PROBLEM | POSSIBLE CAUSE |
| REMEDY | ||||
[5] No water | a) Water Supply Line |
|
| 1. Water pressure too low and | 1. Check and get | ||
comes from |
|
|
|
| water level in Water Tank |
| recommended pressure. |
Spray Tubes. |
|
|
|
| too low. |
|
|
Water Pump | b) Water Solenoid | 1. | Dirty mesh filter or orifice | 1. Clean. | |||
will not start, or | Valve |
|
|
| and water level in Water |
|
|
freeze cycle |
|
|
|
| Tank too low. |
|
|
time is too | c) Water System |
|
| 1. Water leaks. | 1. Check connections for | ||
short. |
|
|
|
|
|
| water leaks, and replace. |
|
|
|
| 2. Clogged. | 2. Clean. | ||
|
|
|
| 3. Pump Out Check Valve | 3. Check assembly and | ||
|
|
|
|
| leaking by. |
| clean. |
| d) Pump Motor |
|
| 1. Motor winding opened. | 1. Replace. | ||
|
| 2. | Bearing worn out. | 2. Replace. | |||
|
| 3. | Wiring to Pump Motor. | 3. | Check for loose | ||
|
|
|
|
|
|
| connection or open, and |
|
|
|
|
|
|
| replace. |
|
| 4. | Defective Capacitor. | 4. | Replace. | ||
|
|
|
| 5. | Defective or bound impeller. | 5. | Replace and clean. |
|
| 6. | Mechanical Seal worn out. | 6. | Check and replace. | ||
| e) Controller Board | 1. | Defective. | 1. | See “II.2. [e] CHECKING | ||
|
|
|
|
|
|
| CONTROLLER BOARD.” |
[6] Fan Motor will | a) Fan Motor |
|
| 1. Motor winding opened. | 1. Replace. | ||
not start, or is |
| 2. | Bearing worn out. | 2. | Replace. | ||
not operating. |
| 3. | Wiring to Fan Motor. | 3. | Check for loose | ||
|
|
|
|
|
|
| connection or open, and |
|
|
|
|
|
|
| replace. |
|
|
| 4. | Defective Capacitor. | 4. | Replace. | |
|
|
|
| 5. Fan blade bound. | 5. | Check and replace. | |
| b) Controller Board | 1. | Defective. | 1. | See “II.2. [e] CHECKING | ||
|
|
|
|
|
|
| CONTROLLER BOARD.” |
[7] All components | a) Refrigerant |
|
| 1. Undercharged. | 1. | Check for leaks and | |
run but no ice |
|
|
|
|
|
| recharge. |
is produced. |
| 2. | Air or moisture trapped. | 2. | Replace Drier, and | ||
|
|
|
|
|
|
| recharge. |
| b) Compressor | 1. | Defective valve. | 1. Replace. | |||
| c) Hot Gas Solenoid | 1. | Continues to open in freeze | 1. | Check and replace. | ||
| Valve |
|
|
| cycle. |
|
|
| d) Line Valve | 1. | Continues to close in | 1. | Check and replace | ||
|
|
|
|
| freeze cycle. |
|
|
| e) Water Solenoid | 1. | Water Solenoid Valve is | 1. Check for water leaks | |||
| Valve |
|
|
| open during freeze. |
| with icemaker off. |
29