I-Data ReRouter instruction manual Mode Table Local Remote

Page 32

Configuration ida ReRouter

MODE TABLE:

LOCAL

REMOTE

LOCAL

REMOTE

LOCAL

LOCAL 37XX

 

 

37XX

37XX

3174 TR

3174 TR

3172

TR

 

SDLC

SDLC/TR

GATEWAY GATEWAY ETHERNE

ATTACHMENT

 

 

 

 

 

T

 

 

 

 

 

 

GATEWAY

 

LOGMODE

IBM3820M

IBM3820R

IBM3820T

IBM3820R

IBM3820T

IBM3820T

FMPROF

X’13’

X’13’

X’13’

X’13’

X’13’

X’13’

TSPROF

X’07’

X’07’

X’07’

X’07’

X’07’

X’07’

PRIPROT

X’B0’

X’B0’

X’B0’

X’B0’

X’B0’

X’B0’

SECPROT

X’B0’

X’B0’

X’B0’

X’B0’

X’B0’

X’B0’

COMPROT

X’D0B1’

X’D0B1’

X’D0B1’

X’D0B1’

X’D0B1’

X’D0B1’

RUSIZES

X’B7B7’

X’8686’

X’8787’

X’8686’

X’8787’

X’8787’

PSNDPAC

X’03’

X’10’

X’10’

X’10’

X’10’

X’10’

SSNDPAC

X’00’

X’00’

X’00’

X’00’

X’00’

X’00’

SRCVPAC

X’03’

X’10’

X’10’

X’10’

X’10’

X’10’

PSERVIC

X’060200000000000000002000’

 

 

 

NOTE:

RUSIZES field is less than the VTAM major node MAXDATA parameter.

If using 3174, RUSIZES must match token ring address configuration (F) value.

PSERVIC is same for all configurations.

Example of VTAM PARAMETERS

Chapter 7: Workstation Configuration provides S/370 configuration worksheets for the remote devices - ida 913-03 Token Ring and ida PrintServer 13.

32

Image 32
Contents Data Electronic Documentation Main Office Preface JanuaryRelated Manuals Token Ring EthernetTable of Contents Table of Contents Ida ReRouter What is the ida ReRouter? IntroductionIda ReRouter in a Token Ring environment With connections to PCL 4/5 printers Product FeaturesIdaRCtrl Items Supplied with ida ReRouter Quick Guide D10276Personal Computer Requirements Product RequirementsHost System Requirements Installation of ida ReRouter Type a setupInstallation and Setup ida ReRouter Setup of ida ReRouter Description Route nameStatus New ChangeDelete VerifyDeActivate Route RefreshView Log Product InformationDefining a new route Enter DescriptionEnter Connect Timeout Communications ManagerValidation must be made in the configuration program Deleting a route Additional routesChanging a route Keep Alive Function Support for KeepAlive to OS/22 TCP/IP KeepAlive configuration on OS/2 1 PSF/MVS printer definition and startup procedure Configuration of S/370 NetworksConfiguration Examples for MVS and VM LUNAME=IDSNCEP0 2 PSF/VM PDM definition Disintv3 PSS/MVS printer definition and startup procedure PSS44 PSS/VM PDM definition Fssuser = PSS1 Userid OFF Virtual Machine Printing PSS printer profile using SNA and TCP/IP attachment Host Vtam definition PSFAPP11Mode Table Local Remote Prompts Parameter and values Parentheses Configuration of AS/400 NetworksCreating Appc device description Network Creating Printer Device DescriptionValue must be unique within Updating Appn Remote Location List SNA connections onlyRemote Location Name RER1 Remote Network Identifier DKIDTN01Control Point Network Identifier Remote Control Point NameLocal Location Name S4450327 Sample Controller Definition QlusFor SNA connection Workstation ConfigurationCommunications Manager/2 for S/370-390 and AS/400 Changing configuration file Communications Manager SetupSelect Configure Configuring Data Link Control DLC profilesSet Node type Configuring SNA local node characteristicsConfiguring SNA connection For S/370 host connection For AS/400 host connectionConfiguring SNA features Peer node connection normally AS/4003a. Select Activate at startup Connections ListSNA Features / Partner LU Select Partner LUs Creating a local LULU Alias must be the same as defined Ida ReRouterFor Ipds connection to PSF/370-390 and PSF/400 AS/400 onlyCreating a transaction program definition SNA Features List For Icds connection to ida PSSAdditional TP Parameters Communications Manager Profile List SheetCommunications Manager Configuration Def 2 S/370 Network Configuration Worksheet First device ida 913-03 Token RingSecond device ida PS 3 AS/400 Network Configuration Worksheet First device ida 913-03 Token Ring PartAPPCDev Printer Dev Configuration List Second device ida PS Part Partner LU Profile Explanation to Configuration Worksheets Node ID 370 S/390AS/400 TP nameLocal LU address Local LU nameLocal LU alias This parameter is for S/370 S/390 only This parameter is for AS/400 onlyLaps TCP/IPRouting Ping Testing Connection to Remote DevicePing Function Ping function succeeded Ping function failedLog Files Action Problem DeterminationError Syntax ROUT0035E Cannot open configuration file ROUT0052E Configuration error for entryROUT0105E Appc communication error ROUT0106E Appc allocation errorROUT0111E Appc error opcode ... Primary rc Secondary rc ROUT0602E Invalid connect timeout valueROUT0603E TCP/IP socket error ROUT0110E Invalid Appc opcodeProblem Determination ida ReRouter ROUT0613I Printer is not ready IRQ on remote printer ROUT0611I Trace enabledROUT0612W Swiddef file error ROUT0700E Internal software error ROUT0800E Semaphore handling errorROUT0801E Named Pipe handling error ROUT0802E Timer handling errorROUT0803E Thread handling error TraceList of Abbreviations PPD/PPRAppendix a Keyword Definitions SyntaxRoutename Keywordipaddress Appendix BFill-InConfigurationWorksheet WORK-STATION PSF Vtam NCP IDA Fill-In Configuration Worksheet for AS/400 Communications Appendix C i-data Products Mainframe environmentMidrange environment Readers Comments