2. EVAPORATOR IS FROZEN UP
PROBLEM | POSSIBLE CAUSE |
| REMEDY | |||
[1] Freeze cycle | a) Float Switch | 1. | Leads | 1. | Check and replace. | |
time is too |
|
|
| defective switch. |
|
|
long. |
|
| 2. | Float does not move freely. | 2. | Clean or replace. |
| b) Water Solenoid | 1. | Diaphragm does not close. | 1. Check for water leaks | ||
| Valve |
|
|
| with icemaker off. | |
| c) Controller Board | 1. Defective. | 1. | See “II.2[e] CHECKING | ||
|
|
|
|
|
| CONTROLLER BOARD.” |
[2] All ice formed | a) Evaporator | 1. | Scaled up. | 1. | Clean. | |
on Evaporator |
|
|
|
|
|
|
b) Water Supply Line | 1. | Water pressure too low. | 1. | Check and get | ||
does not fall |
|
|
|
|
| recommended pressure. |
into bin in | c) Water Filter System | 1. Dirty/Restricted. | 1. | Replace filter. | ||
harvest cycle. | d) Water Solenoid | 1. | Dirty mesh filter or orifice. | 1. | Clean. | |
| Valve |
|
|
|
| |
| e) Ambient and/or | 1. | Too cool. | 1. Increase temperature. | ||
| water temperature |
|
|
|
| |
| f) Line Valve | 1. | Continues to open in | 1. | Check operation in | |
|
|
|
| harvest cycle. |
| harvest cycle and replace. |
| g) Thermistor | 1. Out of position or loose | 1. | See “V. 9. REMOVAL | ||
|
|
|
| attachment. |
| AND REPLACEMENT OF |
|
|
|
|
|
| THERMISTOR.” |
| h) Controller Board | 1. | Defrost Timer is set too | 1. | Adjust longer, referring | |
|
|
|
| short. |
| to “II. 2. [d] CONTROLS |
|
|
|
|
|
| AND ADJUSTMENT, 2) |
|
|
|
|
|
| Defrost Timer.” |
|
|
| 2. Defective. | 2. | See “II. 2.[e] CHECKING | |
|
|
|
|
|
| CONTROLLER BOARD.” |
[3] Others | a) Spray Tubes | 1. Clogged. | 1. Clean. | |||
|
|
| 2. | Out of position. | 2. | Place in position. |
| b) Water System | 1. | Dirty. | 1. | Clean. | |
| c) Refrigerant | 1. Undercharged. | 1. | Check for leaks and | ||
|
|
|
|
|
| recharge. |
| d) Expansion Valve | 1. | Bulb out of position or | 1. | Place in position. | |
|
|
|
| loose attachment. |
|
|
|
|
| 2. Defective. | 2. | Replace. | |
| e) Hot Gas Solenoid | 1. Coil winding opened. | 1. Replace. | |||
| Valve |
| 2. | Plunger does not move. | 2. Replace. | |
|
|
| 3. | Wiring to Hot Gas Valve. | 3. | Check for loose |
|
|
|
|
|
| connection or open, and |
|
|
|
|
|
| replace. |
| f) Water Supply Line | 1. | Too small; requires 1/2" OD | 1. | Increase water line size. | |
|
|
|
| line dedicated per machine. |
|
|
| g) Water filter | 1. | Flow rate too small. | 1. | Replace with filter that | |
|
|
|
|
|
| has larger flow rate. |
|
|
|
|
|
|
|
30