FieldServer FS-8700-39 Appendix C. EST3 Data Format Appendix C.1. Input data format

Page 17

FS-8700-39 EST3 Driver Manual

Page 17 of 21

 

 

Appendix C. EST3 Data Format:

Appendix C.1. Input data format

Each input device is associated with a 16-bit value. The contents of the 16 bits are used to generate status types as shown in the table below. Each incoming event is allocated to a status type depending on its device type as shown in the table. It is possible to override this default status type allocation. Refer to Appendix A.5 for more information.

Type

Encode

Alarm

Trouble

Supervisory

Monitor

Others

 

Value

 

 

 

 

 

Smoke

0

Y

 

 

 

 

 

 

 

 

 

 

 

Pull

1

Y

 

 

 

 

 

 

 

 

 

 

 

Heat

2

Y

 

 

 

 

 

 

 

 

 

 

 

Waterflow

3

Y

 

 

 

 

 

 

 

 

 

 

 

Stageone

4

Y

 

 

 

 

 

 

 

 

 

 

 

Zone

5

Y

 

 

 

 

 

 

 

 

 

 

 

AlarmVerify

6

 

Y

 

 

 

 

 

 

 

 

 

 

PreAlarm

7

 

Y

 

 

 

 

 

 

 

 

 

 

Security

8

 

Y

 

 

 

 

 

 

 

 

 

 

Station

9

 

 

 

 

Y

 

 

 

 

 

 

 

Emergency

10

 

Y

 

 

 

 

 

 

 

 

 

 

Supervisory

11

 

 

Y

 

 

 

 

 

 

 

 

 

Valve

12

 

 

Y

 

 

 

 

 

 

 

 

 

GateValve

13

 

 

Y

 

 

 

 

 

 

 

 

 

Tamper

14

 

 

Y

 

 

 

 

 

 

 

 

 

Temperature

15

 

 

Y

 

 

 

 

 

 

 

 

 

Power

16

 

 

Y

 

 

Signal

17

 

 

Y

 

 

 

 

 

 

 

 

 

TroubleOpen

18

 

Y

 

 

 

TroubleShort

19

 

Y

 

 

 

 

 

 

 

 

 

 

LocalTrouble

20

 

Y

 

 

 

MaintAlert

21

 

Y

 

 

 

 

 

 

 

 

 

 

DirtyHead

22

 

Y

 

 

 

 

 

 

 

 

 

 

DeviceComm

23

 

Y

 

 

 

 

 

 

 

 

 

 

GroundFault

24

 

Y

 

 

 

 

 

 

 

 

 

 

InternalTrouble

25

 

Y

 

 

 

 

 

 

 

 

 

 

BadType

26

 

Y

 

 

 

 

 

 

 

 

 

 

BadPersonality

27

 

Y

 

 

 

 

 

 

 

 

 

 

UnexpectedDevice

28

 

Y

 

 

 

 

 

 

 

 

 

 

CommonTrouble

29

 

Y

 

 

 

 

 

 

 

 

 

 

RelayConfirmation

30

 

 

 

 

Y

 

 

 

 

 

 

 

Monitor

31

 

 

 

Y

 

 

 

 

 

 

 

 

LocalMonitor

32

 

 

 

Y

 

 

 

 

 

 

 

 

Damper

33

 

 

 

Y

 

Fan

34

 

 

 

Y

 

 

 

 

 

 

 

 

Door

35

 

 

 

Y

 

 

 

 

 

 

 

 

Switch

36

 

 

 

 

Y

 

 

 

 

 

 

 

FirePhone

37

 

Y

 

 

 

 

 

 

 

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

Image 17
Contents Applicability & Effectivity Driver Manual FS-8700-39 EST3 ECPTable of Contents EST3 Description Required 3rd Party ConfigurationProvided By the Supplier of 3rd Party Equipment Hardware ECP Type III with TextFieldServerP1 Hardware ConnectionsUINT16 Configuring the FieldServer as a EST3 ClientData Arrays Client Side Node Descriptors Client Side Connection DescriptorsEST3 EST1 EST3RDBC, Wrbc 3, Wrbx Driver Related Map Descriptor ParametersPage Map Descriptor Example Appendix A.4. Report and Delta Service Appendix A.2. Setting up Multiple ParametersAppendix A. Driver Notes Appendix A.1. PanelMasks Appendix A.3. PriorityDaalarm Appendix A.4.1. Example Configuration using Delta Mode onlyDATEST1 DatroubleAppendix A.5. Optional Data Arrays Appendix A.5.3. ESTTypesUpdateAppendix A.5.1. Relay Confirmation State Appendix A.5.2. ESTTypesDAAppendix A.5.5. ESTReportType Partition Appendix A.6. Object Types and Required ParametersAppendix A.7. Set Date and Time To Panel FS-8700-39 EST3 Driver Manual Appendix C. EST3 Data Format Appendix C.1. Input data format Page Appendix C.2. Output data format Appendix D. EST3 ECP Connection Statistics Appendix E. Driver Error Messages