I-Data ReRouter 3 AS/400 Network Configuration Worksheet, First device ida 913-03 Token Ring Part

Page 49

Workstation Configuration ida ReRouter

7.1.3 AS/400 Network Configuration Worksheet

This section provides details on the configuration worksheets for two remote devices connected to the ida ReRouter: the ida 913-03 Token Ring and the ida PS 13.

First device: ida 913-03 Token Ring - Part 1.

WORKSTATION:

Comm. Manager/2

LAPS

TR LINE

APPCController

1

Configuration filename

TOKENR

 

 

 

 

Token Ring DCL Profile

 

 

 

 

 

2

Adapter number

0

 

 

 

0

3

Max. link stations

2

 

 

 

 

4

Max.RU size

1024

 

1024

*CALC

5

C&SM LAN ID

IDATA1

 

 

 

 

Local Node Characteristics

 

 

 

 

 

6

Network name (ID)

DKIDTN01

 

 

 

DKIDTN01

7

Local node name

IDATA1

 

 

 

IDATA1

8

Local Node ID

05D 00000

 

 

 

05D 00000

 

Transaction Program Def.

 

 

 

 

 

9

TP name

$DPF

 

 

 

 

10

Program path / name

C:\IDAROUTE\IDAROUTE.EXE

 

 

 

 

Partner LU

 

 

 

 

 

11

Full PLU name

 

 

 

 

 

 

Partner network ID

DKIDTN01.

 

 

 

DKIDTN01.

 

Partner node name

S4450327

 

 

 

S4450327

Local LU

 

 

 

 

 

12

Local LU name

RER1

 

 

 

 

13

Local LU alias

MYALIAS

 

 

 

 

14

Local LU address

 

 

 

 

 

 

Connections

 

 

 

 

 

15

Destination address

40000B100002

 

 

40000B100002

 

16

LAN Adapter addr.

 

40005A0000D5

 

 

 

17

IP Address

 

 

 

 

 

18

Port No. .

 

 

 

 

 

Mode Profile

 

 

 

 

 

19

Mode name

QSPWTR

 

 

 

 

49

Image 49
Contents Data Electronic Documentation Main Office January PrefaceToken Ring Ethernet Related ManualsTable of Contents Table of Contents Ida ReRouter Introduction What is the ida ReRouter?Ida ReRouter in a Token Ring environment IdaRCtrl Product FeaturesWith connections to PCL 4/5 printers Quick Guide D10276 Items Supplied with ida ReRouterHost System Requirements Product RequirementsPersonal Computer Requirements Type a setup Installation of ida ReRouterInstallation and Setup ida ReRouter Setup of ida ReRouter Status Route nameDescription Change NewDelete VerifyRefresh DeActivate RouteView Log Product InformationEnter Description Defining a new routeCommunications Manager Enter Connect TimeoutValidation must be made in the configuration program Changing a route Additional routesDeleting a route Support for KeepAlive to OS/2 Keep Alive Function2 TCP/IP KeepAlive configuration on OS/2 Configuration Examples for MVS and VM Configuration of S/370 Networks1 PSF/MVS printer definition and startup procedure LUNAME=IDSNCEP0 Disintv 2 PSF/VM PDM definitionPSS4 3 PSS/MVS printer definition and startup procedure4 PSS/VM PDM definition Fssuser = PSS1 Userid OFF Virtual Machine Printing PSS printer profile using SNA and TCP/IP attachment PSFAPP11 Host Vtam definitionMode Table Local Remote Creating Appc device description Configuration of AS/400 NetworksPrompts Parameter and values Parentheses Value must be unique within Creating Printer Device DescriptionNetwork SNA connections only Updating Appn Remote Location ListRemote Location Name RER1 Remote Network Identifier DKIDTN01Local Location Name S4450327 Remote Control Point NameControl Point Network Identifier Qlus Sample Controller DefinitionCommunications Manager/2 for S/370-390 and AS/400 Workstation ConfigurationFor SNA connection Communications Manager Setup Changing configuration fileSelect Configure Configuring Data Link Control DLC profilesConfiguring SNA connection Configuring SNA local node characteristicsSet Node type For AS/400 host connection For S/370 host connectionPeer node connection normally AS/400 Configuring SNA features3a. Select Activate at startup Connections ListCreating a local LU SNA Features / Partner LU Select Partner LUsLU Alias must be the same as defined Ida ReRouterCreating a transaction program definition AS/400 onlyFor Ipds connection to PSF/370-390 and PSF/400 For Icds connection to ida PSS SNA Features ListAdditional TP Parameters Communications Manager Profile List SheetCommunications Manager Configuration Def First device ida 913-03 Token Ring 2 S/370 Network Configuration WorksheetSecond device ida PS First device ida 913-03 Token Ring Part 3 AS/400 Network Configuration WorksheetAPPCDev Printer Dev Configuration List Second device ida PS Part Partner LU Profile Explanation to Configuration Worksheets 370 S/390 Node IDAS/400 TP nameLocal LU alias Local LU nameLocal LU address This parameter is for AS/400 only This parameter is for S/370 S/390 onlyTCP/IP LapsRouting Ping Function Testing Connection to Remote DevicePing Ping function failed Ping function succeededLog Files Error Syntax Problem DeterminationAction ROUT0052E Configuration error for entry ROUT0035E Cannot open configuration fileROUT0105E Appc communication error ROUT0106E Appc allocation errorROUT0602E Invalid connect timeout value ROUT0111E Appc error opcode ... Primary rc Secondary rcROUT0603E TCP/IP socket error ROUT0110E Invalid Appc opcodeProblem Determination ida ReRouter ROUT0612W Swiddef file error ROUT0611I Trace enabledROUT0613I Printer is not ready IRQ on remote printer ROUT0800E Semaphore handling error ROUT0700E Internal software errorROUT0801E Named Pipe handling error ROUT0802E Timer handling errorTrace ROUT0803E Thread handling errorPPD/PPR List of AbbreviationsSyntax Appendix a Keyword DefinitionsRoutename Keywordipaddress Appendix BFill-InConfigurationWorksheet WORK-STATION PSF Vtam NCP IDA Fill-In Configuration Worksheet for AS/400 Communications Mainframe environment Appendix C i-data ProductsMidrange environment Readers Comments