Marathon Computer AACC 2000 manual Output list, CmS Comms list, InFo Information list

Page 42

Marathon Monitors Inc.

Name Description

oP

Output list

Does not appear if Motorised Valve control configured.

OP.Lo

 

Low power limit (%)

 

OP.Hi

 

High power limit (%)

 

OPrr

 

Output Rate Limit (% per sec)

 

FOP

 

Forced output level (%)

 

CYC.H

 

Heat cycle time (0.2S to 999.9S)

 

hYS.H

 

Heat hysteresis (display units)

 

ont.H

 

Heat output min. on-time (secs)

 

 

 

Auto (0.05S), or 0.1 - 999.9S

 

CYC.C

 

Cool cycle time (0.2S to 999.9S)

 

hYS.C

 

Cool hysteresis (display units)

 

ont.C

 

Cool output min. on-time (secs)

 

 

 

Auto (0.05S), or 0.1 - 999.9S

 

HC.db

 

Heat/cool deadband (display units)

 

Sb.OP

 

Sensor Break Output Power (%)

 

 

 

 

 

cmS

 

Comms list

 

Addr

 

Communications Address

 

 

 

 

inFo

Information list

 

diSP

Configure lower readout of Home display to show:

 

 

VPoS

Valve position

 

 

Std

Standard - display setpoint

 

 

AmPS

Load current in amps

 

 

OP

Output

 

 

Stat

Program status

 

 

PrG.t

Program time remaining in

hours

 

Li 2

Process value 2

 

 

rAt

Ratio setpoint

 

 

PrG

Selected program number

 

 

rSP

Remote setpoint

 

LoG.L

PV minimum

 

LoG.H

PV maximum

 

LoG.A

PV mean value

 

Log.t

Time PV above Threshold level

 

Log.v

PV Threshold for Timer Log

 

AACC 2000 Carbon

42

Nov. 1, 1997

 

 

Image 42
Contents Copyright Marathon Monitors INC Marathon Monitors Inc Mechanical Installation Cleaning SafetyElectrostatic discharge precautions Electromagnetic compatibilityPower Isolation Safety SymbolsWiring PersonnelVoltage rating Over-temperature protectionOvercurrent protection Conductive pollutionInstallation requirements for EMC Grounding of the temperature sensor shieldRouting of wires Environmental ratings Equipment ratingsElectrical safety GeneralMarathon Monitors Inc Installation Outline dimensions Model Outline dimensions Model 2000 controllerController labels To install the controllerIntroduction Unplugging and plugging-in the controllerRear terminal layouts Model Aacc 2000 rear terminal layoutMarathon Monitors Inc Sensor input connections Module 1, 2Two terminal modules SnubbersFour terminal modules COMDual output modules Connections for Process Value 3 in module position Connections for Process Value 2 PV2Communication module Wiring of 2-wire EIA-485 serial communications link EIA-485 wiringMarathon Monitors Inc Operation 26.0 Front Panel LAYOUTsOP2 Button or Name ExplanationOP1 SP2Alarms Basic operationOperating modes Home display Automatic modeOutput power demand Display unitsManual Mode SetpointParameters and HOW to Access Them List header displaysMarathon Monitors Inc Parameter names Parameter displaysTo change the value of a parameter List 1OFFOFF PID PID.1Fact STDPass Name Description Prob Probe list Process Factor Millivolt input OffsetHydrogen or CO constant Name Description DrA.t TunEDrA AdcRES Pid PID listSEt HcbSetpoint list Input listOutput list CmS Comms listInFo Information list Access List FF.OPAlarms Diagnostic alarms Display What it means What to do about it Shows2b Diagnostic alarms Access Levels Access list header Password entryAccess to Read-only Configuration Configuration password Configuration levelLevel selection Returning to Operator Level Setting operator access to a parameterEdit level Hiding or revealing a complete listPromoting a parameter This sheet intentionally left blank Tuning Parameter Code Meaning or FunctionOne-shot Tuning How to tuneTypical automatic tuning cycle Calculation of the cutback valuesAdaptive tune Manual Tuning Setting the cutback values Proceed as followsIntegral action and manual reset Automatic droop compensation AdcName Description Values Mtr Motor list Min Max Default Motorized valve controlAdjusting the minimum on-time ‘mp.t’ Inertia and backlash settingsMarathon Monitors Inc Enable in configuration level Gain schedulingSet the transfer point Configuration Selecting configuration level Press to enter configurationLeaving Configuration Level Changing the passwordsD1SA Enab REULIN SB.OPRely CMSNone DIG YESPMV H2O InSt Instrument configurationName Description Values Meaning SP.FFProcess value config Input configurationCJC Setpoint configuration VAL.LVAL.H Alarm configuration Values Table a Alarm types ValueAlarm Modes Digital input 1 configuration Action on contact closure Digital input 2 configuration Action on contact closureIMP Alarm relay configuration VfltPflt Comms 1 module config Combining several digital events on to one outputModule config 1A b C1 Module 1 configurationCool 2A/b/C Module 2 configuration For ‘id’ = ‘LoG.i’ i.e logic input use the LA Conf’ list onDisplayed value low 3A/b/C Module 3 configuration SELC Module configuration Module configurationPoint Custom Linearisation VAL.1VAL.8 CAL DC Output Calibration Password configurationExit Exit configuration User calibrationUser calibration User Calibration Enable User Calibration EnableCalibration Configuration List Exit configurationOffset calibration Input list headerCalibration type See table on the right for additional parameters Set OffsetTwo-point calibration Displayed ValueAdjust low-point calibration Select Low-point CalibrationAdjust High-point Calibration Select High-point CalibrationCalibration points and Calibration offsets Name Parameter description MeaningParameter Table Default HY1 Ssel FLT3 Marathon Monitors Inc AL1 Module 2A High Value VAL.1 101 Index Two-point calibration User calibration Aacc 2000 Carbon