Another benefit of using RJ-45 connectors is that you can easily locate sensors at distant locations within your facility by using your existing structured cabling. For example: Suppose you have an RIM-600 installed in room A and you want to install a sensor in room B. If your existing cabling infrastructure has an unused cable path between room A and room B, then you simply use an RJ-45 interconnect cable to connect the RIM-600 to the patch panel in room A, and an RJ-45 interconnect cable from the wall jack in room B to the sensor.

CAUTION: The sensor produces an analog signal which must connect directly to the Host or Node. The path from the sensor to the RIM-600 unit CANNOT pass through a network Hub or Switch.

Network Configuration

The RIM-600 Host has a serial port on the front panel which is used to configure network settings and security options. A dumb terminal or terminal emulation software is required to get online and set up the configuration. The port is male DTE, so you will need to use a null modem cable. Terminal communication settings must be set to:

n 9600 baud, no parity, 8 data bits, 1 stop bit

To get online with the RIM-600, connect your terminal to the serial port and press <RETURN>. A menu will appear which will guide you through the setup.

RIM-600 Host Unit V1.0.0.0

Enter Password ()>

{The DEFAULT PASSWORD for a New Unit is “rim600”}

1.Display Enterprise status

2.Display Network and Option configuration

3.Configure Network settings

4.Configure Enterprise Name

5.Configure Web Server

6.Configure Remote Access Server

7.Enable Two-Way E-mail Responder

8.Enable Microphone Listen-In

9.Enable default Master Administrator Account (temporarily)

0.Enable data modem A. Configure SNMP

B. Change Admin Password

C. Reset To Factory Defaults D. Display Statistics

E. Reboot F. Logout Enter option->

If you select Option 1 you will see the IP address and status of the Host and all associated nodes. A sample is shown below:

25

Image 25
Contents Version Remote Infrastructure Management RIM-600Page Important Safety Instructions Chatsworth Products, Inc Industrial Drive New Bern, NC Fax FCC RequirementsGeneral Requirements for all Automatic Dialers Host only Telephone Consumer Protection Act Host onlyRIM-600 Manual Year Limited Warranty Chatsworth Products, Inc Industrial Drive New Bern, NC Fax Table of Contents RIM-600 Quick Start Guide RIM-600 SoftwareConfiguring Hosts and Nodes Setting Up An Enterprise Software InstallationConfiguring Templates Configuring IP Alarms IP Alarm Setup Alarm LogicHoliday Setup Alarm Message Pop-Ups Configuring User Profiles and Contacts Adding a ProfileDeleting a Profile Contacts Adding Contacts WebGraphs Snmp Simple Network Management ProtocolCommunicating with your RIM-600 PowerGate2 PowerGateRIM-600 PowerGate Specifications Operating Specifications PowerGate2 Setup via the RIM-600 ConsoleView SoftwareRIM-600 Sensors Room Humidity Sensor External Power SensorRoom Humidity Sensor with display Water Detection SensorDry Contact Bridge Door Switch60051-001 4-20mA Bridge Passive Infrared Detection SensorTechnical Support for the RIM-600 Sensors Smoke Detector SensorIntroduction FeaturesTechnical Support About This Manual Host Installation and ConfigurationPhysical Description Front Panel LayoutSensor Inputs AC Power and Battery LEDs InstallationON/OFF Switch Rear PanelWall Mount Installation Rack Mount InstallationOperating Environment Power On Self Test Post Tabletop InstallationConnecting Sensors Network Configuration Enterprise Status Unit Type IP Return to main menu Local Configuration Definitions Replacing the Battery Battery MaintenanceRIM-600 Manual Operating Specifications RIM-600 Host SpecificationsCommunications Specifications Environmental MonitoringMicrophone Node Installation & ConfigurationBattery Compartment Battery replacement in the Node unit Battery ReplacementWall-mounted Node Unit RIM-600 Node Unit Local Configuration Definitions Node Specifications Install Software and Log In to Host Install Units and Configure Network SettingsDefault Username and Password RIM-600 Quick Start GuideConfigure Input Templates Configure the Unit Properties for the Host and NodesConnect Environmental Sensors to Host and Nodes Configure IP Alarms Configure User Profiles and ContactsRecord and Assign Voice Messages Software Installation Software Installation and Hardware RequirementsInstalling from the CD Hardware and Software RequirementsSetting Up An Enterprise Configuring Hosts and NodesStarting the RIM-600 ConsoleView Software Adding a Host Connecting to a HostDeleting a Host Adding an Enterprise GroupSystem Info tab Setting the Unit Properties for the RIM-600 HostAdding a Node Clock settings tabSetting the Unit Properties for the Node Changing Host Network Settings using ConsoleViewDeleting a Node Node Properties Setup Tab Changing Node Network SettingsChannel Setup Configuring Environmental InputsEditing the schedule Channel Setup screenAlarm Class dropdown menu Camera Snapshots on Alarm Alarm Response via the PowerGate, PowerGate2, or CameraRealtime Strip Chart High Sound AlarmsTrouble Alarms Environmental Input Alarm LogicConfiguring Templates Removing/Changing a SensorTemplate Types IP Alarm Setup Configuring IP AlarmsProgramming Alarm Parameters IP Schedule screen Alarm Logic IP Alarm Flowchart Removing an IP AlarmSetup Classes Input/Alarm ClassesConfiguring User Profiles Configuring User Profiles and ContactsAdding a Profile Permissions Master System Site Admin UserSelecting Classes ClassesDeleting a Profile ContactsAdding Contacts Numeric Pager Calls Voice CallsAlphanumeric Pager Calls Fax Calls Alarm Delivery OptionsMail ScheduleSaving and Loading Programming ReconnectingRecording and Uploading Voice Messages Recording Voice MessagesCustom Voice Manager Holiday List Holiday SetupActivating Alarm Pop-Ups Alarm Message Pop-UpsEnabling Custom Pop-Up Messages Audible Alarm Notification Setting Pop-Up Text LocationEditing Pop-Up Custom Message Smtp Error messages Mail Setup and Two-Way E-Mail CommandsRequesting a Status Report Two Way E-MailRequesting an IP Ping Requesting a Trace RouteRequesting a Picture from a Camera Requesting a PowerGate Outlet CommandRequesting Help Panasonic Configuring a Video CameraAssociating Cameras Graphs WebRemote Web Updating the WebViewing the Remote Web HistoryHistory Options Datalog HistoryHistory QuickView Viewing HistoryQuerying the History Database with HistoryView Printing Data Exporting Data GraphingCopying to the Clipboard Manually Forcing History DownloadsDeleting Data ArchivingManual Datalog Download in progress Updating Firmware

