Chatsworth Products RIM-600 user manual Operating Environment, Rack Mount Installation

Page 23

Chapter 1: Installation

Operating Environment

Before you install the RIM-600 Host be sure that your operating environment meets the physical requirements of the equipment.

Operating Temperature:

32º–122º Fahrenheit (0º–50º C)

Humidity:

5–90 %RH, non-condensing

Power:

90–260VAC 47/63 Hz outlet within 6'

Rack Requirements:

Standard 19" equipment rack with supplied mounting bracket

 

hardware. Requires 1.0 EIA rack mount space.

Tabletop requirements:

Flat area which can support an enclosure 17" wide by 10" deep by 2"

 

high.

Rack Mount Installation

The RIM-600 Host can be rack mounted using the included rack mount brackets. Follow the steps below:

1)Attach rack-mount brackets to the sides of the Host unit with a Phillips screwdriver.

2)Attach the unit to the equipment rack using two pan-head screws per side. Tighten the screws with a Phillips screwdriver.

3)Plug the power cord into a 90-260VAC outlet.

Figure 3: Rack-mounted Host Unit

Wall Mount Installation

The RIM-600 Host can be wall mounted using the optional wall mount brackets. Follow the steps below:

1)Attach the optional wall mount brackets to the sides of the RIM-600 using the eight black #6-32 screws. A Phillips screwdriver will be required. (Order part # 60075-001 Universal Wall Mount Kit)

2)Attach the unit to the wall using two screws per side. Tighten the screws with a Phillips screwdriver.

3)Plug the power cord into a 90-260VAC outlet.

23

Image 23
Contents Version Remote Infrastructure Management RIM-600Page Important Safety Instructions Chatsworth Products, Inc Industrial Drive New Bern, NC Fax FCC RequirementsGeneral Requirements for all Automatic Dialers Host only Telephone Consumer Protection Act Host onlyRIM-600 Manual Year Limited Warranty Chatsworth Products, Inc Industrial Drive New Bern, NC Fax Table of Contents RIM-600 Quick Start Guide RIM-600 SoftwareAlarm Logic Software InstallationConfiguring Hosts and Nodes Setting Up An Enterprise Configuring Templates Configuring IP Alarms IP Alarm SetupWeb Configuring User Profiles and Contacts Adding a ProfileHoliday Setup Alarm Message Pop-Ups Deleting a Profile Contacts Adding ContactsCommunicating with your RIM-600 Snmp Simple Network Management ProtocolGraphs PowerGate2 Setup via the RIM-600 ConsoleView Software PowerGatePowerGate2 RIM-600 PowerGate Specifications Operating SpecificationsRIM-600 Sensors Water Detection Sensor External Power SensorRoom Humidity Sensor Room Humidity Sensor with displayPassive Infrared Detection Sensor Door SwitchDry Contact Bridge 60051-001 4-20mA BridgeTechnical Support for the RIM-600 Sensors Smoke Detector SensorTechnical Support FeaturesIntroduction Front Panel Layout Host Installation and ConfigurationAbout This Manual Physical DescriptionSensor Inputs Rear Panel InstallationAC Power and Battery LEDs ON/OFF SwitchOperating Environment Rack Mount InstallationWall Mount Installation Connecting Sensors Tabletop InstallationPower On Self Test Post Network Configuration Enterprise Status Unit Type IP Return to main menu Local Configuration Definitions Replacing the Battery Battery MaintenanceRIM-600 Manual Environmental Monitoring RIM-600 Host SpecificationsOperating Specifications Communications SpecificationsMicrophone Node Installation & ConfigurationBattery Compartment Battery replacement in the Node unit Battery ReplacementWall-mounted Node Unit RIM-600 Node Unit Local Configuration Definitions Node Specifications RIM-600 Quick Start Guide Install Units and Configure Network SettingsInstall Software and Log In to Host Default Username and PasswordConnect Environmental Sensors to Host and Nodes Configure the Unit Properties for the Host and NodesConfigure Input Templates Record and Assign Voice Messages Configure User Profiles and ContactsConfigure IP Alarms Hardware and Software Requirements Software Installation and Hardware RequirementsSoftware Installation Installing from the CDStarting the RIM-600 ConsoleView Software Configuring Hosts and NodesSetting Up An Enterprise Adding an Enterprise Group Connecting to a HostAdding a Host Deleting a HostSystem Info tab Setting the Unit Properties for the RIM-600 HostAdding a Node Clock settings tabDeleting a Node Changing Host Network Settings using ConsoleViewSetting the Unit Properties for the Node Node Properties Setup Tab Changing Node Network SettingsChannel Setup Configuring Environmental InputsEditing the schedule Channel Setup screenAlarm Class dropdown menu Camera Snapshots on Alarm Alarm Response via the PowerGate, PowerGate2, or CameraRealtime Strip Chart High Sound AlarmsRemoving/Changing a Sensor Environmental Input Alarm LogicTrouble Alarms Configuring TemplatesTemplate Types Programming Alarm Parameters Configuring IP AlarmsIP Alarm Setup IP Schedule screen Alarm Logic IP Alarm Flowchart Removing an IP AlarmSetup Classes Input/Alarm ClassesAdding a Profile Configuring User Profiles and ContactsConfiguring User Profiles Permissions Master System Site Admin UserSelecting Classes ClassesAdding Contacts ContactsDeleting a Profile Alphanumeric Pager Calls Voice CallsNumeric Pager Calls Schedule Alarm Delivery OptionsFax Calls MailRecording Voice Messages ReconnectingSaving and Loading Programming Recording and Uploading Voice MessagesCustom Voice Manager Holiday List Holiday SetupEnabling Custom Pop-Up Messages Alarm Message Pop-UpsActivating Alarm Pop-Ups Editing Pop-Up Custom Message Setting Pop-Up Text LocationAudible Alarm Notification Smtp Error messages Mail Setup and Two-Way E-Mail CommandsRequesting a Trace Route Two Way E-MailRequesting a Status Report Requesting an IP PingRequesting Help Requesting a PowerGate Outlet CommandRequesting a Picture from a Camera Panasonic Configuring a Video CameraAssociating Cameras Graphs WebRemote Web Updating the WebViewing the Remote Web HistoryHistory Options Datalog HistoryQuerying the History Database with HistoryView Viewing HistoryHistory QuickView Printing Data Exporting Data GraphingArchiving Manually Forcing History DownloadsCopying to the Clipboard Deleting DataManual Datalog Download in progress Updating Firmware

