AMCC 9550SX-8LP manual LED Indicator Pin Positions

Page 24

Chapter 1. Installing an AMCC 3ware 9550SX RAID Controller

Table 1 summarizes the LED indicator pin positions for the different controllers.

Warning: If using a chassis that has a common or shared LED ground, be sure to only connect LED cables to the anode pins on the controller. Do not connect any common ground to any cathode pins on the controller.

Table 1: LED Indicator Pin Positions

Controller

LED

Pin Pair

Comment

Header

 

 

 

 

 

 

 

9550SX-4LP

J7

: : : : :

Orientation Horizontal

 

 

0 1 2 3 All

Port number/All

 

 

 

(all activity indicator)

 

 

k-cathode-minus is on the top

 

 

a-anode-plus is on the bottom

 

 

 

 

9550SX-8LP

J7

: : : : :

Orientation Horizontal

 

 

0 1 2 3 All

Port number/All

 

 

 

(all activity indicator)

 

J8

: : : : :

Orientation Horizontal

 

 

4 5 6 7 All

Port number / NU

 

 

 

(Not Used)

 

 

k-cathode-minus is on the top

 

 

a-anode-plus is on the bottom

 

 

 

9550SX-12/12MI J7

: : : : :

Orientation Horizontal

 

 

0 1 2 3 All

Port number/NU (Not Used)

 

J8

: : : : :

Orientation Horizontal

 

 

4 5 6 7 All

Port number/NU (Not

 

 

 

Used)

 

J9

: : : : :

Orientation Horizontal

 

 

8 9 10 11 All

Port number/All (all activity

 

 

 

indicator)

 

 

k-cathode-minus is on the top

 

 

a-anode-plus is on the bottom

 

 

 

 

203ware 9550SX Serial ATA RAID Controller Quick Install Guide

Image 24
Contents 3ware Copyright TrademarksDisclaimer Table of Contents Appendix Technical Support Contents of Package Before You BeginInstallation Considerations Other DocumentationWhether to Use the LED Status Connector Safety Factors Personal SafetyWhat You Need Tools and Equipment Protecting Equipment and Data 9550SX 8-Port with Standard Sata Connectors 9550SX RAID Controller Cards9550SX 4-Port with Standard Sata Connectors 9550SX 12-Port with Standard Sata Connectors9550SX 12-Port with Multilane Internal Sata Connectors 9550SX 16-Port with Multilane Internal Sata ConnectorsInstalling a Serial ATA RAID Controller To connect Sata cables to the controllerTo install the controller in the computer Sata Cables Being Inserted Into PortInserting Controller Into PCI Slot Sata Cable Connecting to Drive To connect the Sata cables to the drives9550SX-12MI Multilane Serial ATA Cable InfiniBand 4x, SFF-84709550SX-16ML Multilane Cable Serial ATA SFF-8087Page To install the drives Connecting Drive Activity LED Indicators LED connector detailsPort 3ware 9550SX-12 Serial ATA RAID Controller Additional Details About the LED Status Connectors LED Indicator Pin Positions Check Installation and Close the Case Configure your RAID ArraysFinishing Up Installing an Amcc 3ware 9550SX RAID Controller Installing the Battery Backup Unit Installation Overview Tools and equipment requiredPoints of connection on the half-height controller Installation Instructions Removing the head from the plastic postPress down gently until the BBU is seated If you have a 4-port or 8-port 9550SX If you have a 12-port or 16-port 9550SX Shows the BBU fully installed on 3ware controllers BBU installed on controllers Replacing the Battery Removing the battery module Removing the power cable from the BBU module Sales and ordering information Feedback on this manualAppendix Technical Support