RIM-600 specifications

Chatsworth Products (CPI) has established a reputation for delivering innovative solutions in the field of infrastructure technology. One of their standout products is the RIM-600, a versatile and feature-rich telecommunications rack designed to accommodate various IT equipment needs in data centers and network environments.

The RIM-600 boasts a robust construction, featuring a sturdy steel framework that enhances durability and provides optimal protection for sensitive electronic components. This product is engineered to support a range of IT gear, including servers, network switches, and patch panels, making it an ideal choice for organizations looking to maximize their data center efficiency.

One of the key features of the RIM-600 is its impressive cooling capability. The rack is designed with advanced airflow management in mind. It includes adjustable vertical cable management options that help maintain proper airflow while minimizing cable congestion. This design is crucial for preventing overheating and ensuring reliable performance for all housed equipment, thereby extending the lifespan of critical hardware.

The RIM-600 also incorporates tool-less assembly, simplifying the installation and setup process. This feature is particularly advantageous for IT professionals who require a rapid deployment of systems without cumbersome installation procedures. Furthermore, the rack’s modular design allows for easy customization and scalability, accommodating varying configurations as business needs evolve.

Moreover, the RIM-600 ensures enhanced accessibility with removable side panels and rear doors. This facilitates hassle-free cable access and promotes efficient maintenance practices. The inclusion of integrated grounding provisions ensures that all equipment remains secure and compliant with safety standards.

In terms of scalability, the RIM-600 can support up to 3,000 pounds of equipment, offering ample weight capacity for heavy-duty installations. Its compatibility with popular accessories, including shelving, power distribution units, and cooling solutions, further enhances the rack's utility and flexibility in diverse operational environments.

In summary, the Chatsworth Products RIM-600 is an exceptional telecommunications rack combining durability, cooling efficiency, and ease of installation. Its innovative design and thoughtful features make it a top choice for organizations looking to elevate their data center infrastructure while ensuring equipment protection and optimal performance.