Chatsworth Products RIM-600 Room Humidity Sensor with display, Water Detection Sensor

Page 16

RIM-600 Manual

Electrical box installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Hidden cable surface installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Visible cable surface installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Sensor Template (factory default) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118

60030-001 Room Humidity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Electrical box installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Hidden cable surface installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Visible cable surface installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Sensor Template (factory default) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

60031-001 Room Humidity Sensor with display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Electrical box installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Hidden cable surface installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Visible cable surface installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Sensor Template (factory default) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124

60032-010 Water Detection Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125

Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Extending the WaterRope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Cascading Water Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Sensor Template (factory default) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127

60040-001 External Power Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128

Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128

xvi

Image 16
Contents Remote Infrastructure Management RIM-600 VersionPage Important Safety Instructions FCC Requirements Chatsworth Products, Inc Industrial Drive New Bern, NC FaxTelephone Consumer Protection Act Host only General Requirements for all Automatic Dialers Host onlyRIM-600 Manual Year Limited Warranty Chatsworth Products, Inc Industrial Drive New Bern, NC Fax Table of Contents RIM-600 Software RIM-600 Quick Start GuideSoftware Installation Configuring Hosts and Nodes Setting Up An EnterpriseConfiguring Templates Configuring IP Alarms IP Alarm Setup Alarm LogicConfiguring User Profiles and Contacts Adding a Profile Holiday Setup Alarm Message Pop-UpsDeleting a Profile Contacts Adding Contacts WebGraphs Snmp Simple Network Management ProtocolCommunicating with your RIM-600 PowerGate PowerGate2RIM-600 PowerGate Specifications Operating Specifications PowerGate2 Setup via the RIM-600 ConsoleView SoftwareRIM-600 Sensors External Power Sensor Room Humidity SensorRoom Humidity Sensor with display Water Detection SensorDoor Switch Dry Contact Bridge60051-001 4-20mA Bridge Passive Infrared Detection SensorSmoke Detector Sensor Technical Support for the RIM-600 SensorsIntroduction FeaturesTechnical Support Host Installation and Configuration About This ManualPhysical Description Front Panel LayoutSensor Inputs Installation AC Power and Battery LEDsON/OFF Switch Rear PanelWall Mount Installation Rack Mount InstallationOperating Environment Power On Self Test Post Tabletop InstallationConnecting Sensors Network Configuration Enterprise Status Unit Type IP Return to main menu Local Configuration Definitions Battery Maintenance Replacing the BatteryRIM-600 Manual RIM-600 Host Specifications Operating SpecificationsCommunications Specifications Environmental MonitoringNode Installation & Configuration MicrophoneBattery Compartment Battery Replacement Battery replacement in the Node unitWall-mounted Node Unit RIM-600 Node Unit Local Configuration Definitions Node Specifications Install Units and Configure Network Settings Install Software and Log In to HostDefault Username and Password RIM-600 Quick Start GuideConfigure Input Templates Configure the Unit Properties for the Host and NodesConnect Environmental Sensors to Host and Nodes Configure IP Alarms Configure User Profiles and ContactsRecord and Assign Voice Messages Software Installation and Hardware Requirements Software InstallationInstalling from the CD Hardware and Software RequirementsSetting Up An Enterprise Configuring Hosts and NodesStarting the RIM-600 ConsoleView Software Connecting to a Host Adding a HostDeleting a Host Adding an Enterprise GroupSetting the Unit Properties for the RIM-600 Host System Info tabClock settings tab Adding a NodeSetting the Unit Properties for the Node Changing Host Network Settings using ConsoleViewDeleting a Node Changing Node Network Settings Node Properties Setup TabConfiguring Environmental Inputs Channel SetupChannel Setup screen Editing the scheduleAlarm Class dropdown menu Alarm Response via the PowerGate, PowerGate2, or Camera Camera Snapshots on AlarmHigh Sound Alarms Realtime Strip ChartEnvironmental Input Alarm Logic Trouble AlarmsConfiguring Templates Removing/Changing a SensorTemplate Types IP Alarm Setup Configuring IP AlarmsProgramming Alarm Parameters IP Schedule screen Alarm Logic Removing an IP Alarm IP Alarm FlowchartInput/Alarm Classes Setup ClassesConfiguring User Profiles Configuring User Profiles and ContactsAdding a Profile Master System Site Admin User PermissionsClasses Selecting ClassesDeleting a Profile ContactsAdding Contacts Numeric Pager Calls Voice CallsAlphanumeric Pager Calls Alarm Delivery Options Fax CallsMail ScheduleReconnecting Saving and Loading ProgrammingRecording and Uploading Voice Messages Recording Voice MessagesCustom Voice Manager Holiday Setup Holiday ListActivating Alarm Pop-Ups Alarm Message Pop-UpsEnabling Custom Pop-Up Messages Audible Alarm Notification Setting Pop-Up Text LocationEditing Pop-Up Custom Message Mail Setup and Two-Way E-Mail Commands Smtp Error messagesTwo Way E-Mail Requesting a Status ReportRequesting an IP Ping Requesting a Trace RouteRequesting a Picture from a Camera Requesting a PowerGate Outlet CommandRequesting Help Configuring a Video Camera PanasonicAssociating Cameras Web GraphsUpdating the Web Remote WebHistory Viewing the Remote WebDatalog History History OptionsHistory QuickView Viewing HistoryQuerying the History Database with HistoryView Graphing Printing Data Exporting DataManually Forcing History Downloads Copying to the ClipboardDeleting Data ArchivingUpdating Firmware Manual Datalog Download in progress

RIM-600 specifications

Chatsworth Products (CPI) has established a reputation for delivering innovative solutions in the field of infrastructure technology. One of their standout products is the RIM-600, a versatile and feature-rich telecommunications rack designed to accommodate various IT equipment needs in data centers and network environments.

The RIM-600 boasts a robust construction, featuring a sturdy steel framework that enhances durability and provides optimal protection for sensitive electronic components. This product is engineered to support a range of IT gear, including servers, network switches, and patch panels, making it an ideal choice for organizations looking to maximize their data center efficiency.

One of the key features of the RIM-600 is its impressive cooling capability. The rack is designed with advanced airflow management in mind. It includes adjustable vertical cable management options that help maintain proper airflow while minimizing cable congestion. This design is crucial for preventing overheating and ensuring reliable performance for all housed equipment, thereby extending the lifespan of critical hardware.

The RIM-600 also incorporates tool-less assembly, simplifying the installation and setup process. This feature is particularly advantageous for IT professionals who require a rapid deployment of systems without cumbersome installation procedures. Furthermore, the rack’s modular design allows for easy customization and scalability, accommodating varying configurations as business needs evolve.

Moreover, the RIM-600 ensures enhanced accessibility with removable side panels and rear doors. This facilitates hassle-free cable access and promotes efficient maintenance practices. The inclusion of integrated grounding provisions ensures that all equipment remains secure and compliant with safety standards.

In terms of scalability, the RIM-600 can support up to 3,000 pounds of equipment, offering ample weight capacity for heavy-duty installations. Its compatibility with popular accessories, including shelving, power distribution units, and cooling solutions, further enhances the rack's utility and flexibility in diverse operational environments.

In summary, the Chatsworth Products RIM-600 is an exceptional telecommunications rack combining durability, cooling efficiency, and ease of installation. Its innovative design and thoughtful features make it a top choice for organizations looking to elevate their data center infrastructure while ensuring equipment protection and optimal performance.