Holes Exterior Mounting SpecificationsDrive Installation Microsoft OS Compatibility Operating System SpecificationsZeusIOPS Management Utility Requirements SSD Management UtilityOperating System Web BrowserNand Flash Support MARKING, Approvals and Supporting Documentation Regulatory ComplianceMark/Approval Documentation Restriction of Hazardous MaterialsRadio Frequency Emissions Verification TestingRadio Frequency Immunity Requirements EMI Test Site CorrelationESD Requirements Electrostatic Discharge ESDAcceptance Criteria Definitions Acceptance Criteria DefinitionsContact Information Contact and Ordering InformationPage Index Manual Conventions Scope Page Limited Warranty Certification and WarrantyFCC Declaration of Conformity ModificationsStec Inc World Headquarters