Hoshizaki KM-2400SRF3, KM-2400SRH3 service manual Removal and Replacement of Water Valve

Page 42

11. REMOVAL AND REPLACEMENT OF WATER VALVE

1)Turn off the power supply.

2)Close the Water Supply Line Shut-off Valve.

3)Remove the Front Panel.

4)Remove the Valve Outlet Tubing by releasing the Clamp.

5)Remove the Bracket from the unit.

6)Remove the Fitting Nut and Water Valve.

7)Disconnect the Terminals from the Water Valve.

8)Install the new Water Valve, and replace the removed parts in the reverse order of which they were removed.

9)Open the Water Supply Line Shut-off Valve.

10)Turn on the power supply.

11)Check for leaks.

12)Replace the Front Panel in its correct position.

12.REMOVAL AND REPLACEMENT OF PUMP MOTOR

1)Turn off the power supply.

2)Remove the Front Panel.

3)Drain the Water Tank by removing the Insulation Panel and the cap at the front of the ice dropping hole.

See Fig. 2.

4)Replace the removed parts in their correct positions.

5)Disconnect the Pump Suction and Discharge Hoses.

6)Remove the screws and the Pump Motor Bracket.

Fig. 2

42

Image 42
Contents Stackable Crescent Cuber Hoshizaki AMERICA, INC Contents Maintenance Specifications Condensing UNIT, URC-24F Specifications Model URC-24F II. General Information Construction SOLID-STATE Control Features of Control Products E Controller BoardController Board Controller BoardPage Harvest Cycle Beep every 3 sec. = High Evaporator Temperature 127 FMinute Fill Cycle Freeze CycleControl Products HOSHIZAKI001 Board Control Products HOS-001A Board Sequence 1st Cycle 2nd Cycle and after with pump drain Important Water Valve opening is limited to 6 minutes2nd Cycle and after with no pump drain Controls and Adjustments OFFSetting Time Setting Frequency Checking the Controller Board Page III. Technical Information Wiring Diagram Timing Chart Page Performance Data IV. Service Diagnosis No ICE Production Problem Possible Cause RemedyController Board Problem Possible Cause Remedy Evaporator is Frozen UP ThermistorLOW ICE Production Abnormal ICEOthers Refrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-404ABrazing Removal and Replacement of Compressor Important Removal and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of HOT GAS Valve and Line Valve Removal and Replacement of Evaporator Important Page Removal and Replacement of Thermistor Caution Removal and Replacement of FAN Motor Removal and Replacement of Water Valve Removal and Replacement of Pump MotorRemoval and Replacement of Spray Tubes VI. Cleaning and Maintenance Instructions Important Preparing the Icemaker for Long StoragePage Cleaning Procedure Cleaning Procedure Page Sanitizing Procedure Following Cleaning Procedure Maintenance