FieldServer FS-8700-19 HR1, LR1, HR2, LR2, HR3, LR3, HR4, LR4, HR5, LR5, HR6, LR6, HR7, LR7, HR8

Page 38

FS-8700-19_Metasys_N2 Driver Manual

 

 

 

 

Page 38 of 51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 0

 

 

 

 

 

 

Item

Item

 

Signal Condition

Read/Write

Johnson

 

Description

 

 

 

 

DEC

HEX

 

Tag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

231

E7

 

Byte

 

Write

 

OMS4

 

Source of logic output module OUTB

 

 

 

232

E8

 

Byte

 

Write

 

OMTY1

 

Output module type

 

 

 

233

E9

 

FP

 

Write

 

FST1

 

PAT/DAT output 1 timing

 

 

 

234

EA

 

FP

 

Write

 

DB1

 

Dead band PAT output 1

 

 

 

235

EB

 

FP

 

Write

 

OH5

 

Output OUTA2 high range

 

 

 

236

EC

 

FP

 

Write

 

OL5

 

Output OUTA2 low range

 

 

 

237

ED

 

Byte

 

Write

 

OMS5

 

Source of logic output module OUTA

 

 

 

238

EE

 

Byte

 

Write

 

OMS6

 

Source of logic output module OUTB

 

 

 

239

EF

 

Byte

 

Write

 

OMTY2

 

Output module type

 

 

 

240

F0

 

FP

 

Write

 

FST2

 

PAT/DAT output 2 timing

 

 

 

241

F1

 

FP

 

Write

 

DB2

 

Dead band PAT output 2

 

 

 

242

F2

 

FP

 

Write

 

OH7

 

Output OUTA3 high range

 

 

 

243

F3

 

FP

 

Write

 

OL7

 

Output OUTA3 low range

 

 

 

244

F4

 

Byte

 

Write

 

OMS7

 

Source of logic output module OUTA

 

 

 

245

F5

 

Byte

 

Write

 

OMS8

 

Source of logic output module OUTB

 

 

 

246

F6

 

Byte

 

Write

 

OMty3

 

Output module type

 

 

 

247

F7

 

FP

 

Write

 

FST3

 

PAT/DAT output 3 timing

 

 

 

248

F8

 

FP

 

Write

 

DB3

 

Dead band PAT output 3

 

 

 

249

F9

 

FP

 

Write

 

SB1

 

Symmetry band controller module 5

 

 

 

250

FA

 

FP

 

Write

 

SB2

 

Symmetry band controller module 6

 

 

 

251

FB

 

Byte

 

Write

 

ALDIS

 

Alarm disable condition source

 

 

 

252

FC

 

Byte

 

Write

 

RCTY1

 

DC type settings

 

 

 

253

FD

 

Byte

 

Write

 

ALGT

 

Standard algorithm type

 

 

 

254

FE

 

FP

 

Write

 

COS1

 

Spare constant

 

 

 

255

FF

 

FP

 

Write

 

COS2

 

Spare constant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 1

 

 

 

 

 

 

Relative Item

Signal Condition

Read/Write

Johnson Tag

 

Description

Relative Item

 

 

 

 

0

0

FP

 

Write

 

HR1

High range analog input 1

 

 

 

 

1

1

FP

 

Write

 

LR1

Low range analog input 1

 

 

 

 

2

2

FP

 

Write

 

HR2

High range analog input 2

 

 

 

 

3

3

FP

 

Write

 

LR2

Low range analog input 2

 

 

 

 

4

4

FP

 

Write

 

HR3

High range analog input 3

 

 

 

 

5

5

FP

 

Write

 

LR3

Low range analog input 3

 

 

 

 

6

6

FP

 

Write

 

HR4

High range analog input 4

 

 

 

 

7

7

FP

 

Write

 

LR4

Low range analog input 4

 

 

 

 

8

8

FP

 

Write

 

HR5

High range analog input 5

 

 

 

 

9

9

FP

 

Write

 

LR5

Low range analog input 5

 

 

 

 

10

A

FP

 

Write

 

HR6

High range analog input 6

 

 

 

 

11

B

FP

 

Write

 

LR6

Low range analog input 6

 

 

 

 

12

C

FP

 

Write

 

HR7

High range analog input 7

 

 

 

 

13

D

FP

 

Write

 

LR7

Low range analog input 7

 

 

 

 

14

E

FP

 

Write

 

HR8

High range analog input 8

 

 

 

 

15

F

FP

 

Write

 

LR8

Low range analog input 8

 

 

 

 

16

10

FP

 

Write

 

OM%1

Output % Output module 1

 

 

 

 

17

11

FP

 

Write

 

OM%2

Output % Output module 2

 

 

 

 

18

12

FP

 

Write

 

OM%3

Output % Output module 3

 

 

 

 

19

13

FP

 

Write

 

OM%4

Output % Output module 4

 

 

 

 

20

14

FP

 

Write

 

OM%5

Output % Output module 5

 

 

 

 

21

15

FP

 

Write

 

OM%6

Output % Output module 6

 

 

 

 

22

16

FP

 

Write

 

OM%7

Output % Output module 7

 

 

 

 

23

17

FP

 

Write

 

OM%8

Output % Output module 8

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 38
Contents FS-8700-19 Metasys N2 Table of Contents Metasys N2 Description Required 3rd Party Software Required 3rd Party ConfigurationProvided by the Supplier of 3rd Party Equipment Hardware Hardware Connections Hardware Connection Tips / HintsConfiguring the FieldServer as a Metasys N2 Client Data Arrays/DescriptorsClient Side Connection Descriptions Client Side Node Descriptors AI, AO, DI, do Object Configuration VMA Map Descriptor Parameters ADF ADI 2.3. DX9100 Map Descriptor Parameters Timing ParametersMap Descriptor Example 1 N2Open Map Descriptor Example 2 VMAMap Descriptor Example 3 DX9100 DAAO3 WrbxConfiguring the FieldServer as a Metasys N2 Server Server Side Connection DescriptorsServer Side Node Descriptors Driver Specific Map Descriptor Parameters Map Descriptor Example FS-8700-19MetasysN2 Driver Manual Appendix A.2. Managing Analog Inputs and Outputs for DX9100 Appendix B.2. Offline Behavior Appendix B.3. Tip on OverridesFS-8700-19MetasysN2 Driver Manual FS-8700-19MetasysN2 Driver Manual Appendix C.3. Configuration Settings Appendix C.2. Hardware connectionsFS-8700-19MetasysN2 Driver ManualPage 26 MNT UnitSUP DiagPMF1 PmtypPmopt PMF2PMK34 PMK32PMK33 PMOU1FB@ DOTDO@ DOF@XTHIA7 XTHIA6XTLOA6 XTLOA7FS-8700-19MetasysN2 Driver Manual Appendix D.2. Metasys DC9100 Memory Map DEC HEXTYPE1 TYPE3 TYPE6 TYPE8 HR2 HR1LR1 LR2OSOT@ OsoptOSZT@ OSSP@Appendix D.3. Metasys TC9100 Memory Map Mods DO6 Triac DO7 DO1 DO2ROS ModtIAS LSCRAS AFMPM5K3 PM5TYPPM5K2 PM5K4OCO4 OCO3OCN4 OCN5TCS1 TCS2TCS3 HDW1OFS1 LRI1FTC1 IOP1Fdif FT@FSP LOODST3 DST1DST2 DST4DST7 DST5DST6 Appendix E. Error Messages Error Message Description and ActionThis page Intentionally Left Blank