FieldServer FS-8700-17 instruction manual Specified module positions get set

Page 23

 

FS-8700-17 Optomux

 

 

Driver Manual

 

Read/

COMMAND NAME

OPTO22_FORMAT

MASTER LENGTH

NOTES

Write/

 

OPTION

CONSIDERED (See

 

 

Both

 

 

Notes)

 

 

 

 

 

Specified) module positions get set

 

 

 

 

 

 

 

 

 

 

off->on

w

SET LATCH OFF TO ON

 

3

Only module positions specified get

 

 

 

 

 

affected by command.

w

SET LATCH ON TO OFF

 

3

Only module positions specified get

 

 

 

 

 

affected by command.

r

READ LATCHES

1

2

If format=Bit then length is considered

 

 

 

 

 

during storage as bits are unpacked

 

 

 

 

 

into data array. If format is non equal

 

 

 

 

 

to bit then result is written as a single

 

 

 

 

 

value into one array element.

b

READ AND CLEAR LATCHES

1

3,2

Non-zero (Specified) module

 

 

 

 

 

positions get affected (cleared) by

 

 

 

 

 

command. But all positions get read.

 

 

 

 

 

Read data get stored in data array.

 

 

 

 

 

During storage opto22_format is

 

 

 

 

 

considered. If format=bit then data is

 

 

 

 

 

unpacked and stored otherwise the

 

 

 

 

 

result for all 16 positions is stored as

 

 

 

 

 

one data element.

w

CLEAR LATCHES

 

3

Only module positions specified get

 

 

 

 

 

affected by command.

w

START/STOP COUNTERS

 

3

All positions are affected by

 

 

 

 

 

command. Non-zero (specified)

 

 

 

 

 

module positions start counting, zero

 

 

 

 

 

(unspecified) module positions stop

 

 

 

 

 

counting

w

START COUNTERS

 

3

Only module positions specified get

 

 

 

 

 

affected by command.

w

STOP COUNTERS

 

3

Only module positions specified get

 

 

 

 

 

affected by command.

r

READ COUNTERS

 

1

Data that is read is put into the

 

 

 

 

 

corresponding array elements of the

 

 

 

 

 

data array based on which module

 

 

 

 

 

positions are read.

b

READ AND CLEAR COUNTERS

 

1

Data that is read is put into the

 

 

 

 

 

corresponding array elements of the

 

 

 

 

 

data array based on which module

 

 

 

 

 

positions are read.

w

CLEAR COUNTERS

 

3

Only module positions specified get

 

 

 

 

 

affected by command.

w

SET TIME DELAY

 

3

The Modifier is specified in the CSV

 

 

 

 

 

file with the opto22_modifier1

 

 

 

 

 

parameter. The data (timeout) is

 

 

 

 

 

retrieved from the first element of the

w

INITIATE SQUARE WAVE

 

3

data array.

 

 

 

w

HIGH RESOLUTION SQUARE WAVE

 

3

 

 

w

RETRIGGER TIME DELAY

 

3

Only module positions specified get

 

 

 

 

 

affected by command.

w

GENERATE N PULSES

 

3

Only specified module positions get

FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042

Visit our website: www.fieldserver.com E-mail: support@fieldserver.com

Page 21

Image 23
Contents FS-8700-17 Optomux Table of Contents Optomux Driver Description Optomux System Driver Scope of SupplyFS-X40 Hardware ConnectionsData Arrays Configuring the FieldServer as a Optomux Driver ClientClient Side Nodes Client Side ConnectionsFieldServer Related Map Descriptor Parameters Client Side Map DescriptorsDriver Related Map Descriptor Parameters Bit, Packed Timing Parameters SET Time Delay Generate N Pulses Read and Average InputsRead Status Map Descriptor Example 1 Read on/off StatusDEVICE77STAT , Discinputs FS-8700-17 Optomux Driver Manual Read STATUS, Responsearr Map Descriptor Example 3 Command Response/Completion StatusDEVICE77STAT , Cntrposns Map Descriptor Example 4 Triggered ActionDEVICE77STAT , Anadata PULSE77 Timedata This example, module positions 1 and 5 are pulsedWrbc , DEV77 , 16 , 10.0s CLRLOW77 LowarrayConfiguring the FieldServer as a Optomux Server Module Positions Command Response StatusDriver Notes DataArrayName, DABitName, DAByteNameOptomux Commands FS-8700-17 Optomux Driver Manual Read Specified module positions get set Affected. The data period of pulses Only one module position may be Calculated and read. Data read gets Driver Stats Array Element ContentsRevision History