RIM-600 specifications

Chatsworth Products (CPI) has established a reputation for delivering innovative solutions in the field of infrastructure technology. One of their standout products is the RIM-600, a versatile and feature-rich telecommunications rack designed to accommodate various IT equipment needs in data centers and network environments.

The RIM-600 boasts a robust construction, featuring a sturdy steel framework that enhances durability and provides optimal protection for sensitive electronic components. This product is engineered to support a range of IT gear, including servers, network switches, and patch panels, making it an ideal choice for organizations looking to maximize their data center efficiency.

One of the key features of the RIM-600 is its impressive cooling capability. The rack is designed with advanced airflow management in mind. It includes adjustable vertical cable management options that help maintain proper airflow while minimizing cable congestion. This design is crucial for preventing overheating and ensuring reliable performance for all housed equipment, thereby extending the lifespan of critical hardware.

The RIM-600 also incorporates tool-less assembly, simplifying the installation and setup process. This feature is particularly advantageous for IT professionals who require a rapid deployment of systems without cumbersome installation procedures. Furthermore, the rack’s modular design allows for easy customization and scalability, accommodating varying configurations as business needs evolve.

Moreover, the RIM-600 ensures enhanced accessibility with removable side panels and rear doors. This facilitates hassle-free cable access and promotes efficient maintenance practices. The inclusion of integrated grounding provisions ensures that all equipment remains secure and compliant with safety standards.

In terms of scalability, the RIM-600 can support up to 3,000 pounds of equipment, offering ample weight capacity for heavy-duty installations. Its compatibility with popular accessories, including shelving, power distribution units, and cooling solutions, further enhances the rack's utility and flexibility in diverse operational environments.

In summary, the Chatsworth Products RIM-600 is an exceptional telecommunications rack combining durability, cooling efficiency, and ease of installation. Its innovative design and thoughtful features make it a top choice for organizations looking to elevate their data center infrastructure while ensuring equipment protection and optimal performance.