FieldServer FS-8704-49 instruction manual FS-8700-49DataAireDAP

Page 44

FS-8700-49_Data_Aire_DAP

 

 

Page 44 of 48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location in

Location in Data

 

 

 

 

 

 

 

Data Array

Array (Absolute

 

 

 

 

Byte

Bit

Relative

(Absolute

Offset) Each set

046, 048 and 049 Units

DAP 80 Units

 

 

 

 

Offset

Offset) Each

of 8 alarms

 

 

 

 

 

 

 

alarm stored as

stored as a

 

 

 

 

 

 

 

a separate bit

byte*

 

 

 

 

5

5

45

118

48:05

Custom message on

N/A

 

 

optional alarm input #1

 

 

 

 

 

 

 

 

 

 

5

6

46

119

48:06

Custom message on

N/A

 

 

optional alarm input #2

 

 

 

 

 

 

 

 

 

 

5

7

47

120

48:07

Custom message on

N/A

 

 

optional alarm input #3

 

 

 

 

 

 

 

 

 

 

6

0

48

121

49:00

Discharge air temperature

N/A

 

 

 

 

 

 

 

limit (just a condition)

 

 

 

 

 

 

 

 

Reheat mode during

 

 

 

6

1

49

122

49:01

dehumidification (just a

N/A

 

 

 

 

 

 

 

condition)

 

 

 

6

2

50

123

49:02

N/A

N/A

 

 

6

3

51

124

49:03

N/A

N/A

 

 

6

4

52

125

49:04

N/A

N/A

 

 

6

5

53

126

49:05

N/A

N/A

 

 

6

6

54

127

49:06

N/A

N/A

 

 

6

7

55

128

49:07

N/A

N/A

 

 

 

 

 

 

Notes

 

 

 

 

 

 

 

 

 

43:00 Indicates array

 

 

 

 

 

 

 

 

element zero. Individual

 

 

 

 

 

 

 

*

alarm can be found by

 

 

 

 

 

 

 

masking and looking at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the zero'th bit of this

 

 

 

 

 

 

 

 

element.

 

 

Chiller Stat Query

Unlike the Dap-Stat errors, these are stored in the Data Array using only one method – each error is stored at a separate location in the Data Array.

Location in Data Array

 

 

 

Relative

(Absolute Offset) Each alarm

Alarm / Bit Descriptions

Byte

Bit

stored as a separate bit

 

 

 

Offset

 

 

 

 

536

Auxiliary cooling available

0

0

0

537

Auxiliary cooling locked out

0

1

1

538

Unit on backup module standby

0

2

2

539

Custom message on optional input #1

0

3

3

540

Custom message on optional input #2

0

4

4

541

Evaporator freeze stat module #1

0

5

5

542

Evaporator freeze stat module #2

0

6

6

543

Evaporator freeze stat module #3

0

7

7

544

High pressure problem module #1

1

0

8

545

High pressure problem module #2

1

1

9

546

High pressure problem module #3

1

2

10

547

High return temperature warning

1

3

11

548

High supply temperature warning

1

4

12

549

Local alarm #1: See tag inside door

1

5

13

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.FieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2269 Toll_Free: 888-509-1970 email: support@FieldServer.com

Image 44
Contents FS-8704-49 Data Aire DAP Table of Contents Page Data Aire Description Performance Issues Dartiii onlyData Alarm Network Module Network LED Operation FS-8700-49DataAireDAP Hardware Connections ModelConfiguring the FieldServer as a Data Aire Client Data Arrays/DescriptorsClient Side Connection Descriptions DAPClient Side Node Descriptors Driver Related Map Descriptor Parameters Timing ParametersMap Descriptor Example 1 Everything Map Descriptor Example 2 Writing a Set-PointAdditional information is provided in Appendix B UnitType 185 499 855 908 Appendix A.2. Data Point Descriptions Runtimec1 Compressor 1 runtime DAP-Xtra All Adjrate Adjustment rate DAP Menu DAP049,048,046 DAP80 Dcalib Discharge Air sensor DAP80 Menu Valveconfig Chilled water Valve DAP80 Menu FS-8700-49DataAireDAP Appendix A.3. Data Unit Types FS-8700-49DataAireDAP Appendix B.2. DAFunc Parameter Permitted values Appendix B.3. DAField Parameter Permitted values4 Appendix B.4. DAMethod Parameter Values and NotesFS-8700-49DataAireDAPPage 29 DAAI1 Rdbc FS-8700-49DataAireDAPPage 31 INH04 DAWR01 Appendix C. Troubleshooting Tips Appendix C.1. Bad Values Appendix C.7. WiringAppendix C.2. Dead Nodes Appendix C.3. NoiseAppendix C.8. Stuck Unit Appendix C.9. Number of UnitsAppendix D. Error Messages Page Page Appendix D.1. Exposing Driver Statistics FYIPage Appendix E.2. Associated Map Descriptors Appendix E.4. DAP Unit Errors Appendix E.3. Starting/Stopping DAP devicesFS-8700-49DataAireDAP FS-8700-49DataAireDAP FS-8700-49DataAireDAP FS-8700-49DataAireDAP Dasetpoints Wrbc Appendix F. Write Through’s This page Intentionally Left Blank